FPFabien Pointurier

Fabien Pointurier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fabien Pointurier has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of direct simultaneous uranium isotopic determination and age dating of micrometer-sized uranium particles by laser ablation – multi-collector ICPMS

    by Anne-Claire Humbert, Fabien Pointurier, Amélie Hubert

    In this study, we demonstrate that it is possible to simultaneously determine accurate uranium 234U and 235U abundances and the date of purification (or “age”) of uranium oxide materials at the particle scale using laser ablation – multi-collector ICPMS coupling. The method was successfully applied to microparticles of uranium materials enriched at 5%, 85% and 90% and purified 70 years ago. The deviations from the reference age are, at most, respectively 6 years, 2 years and 1 month which is comparable to what can be obtained using the reference technique LG-SIMS. The precision of 235U abundances and 234U abundances, at the particle scale, was respectively between 0.11% and 1.95% and between 0.4% and 5% which is equivalent to or better than what was previously published for the analyses of depleted to moderately enriched materials by LA-ICPMS, showing that adding 230Th determination doesn't degrade the determination of 234U and 235U abundances. Due to the small amount of material introduced into the ICPMS, μm-sized particle analysis by LA-ICPMS has the advantage of being less subject to laser-induced fractionation than bulk material analyses by LA-ICPMS. In contrast to the latter, a correction for uranium versus thorium fractionation can be applied based on the measurement of their relative sensitivities in standard solutions.


  • Open Access

    An isotope dilution mass spectrometry overview: tips and applications for the measurement of radionuclides

    by Alexandre Quemet, Amélie Hubert, Alkiviadis Gourgiotis, Ana María Sánchez Hernández, Marielle Crozet, Guillaume Bailly, Andrew Dobney, Georges Duhamel, Joe Hiess, Urska Repinc, et al.

    A useful guide and a critical review of the applications of ID-MS to radionuclide measurement is provided.


  • Comparison of the fluctuations of the signals measured by ICP-MS after laser ablation of powdered geological materials prepared by four methods

    by Michaël Susset, Axelle Leduc--Gauthier, Anne-Claire Humbert, Fabien Pointurier, Christophe Pécheyran

    Sample preparation is a crucial point for quantitative multi-elemental analses by LA-ICP-MS of powdered geological materials. Four different methods are compared in this study with respect to signal stability and intensity as follows: the preparation of glass beads (GlassB) by alkaline fusion method and three grinding and pelletizing methods relying on the use of an organic binder (VanBind, vanillic acid), an adhesive binder (MixGlue, methyl methacrylate) and a sol–gel process for glass formation (SolGel, chemical reaction of tetraethoxysilane), respectively. Sixty elements were analyzed by means of a ns-UV (213 nm) laser ablation system coupled to a single collector sector field ICP-MS with a low or medium mass resolution. Signal stability was found to strongly depend on the sample homogeneity provided by the preparation method. These methods were applied to three geological standard materials (CRM). The following criteria were used to evaluate and compare the methods: (1) proportion of the measurement cycles which are above a given signal intensity threshold (defined here as signal average ± 3 times the standard deviation), (2) signal stability of the analyzed nuclides (internal precision estimated by the relative standard deviations on raw count rates), (3) signal stability of the internal standards added to the samples, (4) external precision estimated by the relative standard deviation over five preparations for each geological CRM. For the majority of the analyzed elements, signals measured for samples prepared with the four methods are reproducible. Specific contamination in one or several elements (Cr, Fe, Co, Ni, Cu, Mo, W, Au and Bi) was observed depending on the sample preparation method. In addition, compared to grinding made with PTFE material, grinding performed with tungsten carbide material was found to produce better homogeneity, especially for the sol–gel and mixing with glue protocols, although some metallic contamination (W and Co) was observed. Thanks to the suppression of grain effects by alkaline melting, the glass bead method systematically provided signal stability and percentage of “over the threshold” close to those of the NIST glasses. This may be explained by the preparation of more homogeneous samples by alkaline melting. Finally, the described methods were found to be reproducible for the majority of the analyzed elements. Graphical abstract


  • Comparison of techniques to localise U-bearing particles in environmental samples

    by Aurélie Diacre, Pascal Fichet, Paul Sardini, Jérôme Donnard, Anne-Laure Fauré, Olivier Marie, Katsumi Shozugawa, Michaël Susset, Mayumi Hori, Takizawa Tsutomu, et al.


  • Determination of the isotopic composition of single sub‐micrometer‐sized uranium particles by laser ablation coupled with multi‐collector inductively coupled plasma mass spectrometry

    by Anne‐Laure Ronzani, Amélie Hubert, Fabien Pointurier, Olivier Marie, Nicolas Clavier, Anne‐Claire Humbert, Jean Aupiais, Nicolas Dacheux

    Rationale: A multi‐collector inductively coupled plasma (MC‐ICP) mass spectrometer coupled to a UV ns‐laser ablation (LA) system was used to measure uranium isotopic ratios ( 234 U/ 238 U, 235 U/ 238 U and 236 U/ 238 U) in single uranium particles of various sizes and isotopic compositions, including home‐made sub‐micrometric natural uranium particles of narrow size distribution (415 ± 60 nm). Methods: The LA‐ICP mass spectrometer was operated in wet plasma conditions thanks to simultaneous injection of the laser aerosol and water vapor through a desolvating nebulizer. The isotopic ratios were corrected for mass bias and gain factors between detectors. The 236 U/ 238 U ratios were also corrected for the presence of 235 U hydrides and tailing of the 238 U + peak. Results: 236 U/ 238 U ratios were successfully measured in micrometer‐sized particles from the NBS U050 certified standard material with a 236 U/ 238 U ratio of ~5 × 10 −4 . The analysis of 77 natural uranium sub‐μm‐sized particles yielded a very good trueness with respect to the expected 234 U/ 238 U and 235 U/ 238 U ratios, while the measurement errors for single particles ranged from −2.7% to +2.1% for 235 U/ 238 U and from −17% to +33% for the 234 U/ 238 U ratios. Their relative combined standard uncertainties ranged from 3.3% to 32.8% and from 0.4% to 4.0% for 234 U/ 238 U and 235 U/ 238 U ratios, respectively. In addition, extremely low detection limits, in the attogram range, were achieved. Conclusions: This study demonstrates that coupling of a ns‐laser ablation system with a MC‐ICP mass spectrometer allows measurements of the isotopic composition in natural uranium particles of a few hundreds of nm with very good trueness, average combined standard uncertainties of ~1% for 235 U/ 238 U ratios and 12% for 234 U/ 238 U ratios, and detections limits of a few ag for minor isotopes.


  • Capabilities of laser ablation – ICP-TOF-MS coupling for isotopic analysis of individual uranium micrometric particles

    by Anne-Laure Ronzani, Fabien Pointurier, Martin Rittner, Olga Borovinskaya, Martin Tanner, Amélie Hubert, Anne-Claire Humbert, Jean Aupiais, Nicolas Dacheux

    Capabilities of laser ablation coupled to a time of flight ICP-MS (‘icpTOF’, Tofwerk) for direct isotopic analysis of U micrometric reference particles deposited on carbon disks were demonstrated. Thanks to the very high temporal resolution which allows quasi simultaneous measurement of all nuclides, the icpTOF is well-suited for the acquisition of the very short transient signals produced by laser ablation of μm-sized particles. With appropriate corrections of the background due to high peak tailing of the 238U isotope and selection of signals within the detector's linear range, excellent internal and external precisions (0.2–0.4%) for measurement of the 235U/238U ratios were obtained in the most favorable cases (same abundances for the two isotopes). These precisions are better than the values reported until now in the literature, even with laser ablation coupled with multi-collector ICP-MS (MC-ICP-MS). For particles from other reference materials with low abundances of 235U, equal or close to the one of natural U, precisions for 235U/238U ratio measurements (4–5%) were not as good as the ones reported for MC-ICP-MS, but better than the ones obtained with single collector ICP-MS. Minor isotope ratios (234U/238U and 236U/238U) were also successfully measured, although with limited precision and accuracy when the abundances of the minor isotopes are very low, in the 10−5 range. This work shows that laser ablation coupled to ICP-TOF-MS has a great potential for ultra-precise isotope ratio measurements provided that the ablated area contains enough analyte and that abundances between isotopes are of the same order of magnitude.


  • Determination of the isotopic composition of micrometric uranium particles by UV femtosecond laser ablation coupled with sector-field single-collector ICP-MS

    by A. Donard, F. Pointurier, A.-C. Pottin, A. Hubert, C. Pécheyran

    In this article, performance of the coupling of a UV-fs-LA system with a high sensitivity ICP-MS for isotope analysis of individual micrometric uranium particles, including minor isotopes 234 U and 236 U, is discussed.


  • Round-robin 230Th–234U age dating of bulk uranium for nuclear forensics

    by Amy M. Gaffney, Amélie Hubert, William S. Kinman, Masaaki Magara, Ayako Okubo, Fabien Pointurier, Kerri C. Schorzman, Robert E. Steiner, Ross W. Williams


  • Use of micro‐Raman spectrometry coupled with scanning electron microscopy to determine the chemical form of uranium compounds in micrometer‐size particles

    by F. Pointurier, O. Marie

    In the frame of nuclear safeguards, knowledge of the chemical form (stoichiometry) of the uranium compounds present in the micrometric particulate material sampled by wiping surfaces in an inspected nuclear facility may point out the industrial process implemented in the installation. Micro‐Raman spectroscopy (MRS) coupled with scanning electron microscopy (SEM) has been used for the first time to analyze micrometer‐size particles of various uranium oxides [UO2, U3O8, UO3, and UO4 · 4(H2O)] deposited on carbon disks. Uranium particles are detected by means of SEM, and Raman analysis is then directly carried out inside the SEM measurement chamber without moving the carbon disk from SEM to MRS. When particles are deposited on appropriate carbon disks (sticky carbon tapes), despite a loss of signal‐to‐noise ratio of about an order of magnitude with regard to the stand‐alone MRS, all uranium oxides are successfully identified in particles by in‐SEM Raman analysis, obtaining similar characteristic bands as the ones obtained with the stand‐alone MRS. Moreover, with the SEM–MRS coupling, particles as small as 1 µm can be analyzed, whereas, without the SEM–MRS coupling, only particles larger than ~5 µm are efficiently analyzed, after localization inside the SEM, transfer of the sample holder into the MRS, and relocation of the particles inside the MRS. Copyright © 2013 John Wiley & Sons, Ltd.