HYHaoxin Yang

Haoxin Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haoxin Yang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Layout and Testing Considerations for Developing Discrete Silicon-Carbide Three-Level T-Type Phase-Leg

    by Jingjie Xu, Li Zhang, Jian Yang, Youjun Yue, Tianxiang Yin, Haoxin Yang, Lei Lin

    The SiC MOSFETs exhibit superior fast switching performance, benefitting the T-type three-level (T-3L) converter with enhanced conversion efficiency, power density, and control bandwidth. The newly emerging commercial SiC T-3L power modules are expensive with dissatisfactory availability. To provide a cost-effective alternative, therefore, this article investigates the layout and testing considerations for developing SiC T-3L phase-legs by using discrete SiC devices. The coupling effects within the current commutation power loops are studied, identifying the major factors that contribute to the power loop inductance. Taking advantage of the partial magnetic field self-cancellation technique, two types of layouts, namely, windmill-type layout and block-type layout, are proposed for developing the SiC T-3L phase-leg with minimized power loop inductance. To accurately evaluate the switching performances, including switching stresses and switching losses, specific considerations are further proposed for testing the SiC T-3L phase-leg. Finally, the experimental results are given to validate the feasibility of the proposed work.

  • Power System Inertia Enhancement Based on LVDC Microgrids

    by Haoxin Yang, Fei Deng, Lei Zhang, Ziheng Xiao, Zhigang Yao, Yi Tang

    There is a critical need to increase power system inertia during the grid transformation. However, in a low-voltage dc (LVDC) microgrid, many potential inertia contributors, such as energy storage systems, are linked to the local dc bus and managed by their individual distributed controllers. This configuration results in a lack of access to grid frequency information, limiting their ability to emulate inertia. To address this challenge without relying on real-time communications, this article proposes a power system inertia enhancement scheme based on LVDC microgrids. This scheme ensures that all potential units within the LVDC microgrids can be mobilized and independently configured to enhance the power system inertia. Furthermore, it also accounts for and compensates for various disturbances encountered within LVDC microgrids, like load switching. Experimental verifications are provided, demonstrating the effectiveness of the proposed method.


  • A Trapezoidal Current Mode to Reduce Peak Current in Near-CRM for Three-Level DC–DC Converter

    by Zhigang Yao, Xinyu He, Haogang Lan, Haoxin Yang, Ziheng Xiao, Fei Deng, Caisheng Wang, Yi Tang

    Triangular current mode (TCM) and near-critical conduction mode (near-CRM) are popularly used in dc–dc converters to achieve zero-voltage switching (ZVS). However, they encounter a huge peak current problem, more than twice the average current. To solve this problem, this article proposes a novel trapezoidal current mode (TZCM) for three-level dc–dc converters, aiming to reduce the inductor peak current and realize ZVS simultaneously. A trapezoidal modulation with 2-1-0 level sequences and duty cycle swapping is developed to generate the trapezoidal inductor current. To take advantage of the TZCM, a variable switching frequency control is proposed to realize ZVS for all switches in the full operating range. Compared with TCM, the proposed TZCM and its modulation not only reduce the conduction and turn- off losses of the power switches by lowering the peak and rms currents but also realize ZVS at D = 0.5, where ZVS cannot be realized in the traditional modulation because the inductor current ripple is equal to zero. The proposed TZCM and variable switching frequency control are validated using a 2-kW prototype with 99.06% efficiency.


  • A Noninvasive Grid Impedance Estimation Method With Phase-Lock Loops

    by Haoxin Yang, Yi Tang

    For grid-following inverters (GFIs), an accurate grid impedance estimation (GIE) enables many beneficial applications. Conventional active GIE methods, such as the PQ variation method, intentionally introduce power disturbances around the system's steady-state operating point. However, it might bring undesired reactive power into the grid and its accuracy can be influenced by phase lock loop (PLL) phase angle variations. To address these challenges, this letter proposes a noninvasive GIE method, which utilizes PLL's inherent operating characteristics. It only requires a single steady-state operating point transition that naturally occurs during the system's normal operation, eliminating the need to inject deliberate PQ disturbances. Additionally, by considering PLL phase angle variations, this method also ensures accurate estimation results across diverse conditions. Experimental verifications are provided, which demonstrate the effectiveness and accuracy of the proposed method.


  • Research on Transient Voltage Disturbance Monitoring Techniques in Power Systems

    by Dandan Zhao, Lin He, Haoxin Yang, Xingxing Zhou, Ruoyu Wang

    To solve the issue of accurate monitoring of transient voltage disturbances in power systems, which conventional Capacitor Voltage Transformers (CVTs) are unable to handle, this paper presents a transient voltage disturbance monitoring device designed for 500kV systems. This device is based on a Capacitor Voltage Transformer including the addition of a large capacitor C3 connected in series at the low-voltage end of the existing CVT. The performance of this device was evaluated by experiment, and the results indicate that the transient characteristics and waveform tracking capabilities of the device meet the technical specifications. Currently, the device is operated effectively in the field.

  • Decoupled Modulation With Common-Mode Load-Voltage Control for Three-Phase Four-Leg Three-Level Inverter

    by Li Zhang, Haoxin Yang, Yi Tang, Josep Pou, Leon M. Tolbert

    Three-phase four-leg four-wire (3P4L4W) three -level (3L) inverters have the ability to supply both balanced and unbalanced loads. This letter establishes common-mode (CM) and differential-mode (DM) circuit models for the 3P4L4W 3L inverter. It is revealed that the 3L phase-leg CM voltage is determined by the voltage balancing control (VBC) for the split dc bus voltages, that the DM load voltages are subject to the DM voltage control for the 3L phase leg, and that the CM load voltage is subject to the control for the fourth phase leg. On this basis, a decoupled modulation is proposed where the 3L phase legs are modulated to attain VBC and closed-loop DM load-voltage control, whereas the fourth phase leg is independently modulated to realize the closed-loop CM load-voltage control. The proposed work has been experimentally verified, showing that the 3P4L4W 3L inverter with this decoupled modulation scheme can provide well-balanced ac load voltages and low total harmonic distortion for any type of ac loads: balanced, unbalanced, linear, and nonlinear.


  • Exploration of Time-Delay Effect on the Stability of Grid-Connected Power Converters with Virtual Inertia

    by Haoxin Yang, Jingyang Fang, Yi Tang

    The lack of inertia contributions from renewable generators, which are essentially power electronic converters in replacement of synchronous generators, may greatly degrade the frequency regulation performance. As a solution, distributed virtual inertia provided by grid-connected power converters has been introduced as an effective approach to improve power system inertia. However, time-delays, which can be introduced by signal measurement, converter control, and communication, are ignored in the existing virtual inertia control implementations. To fill this research gap, this paper presents a detailed analysis of the effect of time-delays on virtual inertia control. It is revealed that instability will happen when the virtual inertia is greater than the existing power system inertia regardless of time-delays. In other cases, the system stability depends on time-delays, together with other design parameters. For verification, the experimental results are presented, which are consistent with the theoretical analysis.