Eline A. Feitsma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eline A. Feitsma has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Schelto Kruijff
Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
3 shared publications - Gooitzen Michell van Dam
Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
2 shared publications - Hugo Marijn Schouw
Department of Surgery, University Medical Centre Groningen, 9713 GZ Groningen, The Netherlands
2 shared publications - Milou Esmée Noltes
Department of Surgery, University Medical Centre Groningen, 9713 GZ Groningen, The Netherlands
2 shared publications - Wendy Kelder
Department of Surgery, Academic Breast Centre Groningen, Martini Hospital , Groningen
2 shared publications - Wido Heeman
Department of Surgery, University Medical Centre Groningen, Groningen, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 18 June 2026
- Published by Elsevier in EANM Innovation
- Vol. 4
Detection of lymph node metastases of well-differentiated thyroid cancer using fluorescence-guided surgery with bevacizumab-IRDye800CW
- 18 June 2026
- Published by Elsevier in EANM Innovation
- Vol. 4
Open AccessDetection of lymph node metastases of well-differentiated thyroid cancer using fluorescence-guided surgery with bevacizumab-IRDye800CW
- Open Access
Standardized and Quantitative ICG Perfusion Assessment: Feasibility and Reproducibility in a Multicentre Setting
Indocyanine green near-infrared fluorescence (ICG-NIRF) imaging is widely used to assess tissue perfusion, yet its subjective interpretation limits correlation with postoperative parathyroid function. To address this, the Workflow model for ICG-angiography integrating Standardization and Quantification (WISQ) was developed. This exploratory prospective multicenter study evaluated the reproducibility of WISQ in adults undergoing total thyroidectomy at two Dutch university centres. Patients with contraindications to ICG or prior neck surgery were excluded. Intraoperative imaging used standardized camera settings with blood volume-adjusted ICG dosing, and perfusion curves were analyzed using predefined regions of interest. Eighty patients were included. Significant inter-centre variability was observed in maximum fluorescence intensity, inflow slope, and outflow slope (n = 30). At the lead centre, outflow was the most promising predictor of postoperative hypoparathyroidism (HPT) (median −0.33 [IQR −0.49–−0.15] a.f.u./s for HPT vs. −0.68 [−0.91–−0.41], n = 17, p = 0.08), although no parameter significantly predicted HPT. Repeated ICG injections consistently produced lower maximal intensities irrespective of injection rate, and reproducible curves were achieved only when ICG was freshly dissolved at 0.5 mg/mL instead of 2.5 mg/mL. These findings indicate that ICG concentration and injection technique influence perfusion kinetics and underscore the need to update WISQ with standardized injection dilution to improve its clinical utility.
Open AccessStandardized and Quantitative ICG Perfusion Assessment: Feasibility and Reproducibility in a Multicentre Setting
Indocyanine green near-infrared fluorescence (ICG-NIRF) imaging is widely used to assess tissue perfusion, yet its subjective interpretation limits correlation with postoperative parathyroid function. To address this, the Workflow model for ICG-angiography integrating Standardization and Quantification (WISQ) was developed. This exploratory prospective multicenter study evaluated the reproducibility of WISQ in adults undergoing total thyroidectomy at two Dutch university centres. Patients with contraindications to ICG or prior neck surgery were excluded. Intraoperative imaging used standardized camera settings with blood volume-adjusted ICG dosing, and perfusion curves were analyzed using predefined regions of interest. Eighty patients were included. Significant inter-centre variability was observed in maximum fluorescence intensity, inflow slope, and outflow slope (n = 30). At the lead centre, outflow was the most promising predictor of postoperative hypoparathyroidism (HPT) (median −0.33 [IQR −0.49–−0.15] a.f.u./s for HPT vs. −0.68 [−0.91–−0.41], n = 17, p = 0.08), although no parameter significantly predicted HPT. Repeated ICG injections consistently produced lower maximal intensities irrespective of injection rate, and reproducible curves were achieved only when ICG was freshly dissolved at 0.5 mg/mL instead of 2.5 mg/mL. These findings indicate that ICG concentration and injection technique influence perfusion kinetics and underscore the need to update WISQ with standardized injection dilution to improve its clinical utility.
- Open Access
Heterogeneity in Utilization of Optical Imaging Guided Surgery for Identifying or Preserving the Parathyroid Glands—A Meta-Narrative Review
Background: Postoperative hypoparathyroidism is the most common complication after total thyroidectomy. Over the past years, optical imaging techniques, such as parathyroid autofluorescence, indocyanine green (ICG) angiography, and laser speckle contrast imaging (LSCI) have been employed to save parathyroid glands during thyroid surgery. This study provides an overview of the utilized methods of the optical imaging techniques during total thyroidectomy for parathyroid gland identification and preservation. Methods: PUBMED, EMBASE and Web of Science were searched for studies written in the English language utilizing parathyroid autofluorescence, ICG-angiography, or LSCI during total thyroidectomy to support parathyroid gland identification or preservation. Case reports, reviews, meta-analyses, animal studies, and post-mortem studies were excluded after the title and abstract screening. The data of the studies were analyzed qualitatively, with a focus on the methodologies employed. Results: In total, 59 articles were included with a total of 6190 patients. Overall, 38 studies reported using parathyroid autofluorescence, 24 using ICG-angiography, and 2 using LSCI. The heterogeneity between the utilized methodology in the studies was large, and in particular, regarding study protocols, imaging techniques, and the standardization of the imaging protocol. Conclusion: The diverse application of optical imaging techniques and a lack of standardization and quantification leads to heterogeneous conclusions regarding their clinical value. Worldwide consensus on imaging protocols is needed to establish the clinical utility of these techniques for parathyroid gland identification and preservation.
Open AccessHeterogeneity in Utilization of Optical Imaging Guided Surgery for Identifying or Preserving the Parathyroid Glands—A Meta-Narrative Review
Background: Postoperative hypoparathyroidism is the most common complication after total thyroidectomy. Over the past years, optical imaging techniques, such as parathyroid autofluorescence, indocyanine green (ICG) angiography, and laser speckle contrast imaging (LSCI) have been employed to save parathyroid glands during thyroid surgery. This study provides an overview of the utilized methods of the optical imaging techniques during total thyroidectomy for parathyroid gland identification and preservation. Methods: PUBMED, EMBASE and Web of Science were searched for studies written in the English language utilizing parathyroid autofluorescence, ICG-angiography, or LSCI during total thyroidectomy to support parathyroid gland identification or preservation. Case reports, reviews, meta-analyses, animal studies, and post-mortem studies were excluded after the title and abstract screening. The data of the studies were analyzed qualitatively, with a focus on the methodologies employed. Results: In total, 59 articles were included with a total of 6190 patients. Overall, 38 studies reported using parathyroid autofluorescence, 24 using ICG-angiography, and 2 using LSCI. The heterogeneity between the utilized methodology in the studies was large, and in particular, regarding study protocols, imaging techniques, and the standardization of the imaging protocol. Conclusion: The diverse application of optical imaging techniques and a lack of standardization and quantification leads to heterogeneous conclusions regarding their clinical value. Worldwide consensus on imaging protocols is needed to establish the clinical utility of these techniques for parathyroid gland identification and preservation.