LJLing Jiang

Ling Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ling Jiang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Ligang Cui

    Peking University Third Hospital, Beijing, China

    2 shared publications
  • Gui-Juan Bi

    Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, People’s Republic of China

    1 shared publication
  • Heng Xue

    Department of Ultrasound, Peking University Third Hospital, Beijing 100191, China

    1 shared publication
  • Hua Zhang

    Clinical Epidemiology Research Center, Peking University Third Hospital, Beijing 100191, China

    1 shared publication
  • Jian-Quan Wang

    Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, People’s Republic of China

    1 shared publication
  • Jie Jiang

    Department of Ultrasound, Peking University Third Hospital, Beijing, China

    1 shared publication

Latest Publications

  • Open Access

    The Impact of Interscalene Brachial Plexus Block with Different Concentrations of Ropivacaine on Diaphragmatic Paralysis: A Randomized Controlled Study

    by Ying Deng, Liwei Wang, Hua Zhang, Zhichao Xu, Ling Jiang, Yang Zhou

    Background: This study aims to evaluate the degree of diaphragmatic paralysis by assessing diaphragmatic excursion and pulmonary function following an ultrasound-guided interscalene brachial plexus block with two different concentrations of ropivacaine (0.2% and 0.5%). Methods: Forty patients undergoing shoulder arthroscopic surgery were randomly assigned to receive ultrasound-guided interscalene brachial plexus block with 20 mL of either 0.2% or 0.5% ropivacaine. Diaphragmatic excursion (DE) and diaphragm thickening fraction (TF) were measured using M-mode ultrasound before and 30 minutes after the block. Pulmonary function was assessed using a portable spirometer. Additional outcomes included pain scores and the occurrence of adverse effects. Results: DE was significantly reduced 30 minutes after block in the 0.5% group compared to the 0.2% group (p< 0.01), as well as the TF (p< 0.01). Forced vital capacity (FVC) was also significantly reduced in the 0.5% group 30 minutes after block in the preparation room compared to the 0.2% group (p< 0.001). Both 0.2% and 0.5% ropivacaine had similar effects in improving postoperative pain. There were no serious block-related complications in either group. Conclusion: 0.2% ropivacaine may impair pulmonary function less than 0.5% ropivacaine. The clinical significance of these differences requires further investigation.


  • Open Access

    A comparison between ultrasound-guided AIIS injection and radiography in the diagnosis of subspine impingement in patients with FAI

    by Zi-Yi He, Zi-Ming Liu, Gui-Juan Bi, Xiao-Le Zhang, Jian-Quan Wang, Ling Jiang, Xiao-Dong Ju

    Background: Subspine impingement (SSI) does not have effective diagnostic criteria, especially in patients who also have femoroacetabular impingement (FAI). The classification of anterior inferior iliac spine (AIIS) morphology via three-dimensional CT is controversial. Purpose: To propose a method for ultrasound-guided AIIS injection as a way to diagnose SSI and evaluate the accuracy of radiography methods, including 3-D CT and MRI, as well as intraoperative findings. Methods: Patients diagnosed with FAI between September 2020 and December 2021 were evaluated in this prospective study. Those who met the criteria were included in the ultrasound-guided AIIS injection test. Whether the pain was relieved after injection was recorded in the radiology report. Patients who experienced significant relief of the anterior groin pain (more than 50%) after the AIIS injection were considered positive responders. Among these patients, radiography materials, including AIIS morphology as measured by 3-D CT as well as superior capsular oedema on MRI, were compared. The presence of congestion or bruising on the capsule side of the labrum corresponding to the AIIS during hip arthroscopy was recorded. Results: A total of 73 patients with FAI underwent the ultrasound-guided AIIS injection test. Prevalence rates of 13.70% (10/73), 58.90% (43/73), 23.29% (17/73) and 4.11% (3/73) were recorded for Type I, Type IIA, Type IIB and Type III AIISs, respectively. Thirty-six patients had positive responses to injection, and 37 patients had negative responses to injection. None of the patients with Type I, 23 (53.49%) patients with Type IIA, 11 (64.71%) patients with Type IIB and 2 (66.7%) patients with Type III AIISs had positive responses to the injection. A total of 57.14% of patients with Type II or Type III AIIS had positive responses to the injection. The proportions of patients with superior capsular oedema on MRI in the Type I, Type IIA, Type IIB, and Type III AIIS groups was 0, 30.23, 29.41 and 0%, respectively. Among non-Type I AIIS patients, those who reported positive responses to the injection had a higher incidence of superior capsular oedema (38.89% vs. 14.81%, P = 0.036), but they had no significant differences in the proportion of congestion or bruising of the labrum (47.22% vs. 37.04%, P = 0.419). The results showed that no pairs of methods—ultrasound-guided injection, MRI, and intraoperative findings—achieved good consistency (κ = 0.222, κ = 0.098 and κ = − 0.116). Conclusions: Radiographic methods including 3-D CT and MRI as well as the intraoperative findings of the labrum cannot be considered an accurate and reliable basis for the diagnosis and treatment of SSI in FAI patients. It is suggested that ultrasound-guided AIIS injections be combined with radiography to better diagnose SSI. Level of Evidence: IV, case series.


  • Open Access

    Shear Wave Dispersion Slope Measured with Shear Wave Dispersion Imaging Is Associated with Variceal Hemorrhage in Cirrhotic Patients

    by Xiaohui Sun, Li Zhang, Ling Jiang, Ligang Cui, Xiaoguang Li

    Background and Objectives: Portal hypertension (PH), as the main consequence of cirrhosis, leads to the development of gastroesophageal varices (GEVs). Variceal hemorrhage (VH) caused by the rupture of GEVs is a life-threatening emergency. Thus, the prediction of VH risk is considerably important. Our pilot study aimed to identify the risk factors of variceal hemorrhage (VH) in cirrhosis. Materials and Methods: Cirrhotic patients were prospectively included and divided into two groups according to the presence or absence of VH. Conventional ultrasound and shear wave dispersion (SWD) imaging were conducted to detect the portal vein diameter, spleen diameter, ascites, liver stiffness (LS) and shear wave dispersion slope (SWDS). The laboratory tests were recorded, including platelets (PLT), alanine transaminase (ALT), aspartate aminotransferase (AST), total bilirubin (TBIL) and albumin (ALB). The risk factors of VH were screened using univariate analyses and identified using multivariate logistic regression. The ROC curves were used to assess diagnostic accuracy. Comparisons between AUCs were performed using the Delong method. Results: Sixty-five patients with 22 VHs were finally included. The SWDS, spleen diameter and ascites were identified as independent risk factors for VH. The SWDS showed good performance for diagnosing VH (AUC = 0.768, 95% CI: 0.647–0.864), and sensitively identified 95.5% (95% CI: 77.2%–99.9%) of patients with VH. Including the three risk factors in multivariate logistic regression, we obtained a formula for diagnosing VH: −20.749 + 0.804 × SWDS + 0.449 × spleen diameter + 1.803 × ascites (no ascites = 0, ascites = 1). Comparison of AUCs revealed that the formula (AUC = 0.900, 95% CI: 0.800–0.961) performed better than LS, SWDS, and spleen diameter in diagnosing VH (p < 0.001; p < 0.05; p < 0.05). Conclusions: SWDS is a sensitive parameter for assessing the risk of VH. Combining the SWDS, spleen diameter and ascites resulted in good diagnostic accuracy.


  • Open Access

    Anchoring Apparatus of Long Head of the Biceps Tendon: Ultrasonographic Anatomy and Pathologic Conditions

    by Heng Xue, Stephen Bird, Ling Jiang, Jie Jiang, Ligang Cui

    The long head of the biceps tendon (LHBT) has been recognized as an important generator of anterior shoulder pain, causing a significant reduction in the shoulder flexion range. Various tendinous and ligamentous structures form the anchoring apparatus of the LHBT along its course to maintain its appropriate location during shoulder movements, including the coracohumeral ligament (CHL), superior glenohumeral ligament (SGHL), subscapularis (SSC) tendon and supraspinatus (SSP) tendon as well as the less recognized tendons of pectoralis major (PM), latissimus dorsi (LD) and teres major (TM). Lesions of this stabilizing apparatus may lead to an instability of the LHBT, resulting in pain at the anterior shoulder. Ultrasonography (US) has been increasingly used in the assessment of shoulder injuries, including the anchoring apparatus of the LHBT. An accurate diagnosis of these injuries is often challenging, given the complex anatomy and wide spectrum of pathologies. In this review article, US anatomy and common pathologic conditions that affect the anchoring apparatus of the LHBT are discussed, including biceps pulley lesions, adhesive capsulitis, chronic pathology of SSC and SSP tendons, tears in the PM tendon and injuries to the LD and TM. Knowledge of a normal anatomy, an appropriate scanning technique and US findings of common pathologic conditions are the keys to accurate diagnoses.