HongMei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
HongMei Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
JingJing Tian
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou New District, Jiangsu Province 215163, China
1 shared publicationM. Wang
Suzhou Red Cross Blood Center, Suzhou, China
1 shared publication- Qing-Lin Meng
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
1 shared publication S. Ding
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
1 shared publicationS. Duan
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
1 shared publicationS. Wei
CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
1 shared publication
Latest Publications
- 9 September 2019
- Published by Wiley in Transfusion Medicine
- Vol. 29 (5) , 344-350
A new reliable test for crossmatching: microplate hydrogel immunoassay technology
SUMMARY: Objectives: To provide a novel assay to detect incomplete antibodies in the crossmatching test.Background: There is a requirement in China that both major and minor crossmatch tests are required. Among all methods of crossmatching, the tube anti‐human globulin test requires tedious washing steps and is time‐consuming, whereas the microcolumn gel immunoassay anti‐human globulin test is susceptible to sample quality.Methods: The process of the microplate hydrogel immunoassay anti‐human globulin test involves the use of our patented hydrogel chromatography medium and U‐bottom microplates pre‐coated with goat anti‐human globulin (AHG). A mixture of red blood cells (RBCs) and serum is centrifuged through the hydrogel under precise conditions. In incompatible reactions, the sensitised RBCs are captured by the pre‐coated AHG and form a layer over the bottom of the well, whereas in compatible reactions, the unbound RBCs form a button at the bottom of the well. The sensitivity of this new approach and the performance when testing old specimens were evaluated.Results: This approach was more convenient and slightly more sensitive than the tube anti‐human globulin test and was superior to the microcolumn gel immunoassay when testing old specimens.Conclusion: In general, this assay is suitable for the routine clinical use of crossmatching to detect incomplete antibodies.
- 9 September 2019
- Published by Wiley in Transfusion Medicine
- Vol. 29 (5) , 344-350
A new reliable test for crossmatching: microplate hydrogel immunoassay technology
SUMMARY: Objectives: To provide a novel assay to detect incomplete antibodies in the crossmatching test.Background: There is a requirement in China that both major and minor crossmatch tests are required. Among all methods of crossmatching, the tube anti‐human globulin test requires tedious washing steps and is time‐consuming, whereas the microcolumn gel immunoassay anti‐human globulin test is susceptible to sample quality.Methods: The process of the microplate hydrogel immunoassay anti‐human globulin test involves the use of our patented hydrogel chromatography medium and U‐bottom microplates pre‐coated with goat anti‐human globulin (AHG). A mixture of red blood cells (RBCs) and serum is centrifuged through the hydrogel under precise conditions. In incompatible reactions, the sensitised RBCs are captured by the pre‐coated AHG and form a layer over the bottom of the well, whereas in compatible reactions, the unbound RBCs form a button at the bottom of the well. The sensitivity of this new approach and the performance when testing old specimens were evaluated.Results: This approach was more convenient and slightly more sensitive than the tube anti‐human globulin test and was superior to the microcolumn gel immunoassay when testing old specimens.Conclusion: In general, this assay is suitable for the routine clinical use of crossmatching to detect incomplete antibodies.
- 16 June 2015
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 53 (3) , 337-341
A new approach to detection of incomplete antibodies using hydrogel chromatography medium
- 16 June 2015
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 53 (3) , 337-341
A new approach to detection of incomplete antibodies using hydrogel chromatography medium