Hyun Woo Sung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyun Woo Sung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Soojung Claire Hur
Department of Mechanical Engineering, Johns Hopkins University, 3400 N Charles Street, Baltimore, MD 21218, USA
3 shared publications - Benjamin Treutler
Department of Biomedical Engineering, Johns Hopkins University, 3400 N Charles Street, Baltimore, MD 21218, USA
1 shared publication Chris H. Chu
Affiliation Department of Internal Medicine, Virginia Mason Medical Center, Seattle, Washington, United States of America
1 shared publication- Corinna Torabi
Department of Mechanical Engineering, Johns Hopkins University, 3400 N Charles Street, Baltimore, MD 21218, USA
1 shared publication - Dohyun Kim
Department of Mechanical Engineering, Myongji University, Yongin, Republic of Korea
1 shared publication - Harrison Khoo
Department of Mechanical Engineering, Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, United States
1 shared publication
Latest Publications
- Open Access
- 15 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (3) , 359
Integrated Size-Selective Cell Purification and Electroporation for Genetic Manipulation of Primary Cells
Biologically relevant primary cell samples are inherently heterogeneous and often require selective enrichment prior to genetic manipulation. We previously demonstrated a vortex-assisted microfluidic platform that integrates size-selective cell trapping with electroporation; however, its limited processing capacity constrained applications requiring larger sample volumes. Here, we present a scaled version of this integrated system achieved through electrode array redesign and electrical optimization. The updated architecture increases processing capacity while preserving size-selective trapping behavior, electric field uniformity, and device stability. Systematic optimization of electrical and buffer conditions enables efficient delivery of plasmid DNA and in vitro-transcribed mRNA into primary human cells, with performance approaching benchmark chemical transfection methods. By scaling an integrated trapping–electroporation workflow without compromising delivery performance, this platform advances microfluidic cell engineering toward practical processing of heterogeneous primary cell samples.
- 15 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (3) , 359
Open AccessIntegrated Size-Selective Cell Purification and Electroporation for Genetic Manipulation of Primary Cells
Biologically relevant primary cell samples are inherently heterogeneous and often require selective enrichment prior to genetic manipulation. We previously demonstrated a vortex-assisted microfluidic platform that integrates size-selective cell trapping with electroporation; however, its limited processing capacity constrained applications requiring larger sample volumes. Here, we present a scaled version of this integrated system achieved through electrode array redesign and electrical optimization. The updated architecture increases processing capacity while preserving size-selective trapping behavior, electric field uniformity, and device stability. Systematic optimization of electrical and buffer conditions enables efficient delivery of plasmid DNA and in vitro-transcribed mRNA into primary human cells, with performance approaching benchmark chemical transfection methods. By scaling an integrated trapping–electroporation workflow without compromising delivery performance, this platform advances microfluidic cell engineering toward practical processing of heterogeneous primary cell samples.
- Open Access
- 8 March 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (3) , e0264907
Sensitizing drug-resistant cancer cells from blood using microfluidic electroporator
Direct assessment of patient samples holds unprecedented potential in the treatment of cancer. Circulating tumor cells (CTCs) in liquid biopsies are a rapidly evolving source of primary cells in the clinic and are ideal candidates for functional assays to uncover real-time tumor information in real-time. However, a lack of routines allowing direct and active interrogation of CTCs directly from liquid biopsy samples represents a bottleneck for the translational use of liquid biopsies in clinical settings. To address this, we present a workflow for using a microfluidic vortex-assisted electroporation system designed for the functional assessment of CTCs purified from blood. Validation of this approach was assessed through drug response assays on wild-type (HCC827 wt) and gefitinib-resistant (HCC827 GR6) non-small cell lung cancer (NSCLC) cells. HCC827 cells trapped within microscale vortices were electroporated to sequentially deliver drug agents into the cytosol. Electroporation conditions facilitating multi-agent delivery were characterized for both cell lines using an automatic single-cell image fluorescence intensity algorithm. HCC827 GR6 cells spiked into the blood to emulate drug-resistant CTCs were able to be collected with high purity, demonstrating the ability of the device to minimize background cell impact for downstream sensitive cell assays. Using our proposed workflow, drug agent combinations to restore gefitinib sensitivity reflected the anticipated cytotoxic response. Taken together, these results represent a microfluidics multi-drug screening panel workflow that can enable functional interrogation of patient CTCs in situ, thereby accelerating the clinical standardization of liquid biopsies.
- 8 March 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (3) , e0264907
Open AccessSensitizing drug-resistant cancer cells from blood using microfluidic electroporator
Direct assessment of patient samples holds unprecedented potential in the treatment of cancer. Circulating tumor cells (CTCs) in liquid biopsies are a rapidly evolving source of primary cells in the clinic and are ideal candidates for functional assays to uncover real-time tumor information in real-time. However, a lack of routines allowing direct and active interrogation of CTCs directly from liquid biopsy samples represents a bottleneck for the translational use of liquid biopsies in clinical settings. To address this, we present a workflow for using a microfluidic vortex-assisted electroporation system designed for the functional assessment of CTCs purified from blood. Validation of this approach was assessed through drug response assays on wild-type (HCC827 wt) and gefitinib-resistant (HCC827 GR6) non-small cell lung cancer (NSCLC) cells. HCC827 cells trapped within microscale vortices were electroporated to sequentially deliver drug agents into the cytosol. Electroporation conditions facilitating multi-agent delivery were characterized for both cell lines using an automatic single-cell image fluorescence intensity algorithm. HCC827 GR6 cells spiked into the blood to emulate drug-resistant CTCs were able to be collected with high purity, demonstrating the ability of the device to minimize background cell impact for downstream sensitive cell assays. Using our proposed workflow, drug agent combinations to restore gefitinib sensitivity reflected the anticipated cytotoxic response. Taken together, these results represent a microfluidics multi-drug screening panel workflow that can enable functional interrogation of patient CTCs in situ, thereby accelerating the clinical standardization of liquid biopsies.
- Open Access
- 3 March 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 257
Inertial Microfluidics Enabling Clinical Research
Fast and accurate interrogation of complex samples containing diseased cells or pathogens is important to make informed decisions on clinical and public health issues. Inertial microfluidics has been increasingly employed for such investigations to isolate target bioparticles from liquid samples with size and/or deformability-based manipulation. This phenomenon is especially useful for the clinic, owing to its rapid, label-free nature of target enrichment that enables further downstream assays. Inertial microfluidics leverages the principle of inertial focusing, which relies on the balance of inertial and viscous forces on particles to align them into size-dependent laminar streamlines. Several distinct microfluidic channel geometries (e.g., straight, curved, spiral, contraction-expansion array) have been optimized to achieve inertial focusing for a variety of purposes, including particle purification and enrichment, solution exchange, and particle alignment for on-chip assays. In this review, we will discuss how inertial microfluidics technology has contributed to improving accuracy of various assays to provide clinically relevant information. This comprehensive review expands upon studies examining both endogenous and exogenous targets from real-world samples, highlights notable hybrid devices with dual functions, and comments on the evolving outlook of the field.
- 3 March 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 257
Open AccessInertial Microfluidics Enabling Clinical Research
Fast and accurate interrogation of complex samples containing diseased cells or pathogens is important to make informed decisions on clinical and public health issues. Inertial microfluidics has been increasingly employed for such investigations to isolate target bioparticles from liquid samples with size and/or deformability-based manipulation. This phenomenon is especially useful for the clinic, owing to its rapid, label-free nature of target enrichment that enables further downstream assays. Inertial microfluidics leverages the principle of inertial focusing, which relies on the balance of inertial and viscous forces on particles to align them into size-dependent laminar streamlines. Several distinct microfluidic channel geometries (e.g., straight, curved, spiral, contraction-expansion array) have been optimized to achieve inertial focusing for a variety of purposes, including particle purification and enrichment, solution exchange, and particle alignment for on-chip assays. In this review, we will discuss how inertial microfluidics technology has contributed to improving accuracy of various assays to provide clinically relevant information. This comprehensive review expands upon studies examining both endogenous and exogenous targets from real-world samples, highlights notable hybrid devices with dual functions, and comments on the evolving outlook of the field.