Nina Popov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nina Popov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ana Peršić
Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia
1 shared publication - Bratislav Antic
VINČA Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, P.O. Box 522 Belgrade, Serbia
1 shared publication - Dalibor Stanković
Faculty of Chemistry, University of Belgrade, Belgrade, Serbia
1 shared publication - Elza Štefanović
Faculty of Chemical Engineering and Technology, University of Zagreb, Zagreb, Croatia, EU
1 shared publication Emi Govorčin Bajsić
Faculty of Chemical Engineering and Technology, University of Zagreb, Zagreb, Croatia, EU
1 shared publication- Ferenc T. Pastor
Faculty of Chemistry, University of Belgrade, Studentski trg 12-16, 11000 Belgrade, Serbia
1 shared publication
Latest Publications
- Open Access
- 27 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 932
Electrochemical Determination of Morphine in Urine Samples by Tailoring FeWO4/CPE Sensor
Morphine (MORPH) is natural alkaloid and mainly used as a pain reliever. Its monitoring in human body fluids is crucial for modern medicine. In this paper, we have developed an electrochemical sensor for submicromolar detection of MORPH. The sensor is based on modified carbon paste electrode (CPE) by investigating the FexW1-xO4 ratio in iron tungstate (FeWO4), as well as the ratio of this material in CPE. For the first time, the effect of the iron–tungsten ratio in terms of achieving the best possible electrochemical characteristics for the detection of an important molecule for humans was examined. Morphological and electrochemical characteristics of materials were studied. The best results were obtained using Fe1W3 and 7.5% of modifier in CPE. For MORPH detection, square wave voltammetry (SWV) was optimized. Under the optimized conditions, Fe1W3@CPE resulted in limit of detection (LOD) of the method of 0.58 µM and limit of quantification (LOQ) of 1.94 µM. The linear operating range between 5 and 85 µM of MORPH in the Britton–Robinson buffer solution (BRBS) at pH 8 as supporting electrolyte was obtained. The Fe1W3@CPE sensor resulted in good selectivity and excellent repeatability with relative standard deviation (RSD) and was applied in real-world samples of human urine. Application for direct MORPH detection, without tedious sample pretreatment procedures, suggests that developed electrochemical sensor has appeared to be a suitable competitor for efficient, precise, and accurate monitoring of the MORPH in biological fluids.
- 27 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (11) , 932
Open AccessElectrochemical Determination of Morphine in Urine Samples by Tailoring FeWO4/CPE Sensor
Morphine (MORPH) is natural alkaloid and mainly used as a pain reliever. Its monitoring in human body fluids is crucial for modern medicine. In this paper, we have developed an electrochemical sensor for submicromolar detection of MORPH. The sensor is based on modified carbon paste electrode (CPE) by investigating the FexW1-xO4 ratio in iron tungstate (FeWO4), as well as the ratio of this material in CPE. For the first time, the effect of the iron–tungsten ratio in terms of achieving the best possible electrochemical characteristics for the detection of an important molecule for humans was examined. Morphological and electrochemical characteristics of materials were studied. The best results were obtained using Fe1W3 and 7.5% of modifier in CPE. For MORPH detection, square wave voltammetry (SWV) was optimized. Under the optimized conditions, Fe1W3@CPE resulted in limit of detection (LOD) of the method of 0.58 µM and limit of quantification (LOQ) of 1.94 µM. The linear operating range between 5 and 85 µM of MORPH in the Britton–Robinson buffer solution (BRBS) at pH 8 as supporting electrolyte was obtained. The Fe1W3@CPE sensor resulted in good selectivity and excellent repeatability with relative standard deviation (RSD) and was applied in real-world samples of human urine. Application for direct MORPH detection, without tedious sample pretreatment procedures, suggests that developed electrochemical sensor has appeared to be a suitable competitor for efficient, precise, and accurate monitoring of the MORPH in biological fluids.
- Open Access
- 1 January 2021
- Published by TANGER Ltd.
The influence of the size of hematite particles on the properties of polyethylene/hematite composites
- 1 January 2021
- Published by TANGER Ltd.
Open AccessThe influence of the size of hematite particles on the properties of polyethylene/hematite composites