Iacopo Rainaldi
Iacopo Rainaldi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Cappelli
Division of Occupational Medicine, Careggi University Hospital, 50134 Florence, Italy
2 shared publications - Giulia Pizzella
Eni Health, Safety, Environment & Quality EE, Via Ribotta 51, 00144 Rome, Italy
2 shared publications - Nicola Mucci
Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy
2 shared publications - Alessandro Bonari
General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
1 shared publication - Alfonso Pavone
Eni Health, Safety, Environment & Quality EE, Via Ribotta 51, 00144 Rome, Italy
1 shared publication - Antonio Marigliano
Department of Experimental and Clinical Medicine, University of Florence, Largo Brambilla 3, 50121 Florence, Italy
1 shared publication
Latest Publications
- Open Access
Regarding Bioanalysis Lasting a Few Minutes: Automated Cooling-SPME and Fast-GC for Urinary 2-Phenyl-2-Propanol Monitoring
An innovative SPME head space GC–MS method, in cooling mode, using a fully automated routine, was developed to detect 2-phenyl-2-propanol, a representative urinary metabolite of cumene. Following an acid hydrolysis and derivatization step with lowered quantities of reagents, acetic anhydride and pyridine, a 30 μm polydimethylsiloxane SPME fiber was used to sample derivatized 2-phenyl-2-propanol, such as benzenemethanol,α,α-dimethyl-acetate, from the headspace. Performances of the method, optimized through experimental design, provide an LOD of 0.034 mg/L and an LOQ 0.10 mg/L, with a short sampling time necessary per sample. The method, developed on standard solutions, will be applied to both occupationally exposed and non-exposed populations.
Open AccessRegarding Bioanalysis Lasting a Few Minutes: Automated Cooling-SPME and Fast-GC for Urinary 2-Phenyl-2-Propanol Monitoring
An innovative SPME head space GC–MS method, in cooling mode, using a fully automated routine, was developed to detect 2-phenyl-2-propanol, a representative urinary metabolite of cumene. Following an acid hydrolysis and derivatization step with lowered quantities of reagents, acetic anhydride and pyridine, a 30 μm polydimethylsiloxane SPME fiber was used to sample derivatized 2-phenyl-2-propanol, such as benzenemethanol,α,α-dimethyl-acetate, from the headspace. Performances of the method, optimized through experimental design, provide an LOD of 0.034 mg/L and an LOQ 0.10 mg/L, with a short sampling time necessary per sample. The method, developed on standard solutions, will be applied to both occupationally exposed and non-exposed populations.
- Open Access
- 10 March 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (3) , 450
Low-Dose Benzene Exposure Monitoring of Oil Refinery Workers: Inhalation and Biomarkers
Airborne benzene in workplaces has progressively decreased due to preventive actions and the redesigning of facility processes. Professionals who assess occupational exposure should select techniques to detect benzene levels comparable to ambient air exposure. Thus, sensitive biomarkers are needed to discriminate the effects of confounding factors, such as smoking or sorbic acid (SA). In order to identify sensitive biomarkers and to study their correlation with confounding factors, 23 oil refinery workers were enrolled in the study; their airborne benzene exposures and biomarkers were monitored. Urinary benzene (U-B), t,t-muconic acid (t,t-MA), and S-phenylmercapturic acid (SPMA) were quantified. Urinary cotinine (U-C) and t,t-sorbic acid (t,t-SA) were evaluated to flag smoking and SA intake, respectively. The benzene measured in personal inhalation sampling ranged from 0.6 to 83.5 (median 1.7) µg/m3. The concentration range of the biomarkers, U-B, t,t-MA, and SPMA, were 18–4893 ng/m3, p < 0.001) and between benzene and SPMA (g/L r = 0.812, p < 0.001), followed by benzene and t,t-MA (mg/L r = 0.465, p = 0.039). From our study, U-B and SPMA result to be the most reliable biomarkers to assess the internal number of low doses of benzene exposure, thanks to their specificity and sensitivity.
- 10 March 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (3) , 450
Open AccessLow-Dose Benzene Exposure Monitoring of Oil Refinery Workers: Inhalation and Biomarkers
Airborne benzene in workplaces has progressively decreased due to preventive actions and the redesigning of facility processes. Professionals who assess occupational exposure should select techniques to detect benzene levels comparable to ambient air exposure. Thus, sensitive biomarkers are needed to discriminate the effects of confounding factors, such as smoking or sorbic acid (SA). In order to identify sensitive biomarkers and to study their correlation with confounding factors, 23 oil refinery workers were enrolled in the study; their airborne benzene exposures and biomarkers were monitored. Urinary benzene (U-B), t,t-muconic acid (t,t-MA), and S-phenylmercapturic acid (SPMA) were quantified. Urinary cotinine (U-C) and t,t-sorbic acid (t,t-SA) were evaluated to flag smoking and SA intake, respectively. The benzene measured in personal inhalation sampling ranged from 0.6 to 83.5 (median 1.7) µg/m3. The concentration range of the biomarkers, U-B, t,t-MA, and SPMA, were 18–4893 ng/m3, p < 0.001) and between benzene and SPMA (g/L r = 0.812, p < 0.001), followed by benzene and t,t-MA (mg/L r = 0.465, p = 0.039). From our study, U-B and SPMA result to be the most reliable biomarkers to assess the internal number of low doses of benzene exposure, thanks to their specificity and sensitivity.