Ivan Poroskun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ivan Poroskun has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Christian Rothleitner
Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
3 shared publications A. Narymany Shandy
Interessengemeinschaft Automatisierungstechnik der Prozessindustrie). Mit Mitteilungen der GMA (VDI /VDE-Gesellschaft Mess-und Automatisierungstechnik). tm ist die Fachzeitschrift für anwendungsbezogene industrielle Messtechnik als eine der wesentlichen Komponenten für Automatisierung, Prozessüberwachung
1 shared publicationAchim Winterstein
WISSENSCHAFTLICHER BEIRAT
1 shared publication- Andreas Fischer
University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
1 shared publication Bayreuth Heizmann
JOuRnal cOORDinaTOR Ulrike Kitzing, De Gruyter, Genthiner Straße 13, 10785 Berlin, Germany
1 shared publicationBerlin Beyerer
VERLAG Walter de Gruyter GmbH, Berlin/Boston, Genthiner Straße 13, 10785 Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 5 September 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (5) , 055007
A method for evaluating the force factor in oscillating Kibble balances with application to the Planck-Balance
The Planck-Balance is a table-top version of a Kibble balance, developed in a collaboration between the PTB and TU Ilmenau. In contrast to most Kibble balances, where the motion range is of up to several centimeters in the velocity mode, in the Planck-Balance it is below 100 μm. For a reliable determination of the force factor, the voice coil is set into harmonic oscillation, resulting in an induced AC voltage. The amplitude of the first harmonic is then taken to determine the force factor. However, due to the non-linear magnetic field across the motion range, the first harmonic is subject to a bias, and higher harmonics are excited. Those higher harmonics contain the information about the relative magnitude of the bias in the first harmonic, and can be used for a correction. In this paper we present an analytical model and show its application with real measurements. The estimated relative bias amounts to − 6.3 ⋅ 10 − 6 , with a residual relative uncertainty of 6.3 ⋅ 10 − 7 , for an oscillation amplitude of 20 μm. This method is especially of importance for Kibble balances with short motion range and working with harmonic oscillation. After such a correction is applied, a table-top version of a Kibble balance can be used as a conventional balance calibrated by means of E2 mass standards in the whole E2 class mass range.
- 5 September 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (5) , 055007
Open AccessA method for evaluating the force factor in oscillating Kibble balances with application to the Planck-Balance
The Planck-Balance is a table-top version of a Kibble balance, developed in a collaboration between the PTB and TU Ilmenau. In contrast to most Kibble balances, where the motion range is of up to several centimeters in the velocity mode, in the Planck-Balance it is below 100 μm. For a reliable determination of the force factor, the voice coil is set into harmonic oscillation, resulting in an induced AC voltage. The amplitude of the first harmonic is then taken to determine the force factor. However, due to the non-linear magnetic field across the motion range, the first harmonic is subject to a bias, and higher harmonics are excited. Those higher harmonics contain the information about the relative magnitude of the bias in the first harmonic, and can be used for a correction. In this paper we present an analytical model and show its application with real measurements. The estimated relative bias amounts to − 6.3 ⋅ 10 − 6 , with a residual relative uncertainty of 6.3 ⋅ 10 − 7 , for an oscillation amplitude of 20 μm. This method is especially of importance for Kibble balances with short motion range and working with harmonic oscillation. After such a correction is applied, a table-top version of a Kibble balance can be used as a conventional balance calibrated by means of E2 mass standards in the whole E2 class mass range.
- Open Access
- 9 March 2022
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 11 (1) , 75-82
Structure of digital metrological twins as software for uncertainty estimation
Ongoing digitalization in metrology and the ever-growing complexity of measurement systems have increased the effort required to create complex software for uncertainty estimation. To address this issue, a general structure for uncertainty estimation software will be presented in this work. The structure was derived from the Virtual Coordinate Measuring Machine (VCMM), which is a well-established tool for uncertainty estimation in the field of coordinate metrology. To make it easy to apply the software structure to specific projects, a supporting software library was created. The library is written in a portable and extensible way using the C++ programming language. The software structure and library proposed can be used in different domains of metrology. The library provides all the components necessary for uncertainty estimation (i.e., random number generators and GUM S1-compliant routines). Only the project-specific parts of the software must be developed by potential users. To verify the usability of the software structure and the library, a Virtual Planck-Balance, which is the digital metrological twin of a Kibble balance, is currently being developed.
- 9 March 2022
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 11 (1) , 75-82
Open AccessStructure of digital metrological twins as software for uncertainty estimation
Ongoing digitalization in metrology and the ever-growing complexity of measurement systems have increased the effort required to create complex software for uncertainty estimation. To address this issue, a general structure for uncertainty estimation software will be presented in this work. The structure was derived from the Virtual Coordinate Measuring Machine (VCMM), which is a well-established tool for uncertainty estimation in the field of coordinate metrology. To make it easy to apply the software structure to specific projects, a supporting software library was created. The library is written in a portable and extensible way using the C++ programming language. The software structure and library proposed can be used in different domains of metrology. The library provides all the components necessary for uncertainty estimation (i.e., random number generators and GUM S1-compliant routines). Only the project-specific parts of the software must be developed by potential users. To verify the usability of the software structure and the library, a Virtual Planck-Balance, which is the digital metrological twin of a Kibble balance, is currently being developed.
- Open Access
- 18 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12)
Frontmatter
Article Frontmatter was published on December 1, 2021 in the journal tm - Technisches Messen (volume 88, issue 12).
- 18 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12)
Open AccessFrontmatter