Melanie Schunemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Melanie Schunemann has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Karsten Sperlich
Department of Ophthalmology, Rostock University Medical Center, 18057 Rostock, Germany; Department Life, Light & Matter, University of Rostock 18059 Rostock, Germany
3 shared publications Heinrich Stolz
Institute of Physics, University of Rostock, Rostock, Germany
2 shared publicationsOliver Stachs
Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
2 shared publicationsAlexander Heisterkamp
Institute of Quantum Optics, Leibniz University Hannover, Hannover, Germany
1 shared publication- Alexander Heisterkamp
Institute of Quantum Optics, Leibniz University Hannover, Hannover, Germany
1 shared publication - Andrii Semenov
Bogolyubov Institute for Theoretical Physics
1 shared publication
Latest Publications
- 4 January 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (1) , 013701
Photocounting measurements with dead time and afterpulses in the continuous-wave regime
The widely used experimental technique of continuous-wave detection assumes counting pulses of photocurrent from a click-type detector inside a given measurement time window. With such a procedure we miss out the photons detected after each photocurrent pulse during the detector dead time. Additionally, each pulse may initialize a so-called afterpulse, which is not associated with the real photons. We derive the corresponding quantum photocounting formula and experimentally verify its validity. Statistics of photocurrent pulses appears to be nonlinear with respect to the quantum state, which is explained by the memory effect of the previous measurement time windows. Expressions—in general, nonlinear—connecting statistics of photons and pulses are derived for different measurement scenarios. We also consider an application of the obtained results to quantum state reconstruction with unbalanced homodyne detection.
- 4 January 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 109 (1) , 013701
Photocounting measurements with dead time and afterpulses in the continuous-wave regime
The widely used experimental technique of continuous-wave detection assumes counting pulses of photocurrent from a click-type detector inside a given measurement time window. With such a procedure we miss out the photons detected after each photocurrent pulse during the detector dead time. Additionally, each pulse may initialize a so-called afterpulse, which is not associated with the real photons. We derive the corresponding quantum photocounting formula and experimentally verify its validity. Statistics of photocurrent pulses appears to be nonlinear with respect to the quantum state, which is explained by the memory effect of the previous measurement time windows. Expressions—in general, nonlinear—connecting statistics of photons and pulses are derived for different measurement scenarios. We also consider an application of the obtained results to quantum state reconstruction with unbalanced homodyne detection.
- Open Access
- 19 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 75527-75535
Non-Invasive Full Rheological Characterization via Combined Speckle and Brillouin Microscopy
Rheology serves to measure the deformation and flow of materials. Its associated quantities, for example, the Young’s modulus, shear modulus, bulk modulus, or longitudinal modulus, are important in the biomedical field, in particular for soft materials, to characterize the response of materials to external force. Usually, mechanical probes, in particular rheometers or atomic force microscopy, are used to characterize these quantities. In the last decade, optical measurements have been derived to obtain these quantities even in small sample volumes. However, usually only one quantity is evaluated using optical techniques, such as Brillouin microscopy, which does not allow a full rheological characterization. The latter requires measuring at least two quantities, which allows for calculating all further rheological properties. In this paper, we aim to close this gap by combining two optical rheology methods, Brillouin microscopy to measure the longitudinal modulus and Laser Speckle Rheology for the shear modulus. We built an optical setup that allows the non-contact and hence non-destructive and non-invasive measurement of both quantities simultaneously in the same sample using a 780 nm, narrow linewidth (~50 kHz) laser system. We evaluate our approach using defined samples of glycerol and polydimethylsiloxane and we demonstrate image acquisition using the combined setup. We also investigate porcine corneae, as biological samples, and demonstrate direct measurement of longitudinal modulus and shear modulus and calculation of Young’s modulus, bulk modulus, and the Poission ratio, which are all in good agreement with published quantities. In the future, our approach allows for full characterization of the rheology of biological specimens.
- 19 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 75527-75535
Open AccessNon-Invasive Full Rheological Characterization via Combined Speckle and Brillouin Microscopy
Rheology serves to measure the deformation and flow of materials. Its associated quantities, for example, the Young’s modulus, shear modulus, bulk modulus, or longitudinal modulus, are important in the biomedical field, in particular for soft materials, to characterize the response of materials to external force. Usually, mechanical probes, in particular rheometers or atomic force microscopy, are used to characterize these quantities. In the last decade, optical measurements have been derived to obtain these quantities even in small sample volumes. However, usually only one quantity is evaluated using optical techniques, such as Brillouin microscopy, which does not allow a full rheological characterization. The latter requires measuring at least two quantities, which allows for calculating all further rheological properties. In this paper, we aim to close this gap by combining two optical rheology methods, Brillouin microscopy to measure the longitudinal modulus and Laser Speckle Rheology for the shear modulus. We built an optical setup that allows the non-contact and hence non-destructive and non-invasive measurement of both quantities simultaneously in the same sample using a 780 nm, narrow linewidth (~50 kHz) laser system. We evaluate our approach using defined samples of glycerol and polydimethylsiloxane and we demonstrate image acquisition using the combined setup. We also investigate porcine corneae, as biological samples, and demonstrate direct measurement of longitudinal modulus and shear modulus and calculation of Young’s modulus, bulk modulus, and the Poission ratio, which are all in good agreement with published quantities. In the future, our approach allows for full characterization of the rheology of biological specimens.
- Open Access
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 24340-24348
Balanced Heterodyne Brillouin Spectroscopy Towards Tissue Characterization
We present the first application of balanced heterodyne detection, established in quantum optics, to Brillouin spectroscopy in biological tissues. The balanced detection cancels out a large part of the influence of the laser noise. The center wavelength is 1064nm and the frequency resolution is 30MHz. The frequency resolution and the accessible frequency range are only limited by the measurement time and the laser tuning range (30GHz), respectively. In this way, we were able to measure the Brillouin shift in acetone, water, gummy bears, glass, and even porcine eye lenses.
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 24340-24348
Open AccessBalanced Heterodyne Brillouin Spectroscopy Towards Tissue Characterization
We present the first application of balanced heterodyne detection, established in quantum optics, to Brillouin spectroscopy in biological tissues. The balanced detection cancels out a large part of the influence of the laser noise. The center wavelength is 1064nm and the frequency resolution is 30MHz. The frequency resolution and the accessible frequency range are only limited by the measurement time and the laser tuning range (30GHz), respectively. In this way, we were able to measure the Brillouin shift in acetone, water, gummy bears, glass, and even porcine eye lenses.
- 1 February 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 1087-1101
Method for the generation and visualization of cross-sectional images of three-dimensional point spread functions for rotationally symmetric intraocular lenses
Cross-sectional images of three-dimensional point spread functions of intraocular lenses are used to study their image formation. To obtain those, light sheet-based methods are established. Due to the non-negligible thicknesses of the light sheets, the image quality of the cross-sectional images is constrained. To overcome this hurdle, we present a dedicated evaluation algorithm to increase image quality in the post-processing step. Additionally, we compare the developed- with the light sheet method based on our own investigations of a multifocal diffractive intraocular lens conducted in an in-house designed optical bench. The comparative study showed the clear superiority of the newly developed method in terms of image quality, fine structure visibility, and signal-to-noise ratio compared to the light sheet based method. However, since the algorithm assumes a rotationally symmetrical point spread function, it is only suitable for all rotationally symmetrical lenses.
- 1 February 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 1087-1101
Method for the generation and visualization of cross-sectional images of three-dimensional point spread functions for rotationally symmetric intraocular lenses
Cross-sectional images of three-dimensional point spread functions of intraocular lenses are used to study their image formation. To obtain those, light sheet-based methods are established. Due to the non-negligible thicknesses of the light sheets, the image quality of the cross-sectional images is constrained. To overcome this hurdle, we present a dedicated evaluation algorithm to increase image quality in the post-processing step. Additionally, we compare the developed- with the light sheet method based on our own investigations of a multifocal diffractive intraocular lens conducted in an in-house designed optical bench. The comparative study showed the clear superiority of the newly developed method in terms of image quality, fine structure visibility, and signal-to-noise ratio compared to the light sheet based method. However, since the algorithm assumes a rotationally symmetrical point spread function, it is only suitable for all rotationally symmetrical lenses.