XLXiandi Li

Xiandi Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiandi Li has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comprehensive multi-physics modeling of thermally sustained microdischarges at atmospheric pressure: A coupled PIC/MCC–DSMC approach

    by Pengze Xiao, Xiandi Li, Li Sun, Bocong Zheng, Wei Jiang, Hongyu Wang, Ya Zhang

    Optimization of microfluidic plasma devices hinges on accurate characterization of microscale plasma–fluid–thermal coupling, a process that cannot be reliably captured by traditional single-timescale models. Here, we develop a novel self-consistent model that couples particle-in-cell/Monte Carlo collision, direct simulation Monte Carlo, and thermal conduction modules, each operating on its own tailored timescale. This model enables 1 s steady-state simulations of atmospheric-pressure direct current argon microdischarges in a 100-μm gap with a hot tungsten cathode. Quantitative results reveal that inter-electrode gas thermal conduction (1.6×106 W m−2) plays a dominant role in governing the system energy balance, thermal state of the neutral gas, and overall discharge dynamics. A 30 K drop in cathode temperature (from 2400 to 2370 K) leads to a 14% decrease in discharge current and a 68% increase in plasma dynamic resistance. We demonstrate that time-resolved gas–electrode thermal interactions govern transient plasma dynamics and device thermal management, while also showing that conventional models with fixed temperature assumptions introduce non-negligible errors in predicting key plasma parameters. This coupled model provides a robust numerical framework for the design and optimization of thermally sustained microdischarge devices.

  • Effects of inductive and capacitive bias power on plasma parameters in inductively coupled radio frequency discharges

    by Xiandi Li, Zhaoyu Chen, Zili Chen, Li Wang, Yu Wang, Zhipeng Chen, Hongyu Wang, Wei Jiang, Julian Schulze, Ya Zhang

    A two-dimensional particle-in-cell/Monte Carlo collision simulation is performed to investigate a low-pressure inductively coupled plasma (ICP) operated in Neon at 27.12 MHz with a 13.56 MHz radio frequency (RF) substrate bias. In agreement with experimental observations, the results reveal coupling mechanisms between inductive power dissipation ( P ICP ) and capacitive RF power dissipation caused by the substrate bias ( P CCP ), which affect process relevant plasma parameters. P ICP affects the sheath voltage and plasma current, influencing the ion energy and angular distribution function and plasma series resonance oscillations. Even low values of P CCP alter the electron heating, EEPF, and plasma density. A high P ICP / P CCP ratio enhances ion directionality. Increasing pressure decreases the ion flux but increases ion energy through enhanced sheath voltage.


  • Open Access

    Two-dimensional PIC/MCC modeling of inductively coupled plasma: A benchmark study in the GEC configuration

    by Minglun Tian, Zhaoyu Chen, Zili Chen, Yu Wang, Xiandi Li, Zhipeng Chen, Yonghua Ding, Donghui Xia, Wei Jiang, Ya Zhang

    For inductively coupled plasma (ICP), accurately modeling power deposition and electron heating remains a fundamental challenge. This study presents a two-dimensional axisymmetric implicit particle-in-cell/Monte Carlo collision simulation of ICP in a Gaseous Electronics Conference reference cell, with a focus on the influence of high-order harmonic currents. By resolving harmonic-resolved electromagnetic fields, the simulation captures key nonlinear and nonlocal plasma behaviors under low-pressure conditions. Results reveal spatially nonuniform power deposition, electron energy probability function, and ion energy distribution function, emphasizing the importance of kinetic effects and higher harmonics in accurately modeling ICP discharges. The simulated electron density, temperature, and potential profiles align well with experimental data, validating the model. This work enhances the understanding of power coupling dynamics in ICP and provides insights for the design and optimization of plasma-based technologies such as semiconductor processing.


  • PIC/MCC simulations of the effects of a radio-frequency bias on inductively coupled plasmas

    by Xiandi Li, Zhaoyu Chen, Zili Chen, Yu Wang, Minglun Tian, Hongyu Wang, Zhipeng Chen, Wei Jiang, Julian Schulze, Ya Zhang

    The growing need for precision plasma processing has made radio frequency (RF) wafer biasing crucial for plasma parameter control. We developed a two-dimensional particle-in-cell/Monte Carlo collision model capable of simulating inductively coupled plasma (ICP) discharges, incorporating both electrode geometry and RF bias circuit coupling. The model was validated against experimental data from unbiased argon ICP discharges in a Gaseous Electronics Conference reference cell. With an increasing RF bias voltage within a certain range, the plasma density decreases nonlinearly and the electron energy probability function shifts toward low-energy populations, while the ion energy and angular distribution function at the wafer electrode transition from a single-peak structure to a double-peak structure with reduced angular dispersion. Further, equivalent impedance analysis reveals that the energy delivered to the plasma at the fundamental driving frequency is converted into energy generated in the plasma at higher harmonic frequencies through nonlinear mechanisms.


  • Breakdown mode and parameter space of micro-discharge sustained by thermionic emission

    by Xiandi Li, Hao Wu, Yujie Zhong, Chengzhi Guo, Lin Yi, Wei Jiang, Ya Zhang

    Gas breakdown driven by thermionic emission in a microgap to produce low-temperature plasma is studied using a 1D implicit particle-in-cell/Monte Carlo collision model. The influence of background gas pressure, external driving voltage, cathode temperature and discharge gap on argon glow micro-discharge in the parallel plate was simulated. Different parameters and conditions have different effects on the gas breakdown at small size. The discharge gap of hundreds of µm has little influence on the gas breakdown and only changes the plasma distribution. As the applied voltage increases, the gas changes from a non-breakdown mode to a breakdown mode, and the gas breakdown is more sensitive to the applied voltage than the gas pressure at low voltages. In all breakdown modes, the gas pressure hardly changes the plasma evolution characteristics. At appropriate cathode temperatures, the density of electrons and ions increases rapidly, forming a stable sheath, and the equivalent resistance of the discharge gap becomes smaller as the temperature rises and the plasma is in abnormal glow discharge.


  • The effects of match circuit on the breakdown process of capacitively coupled plasma driven by radio frequency

    by Hao Wu, Zhaoyu Chen, Shimin Yu, Qixuan Wang, Xiandi Li, Wei Jiang, Ya Zhang

    The breakdown process of capacitively coupled plasma (CCP) in the presence of a matching network is rarely studied, even though it is the indispensable part of the most laboratory and industrial devices of CCP. Based on the method of Verboncoeur, the solution method of the general “L”-type match circuit coupled with a particle-in-cell/Monte Carlo code is deduced self-consistently. Based on this method, the electrical breakdown process of CCP is studied. Both the plasma parameters and the electric parameters of the matching network during the breakdown are given and analyzed. In the pre-breakdown phase, the entire circuit can be considered as a linear system. However, the formation of the sheath during breakdown significantly enhanced the capacitance of the discharge chamber, which changed the electric signal amplitude of the external circuit. With the stabilization of plasma, the equivalent capacitance of CCP increases, which continues to change the electrical signal until the steady-state is reached. Accompanied by plasma stabilization is the appearance of high-order harmonics of discharge current caused by the gradually oscillating CCP capacitance. The breakdown characteristics can be obviously affected by the capacitance of the matching network. In the case of a breakdown zone, some breakdowns with special characteristics can be obtained by choosing the different capacitors. These works might be a reference for understanding the interaction between the plasma and the external circuit during the breakdown process and how to modulate the gas breakdown by controlling the external circuit.


  • Numerical characterization of the breakdown process of dc-driven micro-discharges sustained by thermionic emission

    by Yujie Zhong, Hao Wu, Xiandi Li, Jiamao Gao, Wei Jiang, Ya Zhang, Giovanni Lapenta

    Because of the larger surface-area-to-volume ratio, micro-discharges can be sustained by surface emission processes. If the cathode is heated, a micro-discharge can be sustained mainly by thermionic emission. However, we still know little about how this kind of plasma is ignited and sustained. In order to explore the breakdown process of dc-driven micro-discharge sustained by thermionic emission, a one-dimensional implicit particle-in-cell/Monte Carlo collision method is adopted, coupled with the external circuit and thermionic emission model. The breakdown process of micro-discharge lasts about 8 μ s , and this process can be roughly divided into two phases, i.e. pre-breakdown and breakdown phase. The dynamic plasma parameters during the evolution process are analyzed, such as particle density, electron energy distribution function, electric potential, average particle temperature, and particle current density. The plasma electrical characteristics as well as the article and power balance, are also presented to show the evolutionary features of the whole gas breakdown process.