NNNur Shahira Abdul Nasir

Nur Shahira Abdul Nasir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nur Shahira Abdul Nasir has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Integration of Dielectrophoresis Mechanisms With Capacitance Measurement for Bovine Serum Albumin (BSA) Manipulation

    by Nur Shahira Abdul Nasir, Muhammad Khairulanwar Abdul Rahim, Azrul Azlan Hamzah, Aminuddin Ahmad Kayani, Mei Xian Low, M. F. Mohd Razip Wee, Abdullah Abdulhameed, Céline Élie-Caille, Muhamad Ramdzan Buyong

    Dielectrophoresis (DEP) is a technique that leverages the dielectric properties of molecules for manipulation to study their behavior under the influence of non-uniform electric fields. The aim of this research is to make a correlation of capacitance change to the DEP response, which is determined by the CMf plot. Second, we aim to make a comparison of the capacitance change in biological molecules and engineered particles. Thirdly, the optimization of the ideal geometry of the integrated microelectrodes for the most optimal capacitance change value. The numerical simulations results reveal that both BSA and the polystyrene beads (PS) exhibit a crossover frequency (fxo) transitioning from positive-DEP (pDEP) to negative-DEP (nDEP). We conduct an experimental DEP-based actuator on both BSA and PS while measuring the capacitance of the DEP response. For further validation of the capacitance measurement, we conduct an experiment on different widths, d1= 16 μm, d2 = 20.5 μm and d3 = 25 μm, of capacitance microelectrodes. Result has proved that the fxo for BSA and PS are determined to be 2.63 MHz and 411.98 kHz. The capacitance change variation value for BSA is determined to be higher than PS where the coefficient of variation (CV) value for BSA is 1 .3814 and for PS is 0.8528. Result from the validation for different capacitance microelectrode widths shows that 25 μm has the most optimal mechanical geometry. In conclusion, this study presents an investigation of the DEP based actuator response of BSA can be used for detection of various biomolecules.


  • A correlation of conductivity medium and bioparticle viability on dielectrophoresis‐based biomedical applications

    by Revathy Deivasigamani, Nur Nasyifa Mohd Maidin, Nur Shahira Abdul Nasir, Abdullah Abdulhameed, Aminuddin Bin Ahmad Kayani, Mohd Ambri Mohamed, Muhamad Ramdzan Buyong

    Dielectrophoresis (DEP) bioparticle research has progressed from micro to nano levels. It has proven to be a promising and powerful cell manipulation method with an accurate, quick, inexpensive, and label‐free technique for therapeutic purposes. DEP, an electrokinetic phenomenon, induces particle movement as a result of polarization effects in a nonuniform electrical field. This review focuses on current research in the biomedical field that demonstrates a practical approach to DEP in terms of cell separation, trapping, discrimination, and enrichment under the influence of the conductive medium in correlation with bioparticle viability. The current review aims to provide readers with an in‐depth knowledge of the fundamental theory and principles of the DEP technique, which is influenced by conductive medium and to identify and demonstrate the biomedical application areas. The high conductivity of physiological fluids presents obstacles and opportunities, followed by bioparticle viability in an electric field elaborated in detail. Finally, the drawbacks of DEP‐based systems and the outlook for the future are addressed. This article will aid in advancing technology by bridging the gap between bioscience and engineering. We hope the insights presented in this review will improve cell suspension medium and promote DEP‐viable bioparticle manipulation for health‐care diagnostics and therapeutics.


  • A dielectrophoresis proof of concept of polystyrene particles and in‐vitro human epidermal keratinocytes migration for wound rejuvenation

    by Revathy Deivasigamani, Nur Nasyifa Mohd Maidin, Nur Shahira Abdul Nasir, Mei Xian Low, Aminuddin Bin Ahmad Kayani, Mohd Ambri Mohamed, Muhamad Ramdzan Buyong

    Diabetes affects approximately 170 million people worldwide, is expected to double by 2030, and is a severe problem. Electrical stimulation (ES) via dielectrophoresis (DEP) technique may be an effective alternative in enhancing healing rates in diabetic patients with open ulcers. This research used DEP force (FDEP) to manipulate 3.2, 4.8, 10, and 15 μm polystyrene (PS) particles to predict the migration capability of human epidermal keratinocytes (HEKs). A numerical modeling method, MyDEP, was used to predict the interpretation of Clausius–Mossotti factors of PS particles and HEKs. The finite element method computes the electric field intensity and particle trajectory based on DEP and drag forces in their respective medium. DEP experiments on numerous size PS particles and alive HEKs were carried out in a tapered aluminium microelectrode array using a non‐uniform electric field. The distinct PS particles exhibit positive DEP (PDEP), crossover frequency (fXO), and negative DEP (NDEP), whereas the HEKs experience, only NDEP due to its high conductive medium in frequency ranges from 100 kHz to 1 MHz. Finally, the DIPP‐MotionV analysis shows that particle mobility between speed and acceleration is statistically considerable. When an appropriate frequency is applied to HEKs in random locations, the FDEP aligns at the desired target position based on its dielectric properties, which accelerates wound healing in in‐vivo conditions.


  • Open Access

    Protein Albumin Manipulation and Electrical Quantification of Molecular Dielectrophoresis Responses for Biomedical Applications

    by Nur Shahira Abdul Nasir, Revathy Deivasigamani, M. F. Mohd Razip Wee, Azrul Azlan Hamzah, Mohd Hazani Mat Zaid, Muhammad Khairulanwar Abdul Rahim, Aminuddin Ahmad Kayani, Abdullah Abdulhameed, Muhamad Ramdzan Buyong

    Research relating to dielectrophoresis (DEP) has been progressing rapidly through time as it is a strong and controllable technique for manipulation, separation, preconcentration, and partitioning of protein. Extensive studies have been carried out on protein DEP, especially on Bovine Serum Albumin (BSA). However, these studies involve the usage of dye and fluorescent probes to observe DEP responses as the physical properties of protein albumin molecular structure are translucent. The use of dye and the fluorescent probe could later affect the protein’s physiology. In this article, we review three methods of electrical quantification of DEP responses: electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and capacitance measurement for protein BSA DEP manipulation. The correlation of these methods with DEP responses is further discussed. Based on the observations on capacitance measurement, it can be deduced that the electrical quantifying method is reliable for identifying DEP responses. Further, the possibility of manipulating the protein and electrically quantifying DEP responses while retaining the original physiology of the protein and without the usage of dye or fluorescent probe is discussed.


  • In vitro dielectrophoresis of HEK cell migration for stimulating chronic wound epithelialization

    by Revathy Deivasigamani, Nur Shahira Abdul Nasir, Mohd Ambri Mohamed, Muhamad Ramdzan Buyong

    This article describes a dielectrophoresis (DEP)‐based simulation and experimental study of human epidermal keratinocyte (HEK) cells for wounded skin cell migration toward rapid epithelialization. MyDEP is a standalone software designed specifically to study dielectric particles and cell response to an alternating current (AC) electric field. This method demonstrated that negative dielectrophoresis (NDEP) occurs in HEK cells at a wide frequency range in highly conductive medium. The finite element method was used to characterize particle trajectory based on DEP and drag force. The performance of the system was assessed using HEK cells in a highly conductive EpiLife suspending medium. The DEP experiment was performed by applying sinusoidal wave AC potential at the peak‐to‐peak voltage of 10 V in a tapered aluminum microelectrode array from 100 kHz to 1 MHz. We experimentally observed the occurrence of NDEP, which attracted HEK cells toward the local electric field minima in the region of interest. The DIPP‐MotionV software was used to track cell migration in the prerecorded video via an automatic marker and estimate the average speed and acceleration of the cells. The results showed that HEK cell migration was accomplished approximately at 6.43 μm/s at 100 kHz with 10 V, and FDEP caused the cells to migrate and align at the target position, which resulted in faster wound closures because of the application of an electric field frequency to HEK cells in random locations.