Zibo Zhuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zibo Zhuang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Chengduo Yuan
Department of Flight Area Management Harbin International Airport Co., Ltd Harbin China
1 shared publicationHongda Tai
Flight Academy of CAUC Civil Aviation University of China Tianjin China
1 shared publicationJinfeng Li
Flight Academy of CAUC Civil Aviation University of China Tianjin China
1 shared publication- Pak Wai Chan
Hong Kong Observatory, Hong Kong, China
1 shared publication - Xin Zhang
Flight Academy of Civil Aviation University of China Tianjin China
1 shared publication - Yue Wang
College of Safety Science and Engineering Civil Aviation University of China Tianjin China
1 shared publication
Latest Publications
- Open Access
- 28 May 2024
- Published by Wiley in Meteorological Applications
- Vol. 31 (3)
Influence of aerosol–meteorology interactions on visibility during a wintertime heavily polluted episode in Central‐East, China
Atmospheric visibility profoundly impacts daily life, and accurate prediction is crucial, particularly in conditions of low visibility characterized by high aerosol loading and humidity. This study employed the WRF‐Chem model to simulate a severe wintertime haze pollution episode that transpired from January 17 to 19, 2010, in Central‐East China (112–122° E, 34–42° N). The results reveal that excluding aerosol–meteorology interactions led to underestimated PM2.5 concentrations and relative humidity in comparison with ground‐based measurement data, accompanied by a significant overestimation of visibility. Aerosols can engage with meteorological elements, particularly humidity, resulting in positive feedback. Upon considering these feedback interactions, the simulation results showed an increase of 5.17% and 1.99% in PM2.5 concentration and relative humidity, respectively, compared with the original simulation. This adjustment narrowed the bias between simulated and measured data. The overestimation of simulated visibility was reduced by 16% and 25% for the entire study period and the severe haze pollution period, respectively. These findings underscore the vital role of incorporating aerosol–meteorology interactions in visibility simulations using the WRF‐Chem model. Notably, the inclusion of aerosol–meteorological feedback significantly enhances the accuracy of visibility predictions, particularly during heavily polluted periods.
- 28 May 2024
- Published by Wiley in Meteorological Applications
- Vol. 31 (3)
Open AccessInfluence of aerosol–meteorology interactions on visibility during a wintertime heavily polluted episode in Central‐East, China
Atmospheric visibility profoundly impacts daily life, and accurate prediction is crucial, particularly in conditions of low visibility characterized by high aerosol loading and humidity. This study employed the WRF‐Chem model to simulate a severe wintertime haze pollution episode that transpired from January 17 to 19, 2010, in Central‐East China (112–122° E, 34–42° N). The results reveal that excluding aerosol–meteorology interactions led to underestimated PM2.5 concentrations and relative humidity in comparison with ground‐based measurement data, accompanied by a significant overestimation of visibility. Aerosols can engage with meteorological elements, particularly humidity, resulting in positive feedback. Upon considering these feedback interactions, the simulation results showed an increase of 5.17% and 1.99% in PM2.5 concentration and relative humidity, respectively, compared with the original simulation. This adjustment narrowed the bias between simulated and measured data. The overestimation of simulated visibility was reduced by 16% and 25% for the entire study period and the severe haze pollution period, respectively. These findings underscore the vital role of incorporating aerosol–meteorology interactions in visibility simulations using the WRF‐Chem model. Notably, the inclusion of aerosol–meteorological feedback significantly enhances the accuracy of visibility predictions, particularly during heavily polluted periods.
- Open Access
- 3 March 2022
- Published by Wiley in Meteorological Applications
- Vol. 29 (2)
Substitutability research for forward‐scatter meters in indoor low‐visibility environments
Visibility is a crucial parameter for aeronautical operations. Forward‐scatter meters are recommended to measure it because of inherent advantages. With wide use at airports, the substitutability among forward‐scatter meters is worth paying attention to, especially in low‐visibility environments. To confirm the substitutability among forward‐scatter meters, eight kinds of forward‐scatter meters were installed in an indoor atmospheric environment simulation chamber. The observed values of each of the eight forward‐scatter meters in haze and smoke low‐visibility environments were collected. By least‐squares fitting analysis and the ATE/LER zones method, in the haze, the two sets of CS125 can be substituted for each other in visibilities lower than 2000 m. PWD20 and V30 can be substituted for each other at visibilities lower than approximately 1200 m. From 1200 to 2000 m, the consistency of the two instruments is poor. In the smoke, CS125 and PWD20 display good substitutability with each other when visibility is less than 2000 m. If only focusing on visibilities less than approximately 1000 m, the VPF‐710 and V30 instruments can be substituted with each other.
- 3 March 2022
- Published by Wiley in Meteorological Applications
- Vol. 29 (2)
Open AccessSubstitutability research for forward‐scatter meters in indoor low‐visibility environments
Visibility is a crucial parameter for aeronautical operations. Forward‐scatter meters are recommended to measure it because of inherent advantages. With wide use at airports, the substitutability among forward‐scatter meters is worth paying attention to, especially in low‐visibility environments. To confirm the substitutability among forward‐scatter meters, eight kinds of forward‐scatter meters were installed in an indoor atmospheric environment simulation chamber. The observed values of each of the eight forward‐scatter meters in haze and smoke low‐visibility environments were collected. By least‐squares fitting analysis and the ATE/LER zones method, in the haze, the two sets of CS125 can be substituted for each other in visibilities lower than 2000 m. PWD20 and V30 can be substituted for each other at visibilities lower than approximately 1200 m. From 1200 to 2000 m, the consistency of the two instruments is poor. In the smoke, CS125 and PWD20 display good substitutability with each other when visibility is less than 2000 m. If only focusing on visibilities less than approximately 1000 m, the VPF‐710 and V30 instruments can be substituted with each other.