Tao Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tao Peng has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Jinhua Zhou
School of Biomedical Engineering Anhui Medical University Hefei China
5 shared publications Meng Shao
Hefei University of Technology
3 shared publicationsShengzhao Zhang
Anhui Medical University
3 shared publicationsShu Fang
3 shared publicationsFengsong Wang
2 shared publicationsJun He
Anhui Medical University
2 shared publications
Latest Publications
- Open Access
- 16 May 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (10) , 1766
SSAformer: Spatial–Spectral Aggregation Transformer for Hyperspectral Image Super-Resolution
The hyperspectral image (HSI) distinguishes itself in material identification through its exceptional spectral resolution. However, its spatial resolution is constrained by hardware limitations, prompting the evolution of HSI super-resolution (SR) techniques. Single HSI SR endeavors to reconstruct high-spatial-resolution HSI from low-spatial-resolution inputs, and recent progress in deep learning-based algorithms has significantly advanced the quality of reconstructed images. However, convolutional methods struggle to extract comprehensive spatial and spectral features. Transformer-based models have yet to harness long-range dependencies across both dimensions fully, thus inadequately integrating spatial and spectral data. To solve the above problem, in this paper, we propose a new HSI SR method, SSAformer, which merges the strengths of CNNs and Transformers. It introduces specially designed attention mechanisms for HSI, including spatial and spectral attention modules, and overcomes the previous challenges in extracting and amalgamating spatial and spectral information. Evaluations on benchmark datasets show that SSAformer surpasses contemporary methods in enhancing spatial details and preserving spectral accuracy, underscoring its potential to expand HSI’s utility in various domains, such as environmental monitoring and remote sensing.
- 16 May 2024
- Published by MDPI AG in Remote Sensing
- Vol. 16 (10) , 1766
Open AccessSSAformer: Spatial–Spectral Aggregation Transformer for Hyperspectral Image Super-Resolution
The hyperspectral image (HSI) distinguishes itself in material identification through its exceptional spectral resolution. However, its spatial resolution is constrained by hardware limitations, prompting the evolution of HSI super-resolution (SR) techniques. Single HSI SR endeavors to reconstruct high-spatial-resolution HSI from low-spatial-resolution inputs, and recent progress in deep learning-based algorithms has significantly advanced the quality of reconstructed images. However, convolutional methods struggle to extract comprehensive spatial and spectral features. Transformer-based models have yet to harness long-range dependencies across both dimensions fully, thus inadequately integrating spatial and spectral data. To solve the above problem, in this paper, we propose a new HSI SR method, SSAformer, which merges the strengths of CNNs and Transformers. It introduces specially designed attention mechanisms for HSI, including spatial and spectral attention modules, and overcomes the previous challenges in extracting and amalgamating spatial and spectral information. Evaluations on benchmark datasets show that SSAformer surpasses contemporary methods in enhancing spatial details and preserving spectral accuracy, underscoring its potential to expand HSI’s utility in various domains, such as environmental monitoring and remote sensing.
- 21 February 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (3) , 1785-1797
Plug-and-play DPC-based quantitative phase microscope
Point-of-care testing (POCT) plays an increasingly important role in biomedical research and health care. Quantitative phase microscopes (QPMs) with good contrast, no invasion, no labeling, high speed and automation could be effectively applied for POCT. However, most QPMs are fixed on the optical platform with bulky size, lack of timeliness, which remained challenging in POCT solutions. In this paper, we proposed a plug-and-play QPM with multimode imaging based on the quantitative differential phase contrast (qDPC) method. The system employs a programmable LED array as the light source and uses the GPU to accelerate the calculation, which can realize multi-contrast imaging with six modes. Accurate phase measurement and real-time phase imaging are implemented by the proposed qDPC algorithms for quantitative phase targets and biomedical samples. A 3D electric control platform is designed for mechanical control of field of view and focusing without manual operations. The experimental results verify the robustness and high performance of the setup. Even a rookie could finish the POCT scheme for biomedical applications at the scene using the QPM with a compact size of 140 × 165 × 250 mm3.
- 21 February 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (3) , 1785-1797
Plug-and-play DPC-based quantitative phase microscope
Point-of-care testing (POCT) plays an increasingly important role in biomedical research and health care. Quantitative phase microscopes (QPMs) with good contrast, no invasion, no labeling, high speed and automation could be effectively applied for POCT. However, most QPMs are fixed on the optical platform with bulky size, lack of timeliness, which remained challenging in POCT solutions. In this paper, we proposed a plug-and-play QPM with multimode imaging based on the quantitative differential phase contrast (qDPC) method. The system employs a programmable LED array as the light source and uses the GPU to accelerate the calculation, which can realize multi-contrast imaging with six modes. Accurate phase measurement and real-time phase imaging are implemented by the proposed qDPC algorithms for quantitative phase targets and biomedical samples. A 3D electric control platform is designed for mechanical control of field of view and focusing without manual operations. The experimental results verify the robustness and high performance of the setup. Even a rookie could finish the POCT scheme for biomedical applications at the scene using the QPM with a compact size of 140 × 165 × 250 mm3.
- Open Access
- 19 October 2023
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 143, 105441
Full-scale experiments on the fire smoke extraction from naturally ventilated shafts for shallow-buried urban road tunnels in hot summer
- 19 October 2023
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 143, 105441
Open AccessFull-scale experiments on the fire smoke extraction from naturally ventilated shafts for shallow-buried urban road tunnels in hot summer
- Open Access
- 14 January 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 163
Quantitative differential phase contrast phase reconstruction for sparse samples
- 14 January 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 163
Open AccessQuantitative differential phase contrast phase reconstruction for sparse samples
- 27 August 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (12) , e202200122
An apparatus for qualitative assessment of the shading ratio of oblique illumination and real‐time high‐contrast imaging
Oblique illumination imaging can significantly improve the contrast of transparent thin samples. However, in traditional oblique illumination methods, either the condenser is offset or a block is added to the condenser, which makes it complicated and challenged to build a stable oblique illumination imaging. Herein, we present a method to measure the optimal shading ratio of oblique illumination in an inverted microscope, and develop an apparatus for stable high‐speed high‐contrast imaging with uniform brightness. At optimal shading ratio, the oblique illumination imaging has better imaging quality than differential interference contrast, which characteristic is independent on sample. In oblique illumination with low magnification objective, the images have uneven brightness. According to target brightness, we have developed a brightness unevenness correction algorithm to form uniform background brightness for oblique illumination. Integrating the algorithm with imaging acquisition, corrected oblique illumination microscopy is appropriate to observe living cells with high contrast.
- 27 August 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (12) , e202200122
An apparatus for qualitative assessment of the shading ratio of oblique illumination and real‐time high‐contrast imaging
Oblique illumination imaging can significantly improve the contrast of transparent thin samples. However, in traditional oblique illumination methods, either the condenser is offset or a block is added to the condenser, which makes it complicated and challenged to build a stable oblique illumination imaging. Herein, we present a method to measure the optimal shading ratio of oblique illumination in an inverted microscope, and develop an apparatus for stable high‐speed high‐contrast imaging with uniform brightness. At optimal shading ratio, the oblique illumination imaging has better imaging quality than differential interference contrast, which characteristic is independent on sample. In oblique illumination with low magnification objective, the images have uneven brightness. According to target brightness, we have developed a brightness unevenness correction algorithm to form uniform background brightness for oblique illumination. Integrating the algorithm with imaging acquisition, corrected oblique illumination microscopy is appropriate to observe living cells with high contrast.
- Open Access
- 12 April 2022
- Published by MDPI AG in Preprints.org
A Compact Real-time Quantitative Phase Imaging System
Quantitative differential phase contrast (qDPC) imaging has become an important method of optical measurement and life science research in microscopy because of its high reconstruction resolution and non-invasive, high-contrast and quantitative imaging of biological samples. Despite the continuous development of the principle and algorithm, the frame rate of the existing qDPC algorithm is still much lower than that of camera acquisition, so it is hardly applied to real-time image the fast-moving biological samples. In this paper, based on color-coded multiplexing strategy, a compact real-time quantitative phase imaging system is designed to realize multi-mode imaging. The system employs a programmable LED array to illuminate directly, and the phase reconstruction algorithm is deployed in the graphics processing unit (GPU) of the laptop to accelerate the calculation. The system can achieve high-speed quantitative phase imaging of non-stained biological samples, and the frame rate can reach 60fps. The device has the advantages of compact structure, low cost and portability. Thus, it is suitable for mobile medical applications.
- 12 April 2022
- Published by MDPI AG in Preprints.org
Open AccessA Compact Real-time Quantitative Phase Imaging System
Quantitative differential phase contrast (qDPC) imaging has become an important method of optical measurement and life science research in microscopy because of its high reconstruction resolution and non-invasive, high-contrast and quantitative imaging of biological samples. Despite the continuous development of the principle and algorithm, the frame rate of the existing qDPC algorithm is still much lower than that of camera acquisition, so it is hardly applied to real-time image the fast-moving biological samples. In this paper, based on color-coded multiplexing strategy, a compact real-time quantitative phase imaging system is designed to realize multi-mode imaging. The system employs a programmable LED array to illuminate directly, and the phase reconstruction algorithm is deployed in the graphics processing unit (GPU) of the laptop to accelerate the calculation. The system can achieve high-speed quantitative phase imaging of non-stained biological samples, and the frame rate can reach 60fps. The device has the advantages of compact structure, low cost and portability. Thus, it is suitable for mobile medical applications.
- 13 March 2022
- Published by Wiley in Cytometry Part A
- Vol. 101 (8) , 648-657
Morphology analysis of unlabeled red blood cells based on quantitative differential phase contrast microscopy
The current classical blood smear technique to observe the morphology of single red blood cells (RBCs) for classification is a laborious and error‐prone process. To objectively evaluate the morphology of blood cells, we established a method of computational imaging based on a programmable light emitting diode array. By using quantitative differential phase contrast (qDPC), we characterized the morphology of unlabeled RBCs as well as blood smears. By focusing on comparing the difference of imaging between unlabeled RBCs and stained RBCs under multimode microscopic imaging technology, we demonstrated that qDPC could clearly differentiate discocytes and spherocytes in both unlabeled RBCs and blood smears. The phase map provided by quantitative phase imaging further enhanced the classification accuracy. According to statistical analysis from morphological indexes, the qDPC imaging has a significantly improvement in non‐circularity, texture inhomogeneity and equivalent diameters of cells. Thus, this method has a significant superiority in the capability to analyze the morphology of RBCs and could be applied to clinical assays for determining morphological, functional, and structural deterioration of RBCs.
- 13 March 2022
- Published by Wiley in Cytometry Part A
- Vol. 101 (8) , 648-657
Morphology analysis of unlabeled red blood cells based on quantitative differential phase contrast microscopy
The current classical blood smear technique to observe the morphology of single red blood cells (RBCs) for classification is a laborious and error‐prone process. To objectively evaluate the morphology of blood cells, we established a method of computational imaging based on a programmable light emitting diode array. By using quantitative differential phase contrast (qDPC), we characterized the morphology of unlabeled RBCs as well as blood smears. By focusing on comparing the difference of imaging between unlabeled RBCs and stained RBCs under multimode microscopic imaging technology, we demonstrated that qDPC could clearly differentiate discocytes and spherocytes in both unlabeled RBCs and blood smears. The phase map provided by quantitative phase imaging further enhanced the classification accuracy. According to statistical analysis from morphological indexes, the qDPC imaging has a significantly improvement in non‐circularity, texture inhomogeneity and equivalent diameters of cells. Thus, this method has a significant superiority in the capability to analyze the morphology of RBCs and could be applied to clinical assays for determining morphological, functional, and structural deterioration of RBCs.