Alessandro Maselli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alessandro Maselli has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Tommaso Ciapetti
Institute of Recovery and Care of Scientific Character (IRCCS), Fondazione Don Carlo Gnocchi, Florence, Italy
2 shared publications - Andrea Baldoni
The BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
1 shared publication - Andrea Pergolini
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
1 shared publication - Carolina Giustinoni
Scuola di Ingegneria, Università di Pisa, 56126 Pisa, Italy
1 shared publication - Cesare Stefanini
Mohamed bin Zayed University of Artificial Intelligence
1 shared publication - Chiara Livolsi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
1 shared publication
Latest Publications
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 5550-5563
A Unilateral Active Knee Exoskeleton to Assist Individuals With Hemiparesis—A Pilot Study
Most individuals who experience a stroke exhibit several sensorimotor impairments that limit their independence in everyday activities. Hemiparetic gait is frequently characterized by reduced knee flexion in swing due to knee stiffness or muscle weakness and knee hyperextension or knee buckling in the stance phase. Recently, unilateral-powered orthoses have been designed to overcome the limitations of the passive knee-ankle-foot orthoses. This study presents a unilateral Active Knee Orthosis Exoskeleton, AKO-$\beta$, endowed with a series elastic actuator and designed to assist the knee in flexion and extension movements. The paper describes the system mechatronic design and its characterization on the bench, the control system, and pilot experiments with three post-stroke participants. The device has a weight of 1.78 kg on the user's leg, with a lateral encumbrance of 76 mm. The pilot experiments aimed to verify the effects of the exoskeleton assistance in hemiparetic gait patterns. When walking with the device, participants on average increased the knee flexion on the paretic side by 18.70 deg (+44.9%) during swing and decreased knee hyperextension in stance by 4.50 deg, compared to walking without it. Overall, when walking with the exoskeleton, subjects showed improved Gait Variable Score of the paretic knee profile by 37.5% compared to walking without it. The temporal and spatial gait symmetry indexes did not show clear changes, although an improvement in symmetry was observed in two of the three participants. These preliminary results suggest the potential benefits of the unilateral Active Knee Orthosis exoskeleton to enhance and restore mobility in individuals with hemiparetic gait.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 5550-5563
A Unilateral Active Knee Exoskeleton to Assist Individuals With Hemiparesis—A Pilot Study
Most individuals who experience a stroke exhibit several sensorimotor impairments that limit their independence in everyday activities. Hemiparetic gait is frequently characterized by reduced knee flexion in swing due to knee stiffness or muscle weakness and knee hyperextension or knee buckling in the stance phase. Recently, unilateral-powered orthoses have been designed to overcome the limitations of the passive knee-ankle-foot orthoses. This study presents a unilateral Active Knee Orthosis Exoskeleton, AKO-$\beta$, endowed with a series elastic actuator and designed to assist the knee in flexion and extension movements. The paper describes the system mechatronic design and its characterization on the bench, the control system, and pilot experiments with three post-stroke participants. The device has a weight of 1.78 kg on the user's leg, with a lateral encumbrance of 76 mm. The pilot experiments aimed to verify the effects of the exoskeleton assistance in hemiparetic gait patterns. When walking with the device, participants on average increased the knee flexion on the paretic side by 18.70 deg (+44.9%) during swing and decreased knee hyperextension in stance by 4.50 deg, compared to walking without it. Overall, when walking with the exoskeleton, subjects showed improved Gait Variable Score of the paretic knee profile by 37.5% compared to walking without it. The temporal and spatial gait symmetry indexes did not show clear changes, although an improvement in symmetry was observed in two of the three participants. These preliminary results suggest the potential benefits of the unilateral Active Knee Orthosis exoskeleton to enhance and restore mobility in individuals with hemiparetic gait.
- Open Access
Assessing Respiratory Activity by Using IMUs: Modeling and Validation
This study aimed to explore novel inertial measurement unit (IMU)-based strategies to estimate respiratory parameters in healthy adults lying on a bed while breathing normally. During the experimental sessions, the kinematics of the chest wall were contemporaneously collected through both a network of 9 IMUs and a set of 45 uniformly distributed reflective markers. All inertial kinematics were analyzed to identify a minimum set of signals and IMUs whose linear combination best matched the tidal volume measured by optoelectronic plethysmography. The resulting models were finally tuned and validated through a leave-one-out cross-validation approach to assess the extent to which they could accurately estimate a set of respiratory parameters related to three trunk compartments. The adopted methodological approach allowed us to identify two different models. The first, referred to as Model 1, relies on the 3D acceleration measured by three IMUs located on the abdominal compartment and on the lower costal margin. The second, referred to as Model 2, relies on only one component of the acceleration measured by two IMUs located on the abdominal compartment. Both models can accurately estimate the respiratory rate (relative error < 1.5%). Conversely, the duration of the respiratory phases and the tidal volume can be more accurately assessed by Model 2 (relative error < 5%) and Model 1 (relative error < 5%), respectively. We further discuss possible approaches to overcome limitations and improve the overall accuracy of the proposed approach.
Open AccessAssessing Respiratory Activity by Using IMUs: Modeling and Validation
This study aimed to explore novel inertial measurement unit (IMU)-based strategies to estimate respiratory parameters in healthy adults lying on a bed while breathing normally. During the experimental sessions, the kinematics of the chest wall were contemporaneously collected through both a network of 9 IMUs and a set of 45 uniformly distributed reflective markers. All inertial kinematics were analyzed to identify a minimum set of signals and IMUs whose linear combination best matched the tidal volume measured by optoelectronic plethysmography. The resulting models were finally tuned and validated through a leave-one-out cross-validation approach to assess the extent to which they could accurately estimate a set of respiratory parameters related to three trunk compartments. The adopted methodological approach allowed us to identify two different models. The first, referred to as Model 1, relies on the 3D acceleration measured by three IMUs located on the abdominal compartment and on the lower costal margin. The second, referred to as Model 2, relies on only one component of the acceleration measured by two IMUs located on the abdominal compartment. Both models can accurately estimate the respiratory rate (relative error < 1.5%). Conversely, the duration of the respiratory phases and the tidal volume can be more accurately assessed by Model 2 (relative error < 5%) and Model 1 (relative error < 5%), respectively. We further discuss possible approaches to overcome limitations and improve the overall accuracy of the proposed approach.