KCKwang Jin Choi

Kwang Jin Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kwang Jin Choi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of Glucose in Brain Cells and Body Fluids Using Skin Tattoo Painting Wearalble Circuit with Modified Carbon Nanotube Microprobes

    by Kyung Lee, Suw Young Ly, Kwang Jin Choi, Jinhyeok Park

    In-vivo diabetes detection of glucose was sought using square-wave anodic stripping voltammetry (SW), with bismuth-immobilized carbon nanotube paste electrode (BCE), and skin tattoo painted wearable circuits. The optimum analytical results indicated sensitivity of 0.0781 μg/L peak signals on the BCE. The raw voltammogram was approached within the in vivo detection ranges of 10–90 μg/L, with preconcentration times of 50 s attained. The relative standard deviation was micro ranges under optimum conditions. The analytical detection limit (S/N) was attained at a nano range of 5.5 nM. The handmade microsensor was directly used in vivo on the living fish brain and human urine. The method was applied at real time in vivo, without requiring any pretreatment and other ionic electrolyte solutions. It can be used for medicinal and other materials requiring biological-fluid detection in real time. This study was designed to be suitable for real-time unmanned remote diagnosis and therapeutic drug injection into the body, micro-needle long-term administration, wearable artificial skin tattoo sensor, and real-time control. In addition, the glasses monitor was designed to be suitable for multitasking and multi-user control sensing.

  • Trace assay of insulin in a pharmacy drug with a paste electrode

    by In Hea Cho, Kwang Jin Choi, Jongwan Choi, Kyung Lee, Suw Young Ly

    This paper describes the development of a voltammetric assay of insulin using a DNA immobilized onto a carbon nanotube paste electrode (CNPE), the peak potential of which was 0.2 V, vs. Ag/AgCl on the CNPE. The cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry parameters of the optimized conditions were determined. Low analytical working ranges of 10–80 ugL−1 CV and 0.01–0.1 ngL−1 SW were attained. The precision of the insulin concentration of 0.01 ugL−1 was 0.14 (n = 15) RSD using the optimum conditions, in which the detection limit was 0.004 ngL−1 (6.9 × 10–12 M) (S/N = 3) using only an accumulation time of 400 s. The developed method was applied to determine insulin in a pharmacy drug from analytical-grade chemicals (from Aldrich).


  • Open Access

    Analysis of Staphylococcus aureus Molecules in Non-Treated Blood Using Mercury Immobilized Carbon Nanotube Sensor

    by In Hea Cho, Kwang Jin Choi, Ji Hyun Kim, Kyung Lee, Suw Young Ly

    Staphylococcus aureus bacteria is a ubiquitous Gram-positive microorganism that causes infections related to the sudden infant death syndrome. Recently, basic detection methods depend on complicated PCR amplification, electric separation, spectric adsorption and other detection systems. However, in this study, simplified sensitive voltammetric skills are developed. To identify an effective diagnostic method for Staphylococcus aureus (SA), a voltammetric sensing probe was sought using mercury immobilized on a carbon nanotube sensor (MCN). The voltammetric MCN conditions were optimized through stripping and cyclic voltammetry. Diagnostic electrolyte was used on non-treated blood sera as an electrolyte solution. The optimum cyclic and stripping analytical working range was 0.5–4.0 mL (3 × 102~5 × 102 CFU/0.5 mL) SA. The statistic relative standard deviation of 0.1 mL SA was observed to be 0.0078 (n = 5). Using the optimum parameters, a diagnostic test was performed by the direct assay of SA in non-treated human blood and patient sera. Here, the developed results can be used for the direct assay of non-treated blood sera, organ monitoring, in-vivo diagnosis, and other assays requiring SA detection.