Marcela De Oliveira Carniello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcela De Oliveira Carniello has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Helaine Maria Besteti Pires
Universidade Estadual de Campinas
1 shared publication- João Renato Bennini Junior
Department of Obstetrics and Gynecology The State University of Campinas Campinas SP Brazil
1 shared publication - Luis Otávio Sarian
Department of Gynecology and Obstetrics, Fetal Medicine Program State University of Campinas Campinas Brazil
1 shared publication - Luiz Gustavo Oliveira Brito
Universidade Estadual de Campinas, Brazil
1 shared publication
Latest Publications
- 18 January 2022
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 59 (4) , 428-436
Diagnosis of placenta accreta spectrum in high‐risk women using ultrasonography or magnetic resonance imaging: systematic review and meta‐analysis
Objectives: To perform a systematic review and meta‐analysis of the diagnostic test accuracy of ultrasound and magnetic resonance imaging (MRI) and compare the performance of the two modalities in the diagnosis of placenta accreta spectrum (PAS).Methods: This was a systematic review conducted following the Cochrane Diagnostic Test Accuracy Reviews guideline. A literature search was performed in five databases: PubMed, EMBASE, PMC, The Cochrane Library and BVS‐Bireme between 27 July and 4 August 2020. The search was updated on 18 August 2021. We included observational studies evaluating diagnostic accuracy in women with risk factors for PAS who had undergone both ultrasound and MRI examinations, published in English between 2011 and 2021. Quality Assessment of Diagnostic Accuracy Studies‐2 was used to evaluate the quality of the studies. Forest plots for sensitivity and specificity with 95% CIs and receiver‐operating‐characteristics curves for ultrasound and MRI were constructed.Results: The literature search identified 266 studies. After reviewing the titles and abstracts of the articles, 51 were selected for full‐text review and 17 studies including 1301 women with MRI and ultrasound data available were selected for the meta‐analysis. The study population included 457 cases with PAS diagnosed using the gold standard method (intraoperative or histopathological analysis). The overall quality of the evaluated studies was considered satisfactory according to QUADAS‐2. The meta‐analysis revealed a sensitivity of 0.833 (95% CI, 0.776–0.878) and specificity of 0.834 (95% CI, 0.746–0.897) for ultrasound. For MRI, sensitivity was 0.838 (95% CI, 0.786–0.879) and specificity was 0.831 (95% CI, 0.770–0.878). There was no statistically significant difference between the two modalities. The Cochran's Q values indicated a high level of heterogeneity of sensitivity and specificity of ultrasound and MRI across studies.Conclusions: Ultrasound and MRI have similar accuracy in the diagnosis of PAS. These results suggest that, in a setting with a high prevalence of risk factors, the choice of imaging modality for initial screening for PAS should depend on the availability of equipment and the examiner's expertise. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
- 18 January 2022
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 59 (4) , 428-436
Diagnosis of placenta accreta spectrum in high‐risk women using ultrasonography or magnetic resonance imaging: systematic review and meta‐analysis
Objectives: To perform a systematic review and meta‐analysis of the diagnostic test accuracy of ultrasound and magnetic resonance imaging (MRI) and compare the performance of the two modalities in the diagnosis of placenta accreta spectrum (PAS).Methods: This was a systematic review conducted following the Cochrane Diagnostic Test Accuracy Reviews guideline. A literature search was performed in five databases: PubMed, EMBASE, PMC, The Cochrane Library and BVS‐Bireme between 27 July and 4 August 2020. The search was updated on 18 August 2021. We included observational studies evaluating diagnostic accuracy in women with risk factors for PAS who had undergone both ultrasound and MRI examinations, published in English between 2011 and 2021. Quality Assessment of Diagnostic Accuracy Studies‐2 was used to evaluate the quality of the studies. Forest plots for sensitivity and specificity with 95% CIs and receiver‐operating‐characteristics curves for ultrasound and MRI were constructed.Results: The literature search identified 266 studies. After reviewing the titles and abstracts of the articles, 51 were selected for full‐text review and 17 studies including 1301 women with MRI and ultrasound data available were selected for the meta‐analysis. The study population included 457 cases with PAS diagnosed using the gold standard method (intraoperative or histopathological analysis). The overall quality of the evaluated studies was considered satisfactory according to QUADAS‐2. The meta‐analysis revealed a sensitivity of 0.833 (95% CI, 0.776–0.878) and specificity of 0.834 (95% CI, 0.746–0.897) for ultrasound. For MRI, sensitivity was 0.838 (95% CI, 0.786–0.879) and specificity was 0.831 (95% CI, 0.770–0.878). There was no statistically significant difference between the two modalities. The Cochran's Q values indicated a high level of heterogeneity of sensitivity and specificity of ultrasound and MRI across studies.Conclusions: Ultrasound and MRI have similar accuracy in the diagnosis of PAS. These results suggest that, in a setting with a high prevalence of risk factors, the choice of imaging modality for initial screening for PAS should depend on the availability of equipment and the examiner's expertise. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 20 November 2015
- Published by PIBIC Unicamp in XXV Congresso de Iniciação Científica da Unicamp
- Vol. 1 Ano 2015 (Vol 1 Ano ) , 37586
Evaluation of pregnant women with rheumatic valve disease: maternal and perinatal outcomes
Pregnancy linked to heart disease is one of the first non-obstetric causes of maternal death and affects between 1 and 3% of pregnancies in Western countries. So far, there are few published data on the course of pregnancy in women affected by rheumatic valve disease, requiring the study of... Evento destinado a todos os alunos de graduação da UNICAMP que desenvolvem projetos de Iniciação Científica, com financiamento de alguma agência de fomento ou de maneira voluntária.
- 20 November 2015
- Published by PIBIC Unicamp in XXV Congresso de Iniciação Científica da Unicamp
- Vol. 1 Ano 2015 (Vol 1 Ano ) , 37586
Open AccessEvaluation of pregnant women with rheumatic valve disease: maternal and perinatal outcomes
Pregnancy linked to heart disease is one of the first non-obstetric causes of maternal death and affects between 1 and 3% of pregnancies in Western countries. So far, there are few published data on the course of pregnancy in women affected by rheumatic valve disease, requiring the study of... Evento destinado a todos os alunos de graduação da UNICAMP que desenvolvem projetos de Iniciação Científica, com financiamento de alguma agência de fomento ou de maneira voluntária.