Yeqiang Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yeqiang Deng has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Yu Wang
School of Electrical Engineering Wuhan University Wuhan China
16 shared publications Lei Lan
School of Electrical Engineering Wuhan University Wuhan China
10 shared publications- Xishan Wen
Department of Electrical Engineering and Automation, Wuhan University, Wuhan, China
6 shared publications Chaoying Fang
State Grid Fujian Electric Power Company Limited Research Institute, Fuzhou, China
4 shared publications- Haochen Zhang
Wuhan University
4 shared publications Yu Wang
School of Electrical and Automation Wuhan University Wuhan China
4 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc‐extinguishing characteristics of their chambers require further investigation. This study employed simulation and experimental methods to analyze the process through which devices with a semi‐closed short‐gap structure extinguish alternating‐current (AC) power frequency (50 Hz) arcs. First, a numerical model of AC arcs was established on the basis of magnetohydrodynamics theory using COMSOL Multiphysics software. This model was then used to simulate the dynamic arc plasma velocity, pressure and temperature within the extinguishing chamber of a device with a semi‐closed short‐gap structure. Subsequently, an experimental platform was constructed to conduct experiments involving extinguishing various magnitudes of continuous AC arcs in a fabricated semi‐closed short‐gap structure. The experimental and simulation results agreed with each other, demonstrating the effectiveness of the developed model. These results indicate that as the magnitude of an AC arc increases, the arc extinction time increases but remains within the time corresponding to half a cycle of the AC waveform.
- 7 August 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Open AccessStudy on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc‐extinguishing characteristics of their chambers require further investigation. This study employed simulation and experimental methods to analyze the process through which devices with a semi‐closed short‐gap structure extinguish alternating‐current (AC) power frequency (50 Hz) arcs. First, a numerical model of AC arcs was established on the basis of magnetohydrodynamics theory using COMSOL Multiphysics software. This model was then used to simulate the dynamic arc plasma velocity, pressure and temperature within the extinguishing chamber of a device with a semi‐closed short‐gap structure. Subsequently, an experimental platform was constructed to conduct experiments involving extinguishing various magnitudes of continuous AC arcs in a fabricated semi‐closed short‐gap structure. The experimental and simulation results agreed with each other, demonstrating the effectiveness of the developed model. These results indicate that as the magnitude of an AC arc increases, the arc extinction time increases but remains within the time corresponding to half a cycle of the AC waveform.
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Initial characteristics of positive streamer discharge under impulse voltage in high-speed airflow
The streamer discharge is the earliest discharge stage under impulse voltage and usually carried out in stationary air in the previous studies. However, the breakdown discharge characteristics of high-speed moving objects or those exposed to strong winds differ from those of traditional stationary targets, and the streamer discharge is important for subsequent discharge process. Therefore, it is significant to study the effect of air flow on the initial characteristics of streamer discharges. In this study, positive streamers under impulse voltage were investigated using a 2.5 mm diameter rod electrode in a wind tunnel, with a maximum airflow speed of 100 m/s. The tests were carried out in a darkroom, where discharge voltage and current were measured, and streamer morphology was captured. The experimental results indicate that regardless of the airflow speed, the initiation time and initiation voltage of the streamer decreases with increasing voltage rise rate. As the airflow speed increases, the initiation time of the streamer also decreases, accompanied by a reduction in dispersion. The streamer initiation voltage follows a similar trend to the initiation time, but with less consistency. From the discharge images, the streamer stem and its branches form a conical distribution, and increasing airflow causes the streamer stem to shorten and narrow. The injected charge of the streamer depends quadratically on the inception voltage; while the airflow alters the operating point along this relationship, the functional form of the dependence remains unchanged. Finally, the concept of critical volume was used to explain the experimental results.
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Initial characteristics of positive streamer discharge under impulse voltage in high-speed airflow
The streamer discharge is the earliest discharge stage under impulse voltage and usually carried out in stationary air in the previous studies. However, the breakdown discharge characteristics of high-speed moving objects or those exposed to strong winds differ from those of traditional stationary targets, and the streamer discharge is important for subsequent discharge process. Therefore, it is significant to study the effect of air flow on the initial characteristics of streamer discharges. In this study, positive streamers under impulse voltage were investigated using a 2.5 mm diameter rod electrode in a wind tunnel, with a maximum airflow speed of 100 m/s. The tests were carried out in a darkroom, where discharge voltage and current were measured, and streamer morphology was captured. The experimental results indicate that regardless of the airflow speed, the initiation time and initiation voltage of the streamer decreases with increasing voltage rise rate. As the airflow speed increases, the initiation time of the streamer also decreases, accompanied by a reduction in dispersion. The streamer initiation voltage follows a similar trend to the initiation time, but with less consistency. From the discharge images, the streamer stem and its branches form a conical distribution, and increasing airflow causes the streamer stem to shorten and narrow. The injected charge of the streamer depends quadratically on the inception voltage; while the airflow alters the operating point along this relationship, the functional form of the dependence remains unchanged. Finally, the concept of critical volume was used to explain the experimental results.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-8
SHAP-Based Interpretable Neural Network Framework for Lightning Risk Analysis and Diagnosis in Power Transmission Lines
Although SHAP and other explainable artificial intelligence (XAI) techniques have been applied in several power system scenarios, lightning protection strategies in transmission lines still rely heavily on the practical experience of operation and maintenance personnel. To address this gap, this study proposes a quantitative diagnostic framework based on SHapley Additive exPlanations (SHAP) to identify the root causes of high lightning risks. To facilitate the extensive computations required by SHAP, a dual-hidden-layer neural network is integrated as a surrogate model to efficiently approximate lightning trip rates. This framework is then applied to analyze the specific risk factors of transmission towers along a line in Yunnan Province, China. The results obtained using the SHAP method were also used to formulate targeted lightning protection measures for these towers, thereby effectively reducing their risks to a reasonable level. The quantitative weights derived using the SHAP method aligned well with theoretical principles of lightning trip rate calculations, validating the rationality and effectiveness of this method in diagnosing causes of lightning risks for transmission lines.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-8
SHAP-Based Interpretable Neural Network Framework for Lightning Risk Analysis and Diagnosis in Power Transmission Lines
Although SHAP and other explainable artificial intelligence (XAI) techniques have been applied in several power system scenarios, lightning protection strategies in transmission lines still rely heavily on the practical experience of operation and maintenance personnel. To address this gap, this study proposes a quantitative diagnostic framework based on SHapley Additive exPlanations (SHAP) to identify the root causes of high lightning risks. To facilitate the extensive computations required by SHAP, a dual-hidden-layer neural network is integrated as a surrogate model to efficiently approximate lightning trip rates. This framework is then applied to analyze the specific risk factors of transmission towers along a line in Yunnan Province, China. The results obtained using the SHAP method were also used to formulate targeted lightning protection measures for these towers, thereby effectively reducing their risks to a reasonable level. The quantitative weights derived using the SHAP method aligned well with theoretical principles of lightning trip rate calculations, validating the rationality and effectiveness of this method in diagnosing causes of lightning risks for transmission lines.
- Open Access
- 10 March 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Study of Positive Corona Discharge of Needle Plate Electrodes in Airflow
For high‐speed moving objects such as aircraft and wind turbine blades, discharge occurs under strong airflow. Research on lightning attachment characteristics has been extensive, whereas the role of corona discharge in pre‐breakdown streamer development has received less attention. This paper presents wind tunnel experiments on positive corona discharge in a needle‐to‐plate configuration under DC voltage, with airflow ranging from 0 to 50 m/s. The results show that airflow induces significant deviations in the streamer channel, with higher airflow velocities causing the corona to tilt further upwind. Additionally, airflow affects both the discharge intensity and the dispersion of space charge. This study reveals the displacement characteristics of streamer‐corona discharge and discusses the influence mechanism of airflow on space charge distribution.
- 10 March 2026
- Published by Institution of Engineering and Technology (IET) in High Voltage
Open AccessStudy of Positive Corona Discharge of Needle Plate Electrodes in Airflow
For high‐speed moving objects such as aircraft and wind turbine blades, discharge occurs under strong airflow. Research on lightning attachment characteristics has been extensive, whereas the role of corona discharge in pre‐breakdown streamer development has received less attention. This paper presents wind tunnel experiments on positive corona discharge in a needle‐to‐plate configuration under DC voltage, with airflow ranging from 0 to 50 m/s. The results show that airflow induces significant deviations in the streamer channel, with higher airflow velocities causing the corona to tilt further upwind. Additionally, airflow affects both the discharge intensity and the dispersion of space charge. This study reveals the displacement characteristics of streamer‐corona discharge and discusses the influence mechanism of airflow on space charge distribution.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Hydrophobicity Classification of Composite Insulators Using Multi-scale Water Droplet Detection and Feature Fusion
Hydrophobicity degradation is a critical factor leading to pollution flashovers in composite insulator systems. The International Electrotechnical Commission (IEC) 62073 visual inspection method suffers from ±1 level measurement uncertainty, while existing deep learning methods lack physical interpretability for maintenance decision-making. This paper presents a hierarchical framework employing a physically grounded intermediate representation. A five-level droplet taxonomy (C1-C5) based on contact angle physics decouples droplet morphology from surface assessment. An enhanced Faster Region-based Convolutional Neural Network (Faster R-CNN) with Squeeze-and-Excitation Residual Network-50 (SE-ResNet-50) backbone achieves 75.8% mean Average Precision on 16,535 labeled droplets. The fusion of 21 detection-derived and five image-processing features yields a 4.08% improvement over the naive combination. Evaluated on 1,160 independent images spanning four climate zones and 2-13 years of service life, the method achieves 77.09% Full Hit Accuracy (FHA, exact HC level match) and 99.13% Tolerant Accuracy (TA, predictions within ±1 level), compliant with IEC 62073 uncertainty tolerance. The hierarchical design enables verification of classification reasoning through inspectable C1-C5 intermediate outputs.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Hydrophobicity Classification of Composite Insulators Using Multi-scale Water Droplet Detection and Feature Fusion
Hydrophobicity degradation is a critical factor leading to pollution flashovers in composite insulator systems. The International Electrotechnical Commission (IEC) 62073 visual inspection method suffers from ±1 level measurement uncertainty, while existing deep learning methods lack physical interpretability for maintenance decision-making. This paper presents a hierarchical framework employing a physically grounded intermediate representation. A five-level droplet taxonomy (C1-C5) based on contact angle physics decouples droplet morphology from surface assessment. An enhanced Faster Region-based Convolutional Neural Network (Faster R-CNN) with Squeeze-and-Excitation Residual Network-50 (SE-ResNet-50) backbone achieves 75.8% mean Average Precision on 16,535 labeled droplets. The fusion of 21 detection-derived and five image-processing features yields a 4.08% improvement over the naive combination. Evaluated on 1,160 independent images spanning four climate zones and 2-13 years of service life, the method achieves 77.09% Full Hit Accuracy (FHA, exact HC level match) and 99.13% Tolerant Accuracy (TA, predictions within ±1 level), compliant with IEC 62073 uncertainty tolerance. The hierarchical design enables verification of classification reasoning through inspectable C1-C5 intermediate outputs.
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1143-1154
Numerical Simulation of Ion Flow Field and Multi-Factor Influence of Rotating Wind Turbine Tip Corona Discharge Under Thundercloud Electric Field
Rotating wind turbines are more vulnerable to lightning strikes than static wind turbine, possibly due to the different distribution of tip corona charges. However, there is a lack of research on the characteristics of blade tip corona charge distribution. This paper establishes a simulation model of corona charge distribution of rotating wind turbine. The long gap discharge test of the scaled wind turbine is carried out to verify the effectiveness of the simulation model. The simulation results show that the corona current increases with the increase of wind turbine speed, which is consistent with the test results. When the wind turbine rotates, the corona charge will migrate to the arc trajectory through which the blade rotates, which greatly reduces the charge density accumulated at the blade tip. Compared with the static state, the electric field intensity of the blade tip is higher when the wind turbine rotates, which will make it easier for the blade tip to initiate the upward leader. Moreover, the influence of different factors on the corona charge distribution of rotating wind turbine is calculated, and the function relationship between the maximum electric field intensity of the wind turbine tip and the rotation speed is established.
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1143-1154
Numerical Simulation of Ion Flow Field and Multi-Factor Influence of Rotating Wind Turbine Tip Corona Discharge Under Thundercloud Electric Field
Rotating wind turbines are more vulnerable to lightning strikes than static wind turbine, possibly due to the different distribution of tip corona charges. However, there is a lack of research on the characteristics of blade tip corona charge distribution. This paper establishes a simulation model of corona charge distribution of rotating wind turbine. The long gap discharge test of the scaled wind turbine is carried out to verify the effectiveness of the simulation model. The simulation results show that the corona current increases with the increase of wind turbine speed, which is consistent with the test results. When the wind turbine rotates, the corona charge will migrate to the arc trajectory through which the blade rotates, which greatly reduces the charge density accumulated at the blade tip. Compared with the static state, the electric field intensity of the blade tip is higher when the wind turbine rotates, which will make it easier for the blade tip to initiate the upward leader. Moreover, the influence of different factors on the corona charge distribution of rotating wind turbine is calculated, and the function relationship between the maximum electric field intensity of the wind turbine tip and the rotation speed is established.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 20 (1)
Lightning Risk Assessment for Multiple Wind Turbines Considering Real Terrain Effects
This study proposes a three‐dimensional lightning shielding assessment method for wind turbine clusters that considers lightning striking distance, terrain variation, and mutual shielding among turbines. Lightning striking distance formulas were derived for rotating and stationary wind turbines, and DEM data were introduced to represent real terrain. For a mean lightning current amplitude of −27.6 kA, the calculated striking distance of a rotating wind turbine was 275 m, close to the observed value of 276 m. The results show that mutual shielding becomes significant when turbine spacing is less than about 1000 m, and turbines at higher elevations provide stronger shielding for nearby lower elevation turbines. Validation using wind farms in Guangdong and Fujian showed that the simulated lightning risk trends were consistent with observations. This study provides significant insights for wind turbine layout, site selection, and lightning protection strategies.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 20 (1)
Open AccessLightning Risk Assessment for Multiple Wind Turbines Considering Real Terrain Effects
This study proposes a three‐dimensional lightning shielding assessment method for wind turbine clusters that considers lightning striking distance, terrain variation, and mutual shielding among turbines. Lightning striking distance formulas were derived for rotating and stationary wind turbines, and DEM data were introduced to represent real terrain. For a mean lightning current amplitude of −27.6 kA, the calculated striking distance of a rotating wind turbine was 275 m, close to the observed value of 276 m. The results show that mutual shielding becomes significant when turbine spacing is less than about 1000 m, and turbines at higher elevations provide stronger shielding for nearby lower elevation turbines. Validation using wind farms in Guangdong and Fujian showed that the simulated lightning risk trends were consistent with observations. This study provides significant insights for wind turbine layout, site selection, and lightning protection strategies.
- 1 October 2025
- Published by Springer Nature
- p. 239-249
Early Warning of Lightning Activity Based on Lightning Location Data and Meteorological Data
- 1 October 2025
- Published by Springer Nature
- p. 239-249
Early Warning of Lightning Activity Based on Lightning Location Data and Meteorological Data
- 1 October 2025
- Published by Springer Nature
- p. 199-215
Simulation Analysis of the Influence of Corona Charge on Wind Turbine’s Lightning Shielding Characteristics Under High-Speed Airflow
- 1 October 2025
- Published by Springer Nature
- p. 199-215
Simulation Analysis of the Influence of Corona Charge on Wind Turbine’s Lightning Shielding Characteristics Under High-Speed Airflow
- 25 February 2025
- Published by Springer Nature
- p. 248-256
Calculation and Analysis of Lightning Shielding Effect During Multiple Transmission Lines
- 25 February 2025
- Published by Springer Nature
- p. 248-256
Calculation and Analysis of Lightning Shielding Effect During Multiple Transmission Lines