CLCecilia Liang

Cecilia Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cecilia Liang has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Ferdinand Seith

    Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, 72076 Tuebingen, Germany

    5 shared publications
  • Brigitte Gückel

    University Tübingen Department of Radiology: Universitatsklinikum Tubingen Department fur Radiologie

    4 shared publications
  • Konstantin Nikolaou

    Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany

    4 shared publications
  • Petros Martirosian

    Universitätsklinikum Tübingen Department für Radiologie: Universitatsklinikum Tubingen Department fur Radiologie

    4 shared publications
  • Bernd Kühn

    Siemens Healthineers: Siemens Healthcare AG

    3 shared publications
  • Ferdinand Seith

    Universitätsklinikum Tübingen Department für Radiologie: Universitatsklinikum Tubingen Department fur Radiologie

    3 shared publications

Latest Publications

  • Open Access

    Investigating renal tissue responses to radiopharmaceutical therapy using multiparametric MRI

    by Cecilia Liang, Isabelle Loster, Maryanna Chaika, Aya Ghoul, Brigitte Gückel, Thomas Küstner, Bernd Kühn, Fritz Schick, Nils Trautwein, Christian La Fougére, et al.

    Objectives Renal toxicity is a recognized potential adverse effect of radiopharmaceutical therapy (RPT). While 177 Lu-based therapies are generally well tolerated, subtle therapy-related renal changes remain insufficiently characterized. This study investigated longitudinal renal alterations during 177 Lu-based RPT using multiparametric magnetic resonance imaging (mpMRI) and evaluated its potential for renal monitoring. Methods Twenty-three patients undergoing RPT with either [ 177 Lu]Lu-DOTATATE (n = 14) or [ 177 Lu]Lu-PSMA (n = 9) underwent renal mpMRI examinations before and during therapy with up to four treatment cycles. Imaging included arterial spin labeling, diffusion-weighted imaging with intravoxel incoherent motion analysis, blood oxygenation level-dependent imaging, T1 mapping, and volumetry. Renal scintigraphy, estimated glomerular filtration rate (eGFR), and absorbed renal radiation dose were assessed longitudinally. Results No significant decline in eGFR was observed during RPT after exclusion of two patients who developed urinary tract obstruction (p = 0.19). Longitudinal analysis revealed significant temporal changes in T1 values (p = 0.008) and perfusion fraction of IVIM (p = 0.005), as well as a modest decrease in the corticomedullary BOLD ratio (p = 0.020). No significant longitudinal changes were detected for other MRI or scintigraphic parameters. Absorbed renal radiation dose was not associated with changes in MRI-derived biomarkers, eGFR, or renal scintigraphy (all p > 0.05). Patients with urinary obstruction demonstrated distinct MRI abnormalities, including reduced renal blood flow (RBF) and altered BOLD metrics. Conclusions No clinically relevant renal functional deterioration or major imaging abnormalities were detected during contemporary 177 Lu-based RPT. Subtle longitudinal T1 increases may reflect mild structural tissue remodeling without measurable functional consequences. Renal mpMRI is feasible for non-invasive monitoring and may provide complementary information beyond conventional renal function assessment. Trial registration, DRKS, DRKS00018966, registered 10 October 2019; https://www.drks.de/search/de/results

  • Röntgendiagnostik: Einstelltechniken bei Standardaufnahmen der großen Gelenke

    by Chen Liang, Gabriel Lennart Keller, Cecilia Liang, Sandra Frantz

  • Open Access

    Automated Coregistered Segmentation for Volumetric Analysis of Multiparametric Renal MRI

    by Aya Ghoul, Cecilia Liang, Isabelle Loster, Lavanya Umapathy, Bernd Kühn, Petros Martirosian, Ferdinand Seith, Sergios Gatidis, Thomas Küstner

    Purpose: This study aims to develop and evaluate a fully automated deep learning‐driven postprocessing pipeline for multiparametric renal MRI, enabling accurate kidney alignment, segmentation, and quantitative feature extraction within a single efficient workflow. Methods: Our method has three main stages. First, a segmentation network delineates renal structures in high‐contrast images. Next, a deep learning‐based pairwise image registration algorithm maps the multiparametric image series to a common target and transfers the predicted annotations between the multiparametric images. Finally, clinically relevant quantitative parameters are extracted through region‐specific assessment of renal structure and function based on the aligned and segmented multiparametric data. We used five‐fold cross‐validation to compare the segmentation outcomes and extracted features with manual analyses in 24 patients with prostate cancer or neuroendocrine tumors and 10 healthy subjects, each undergoing repeated scans. Results: Our automated pipeline achieved high agreement with expert kidney segmentation while delivering significant alignment improvements through registration. Volumetric analysis showed a strong correlation ( r 0.9) with manual results, and feature extraction demonstrated high intraclass correlation coefficients with minimal bias. The complete processing pipeline, encompassing coregistration, segmentation, and feature extraction, required approximately 15 s per scan from raw input to final quantitative output. Conclusion: The study establishes a reliable automated pipeline for renal multiparametric MRI postprocessing. The achieved accuracy and efficiency can support improved diagnosis and treatment planning for patients with kidney disease.


  • Arterial Spin Labeling MRI for Noninvasive Monitoring of Treatment Response in Acute Pulmonary Embolism

    by Cecilia Liang, Max Munz, Petros Martirosian, Yasmin Komma, Brigitte Gückel, Rolf Pohmann, Jessica Henes, Konstantin Nikolaou, Meinrad Gawaz, Dominik Rath, et al.

    Arterial spin labeling MRI detected substantial improvement in lung perfusion after treatment and identified residual perfusion defects associated with persistent dyspnea in participants with pulmonary embolism.

  • Multiparametric functional MRI of the kidneys – evaluation of test-retest repeatability and effects of different manual and automatic image analysis strategies

    by Cecilia Liang, Isabelle Loster, Stephan Ursprung, Aya Ghoul, Thomas Küstner, Brigitte Gückel, Bernd Kühn, Fritz Schick, Petros Martirosian, Ferdinand Seith

    Multiparametric MRI is a promising technique for noninvasive structural and functional imaging of the kidneys that is gaining increasing importance in clinical research. Still, there are no standardized recommendations for analyzing the acquired images and there is a need to further evaluate the accuracy and repeatability of currently recommended MRI parameters. The aim of the study was to evaluate the test-retest repeatability of functional renal MRI parameters using different image analysis strategies.Ten healthy volunteers were examined twice with a multiparametric renal MRI protocol including arterial spin labeling (ASL), diffusion-weighted imaging (DWI) with intravoxel incoherent motion (IVIM), blood-oxygen-dependent (BOLD) imaging, T1 and T2 mapping, and volumetry with an interval of one week. The quantitative results of both kidneys were determined by manual organ segmentation, ROI analysis, and automatic segmentation based on the nnUNet framework. Test-retest repeatability of each parameter was computed using the within-subject coefficient of variance (wCV) and the intraclass coefficient (ICC). Segmentation accuracy and inter-reader agreement were evaluated using the dice score.Structural tissue parameters (T1, T2) showed wCV (%) between 4 and 11 and an ICC between 0.2 and 0.8. Functional parameters (ASL, BOLD and DWI) showed wCV (%) between 3 and 38 and an ICC between 0.0 and 0.7. The highest variances between test-retest scans were observed in perfusion measurements with ASL and IVIM (wCV: 17–37%). Quantitative analysis of the cortex and medulla showed a better repeatability when acquired using manual segmentation compared to ROI-based image analysis. Comparable repeatability was achieved with manual and automatic segmentation of the total kidney.Reasonable repeatability was achieved for all MR parameters. Structural MR parameters showed better repeatability compared to functional parameters. ROI-based image analysis showed overall lower repeatability compared to manual segmentation. Comparable repeatability to manual segmentation as well as acceptable segmentation accuracy could be achieved with automatic segmentation.


  • Open Access

    How [18F]-FDG-PET/CT Affects Clinical Management of Patients with Germ Cell Tumors in the Real World

    by Cecilia Liang, Julia Sekler, Brigitte Gückel, Christina Pfannenberg, Helmut Dittmann, Ferdinand Seith, Bastian Amend, Konstantin Nikolaou, Christian Philipp Reinert

    Objective: The aim of this study was to evaluate the impact of PET/CT on clinical management of patients with germ cell tumors (GCTs) conducted in a real-world setting, including avoidance of invasive procedures, additional diagnostic imaging, and changes in treatment. Methods: Patients with GCTs were prospectively enrolled into a PET/CT registry study between May 2013 and April 2021. Intended patient management prior and after PET/CT was documented using standardized questionnaires. Changes in oncologic staging and clinical management after PET/CT were recorded, including planned treatment and planned additional diagnostics. Results: Forty-three male patients with GCTs were included consecutively in this study. After PET/CT, oncologic staging changed in 22/43 patients (51%), with upstaging in seven cases (16%), downstaging in ten cases (23%), and cancer relapse in five cases (11%). The number of patients with intended curative treatment remained stable, while a considerable change in intended therapeutic intervention was noted after PET/CT, with an increase in planned chemotherapy from three to eleven patients and a decrease in planned surgical resection from eleven to two patients. In addition, PET/CT contributed to preventing patients from intended invasive procedures including biopsy and surgery in 8/43 (19%) cases and from additional diagnostic procedures in 25 (58%) cases. Conclusion: With the use of FDG-PET/CT as a tool to guide patient management in GCTs, we observed a notable impact on clinical staging and a consequent reduction in the need for additional invasive and diagnostic procedures. These findings are expected to be even more consequential in the future as treatment modalities improve and the life expectancy of GCT patients further increases. Key Points: PET/CT considerably influences the clinical stage of GCT patients. PET/CT has remarkable influence on the choice of therapeutic interventions and reduces additional diagnostic procedures.

  • Open Access

    Whole-Body Magnetic Resonance Imaging (MRI) for Staging Melanoma Patients in Direct Comparison to Computed Tomography (CT): Results from a Prospective Positron Emission Tomography (PET)/CT and PET/MRI Study

    by Christian Philipp Reinert, Cecilia Liang, Matthias Weissinger, Jonas Vogel, Andrea Forschner, Konstantin Nikolaou, Christian la Fougère, Ferdinand Seith

    Purpose: The consideration of radiation exposure is becoming more important in metastatic melanoma due to improved prognoses. The aim of this prospective study was to investigate the diagnostic performance of whole-body (WB) magnetic resonance imaging (MRI) in comparison to computed tomography (CT) with 18F-FDG positron emission tomography (PET)/CT and 18F-PET/MRI together with a follow-up as the reference standard. Methods: Between April 2014 and April 2018, a total of 57 patients (25 females, mean age of 64 ± 12 years) underwent WB-PET/CT and WB-PET/MRI on the same day. The CT and MRI scans were independently evaluated by two radiologists who were blinded to the patients’ information. The reference standard was evaluated by two nuclear medicine specialists. The findings were categorized into different regions: lymph nodes/soft tissue (I), lungs (II), abdomen/pelvis (III), and bone (IV). A comparative analysis was conducted for all the documented findings. Inter-reader reliability was assessed using Bland–Altman procedures, and McNemar’s test was utilized to determine the differences between the readers and the methods. Results: Out of the 57 patients, 50 were diagnosed with metastases in two or more regions, with the majority being found in region I. The accuracies of CT and MRI did not show significant differences, except in region II where CT detected more metastases compared to MRI (0.90 vs. 0.68, p = 0.008). On the other hand, MRI had a higher detection rate in region IV compared to CT (0.89 vs. 0.61, p > 0.05). The level of agreement between the readers varied depending on the number of metastases and the specific region, with the highest agreement observed in region III and the lowest observed in region I. Conclusions: In patients with advanced melanoma, WB-MRI has the potential to serve as an alternative to CT with comparable diagnostic accuracy and confidence across most regions. The observed limited sensitivity for the detection of pulmonary lesions might be improved through dedicated lung imaging sequences.


  • Free-breathing Arterial Spin Labeling MRI for the Detection of Pulmonary Embolism

    by Ahmed E. Othman, Cecilia Liang, Yasmin Komma, Max Munz, Manuel Kolb, Dominik Rath, Brigitte Gückel, Rolf Pohmann, Konstantin Nikolaou, Martin Schwartz, et al.

    Background Arterial spin labeling (ASL) MRI can be used to assess organ perfusion but has yet to be implemented for perfusion evaluation of the lung. Purpose To evaluate pseudo-continuous ASL (PCASL) MRI for the detection of acute pulmonary embolism (PE) and its potential as an alternative to CT pulmonary angiography (CTPA). Materials and Methods Between November 2020 and November 2021, 97 patients (median age, 61 years; 48 women) with suspected PE were enrolled in this prospective study. PCASL MRI was performed within a 72-hour period following CTPA under free-breathing conditions and included three orthogonal planes. The pulmonary trunk was labeled during systole, and the image was acquired during diastole of the subsequent cardiac cycle. Additionally, multisection, coronal, balanced, steady-state free-precession imaging was carried out. Two radiologists blindly assessed overall image quality, artifacts, and diagnostic confidence (five-point Likert scale, 5 = best). Patients were categorized as positive or negative for PE, and a lobe-wise assessment in PCASL MRI and CTPA was conducted. Sensitivity and specificity were calculated on a patient level with the final clinical diagnosis serving as the reference standard. Interchangeability between MRI and CTPA was also tested with use of an individual equivalence index (IEI). Results PCASL MRI was performed successfully in all patients with high scores for image quality, artifact, and diagnostic confidence (κ ≥ .74). Of the 97 patients, 38 were positive for PE. PCASL MRI depicted PE correctly in 35 of 38 patients with three false-positive and three false-negative findings, resulting in a sensitivity of 35 of 38 patients (92% [95% CI: 79, 98]) and a specificity of 56 of 59 patients (95% [95% CI: 86, 99]). Interchangeability analysis revealed an IEI of 2.6% (95% CI: 1.2, 3.8). Conclusion Free-breathing pseudo-continuous arterial spin labeling MRI depicted abnormal lung perfusion caused by acute pulmonary embolism and may be useful as a contrast material-free alternative to CT pulmonary angiography for selected patients. German Clinical Trials Register no. DRKS00023599 © RSNA, 2023.


  • Open Access

    Functional MRI to quantify perfusion changes of a renal allograft after embolization of an arteriovenous fistula

    by Cecilia Liang, David J. Heister, Martina Guthoff, Gerd Grözinger, Petros Martirosian, Ferdinand Seith

    Acute allograft injury was observed in a 37-year-old woman within a few weeks after kidney transplantation. Neither renal ultrasound nor computerized tomography (CT) and magnetic resonance (MR) angiography revealed any anomaly. An MR protocol was then performed including arterial spin labeling and intravoxel incoherent motion diffusion weighted imaging. Both arterial spin labeling and the perfusion fraction in the diffusion weighted imaging showed decreased perfusion compared to reference values. The patient subsequently underwent angiography, where an arteriovenous fistula in the upper calix of the transplant kidney was detected and immediate embolization was performed. A second functional MR, performed one week later, demonstrated a 40% increase in organ perfusion. We conclude that functional MR with arterial spin labeling and intravoxel incoherent motion have the potential to provide complementary information of clinical value to conventional imaging for monitoring renal allografts.