AFAndreas Filippaios

Andreas Filippaios

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Filippaios has a total of 176 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Multiclass Arrhythmia Classification Using Multimodal Smartwatch Photoplethysmography Signals Collected in Real-Life Settings

    by Dong Han, Jihye Moon, Luís R. Mercado Díaz, Darren Chen, Devan Williams, Fahimeh Mohagheghian, Om Ghetia, Andrew G. Peitzsch, Youngsun Kong, Nishat Nishita, et al.

    Objective: Smartwatches with photoplethysmographic (PPG) sensors are ideal for early atrial fibrillation (AF) detection through continuous monitoring. However, prior deep learning was limited either to controlled environments, to minimize motion artifacts, or to short duration data collection. Additionally, premature atrial/ventricular contractions (PAC/PVC), which often confound AF detection algorithms, remains understudied due to limited datasets. Current state-of-the-art methods achieve only 75% sensitivity for PAC/PVC class on minimally motion artifact corrupted PPG data, despite showing 97% AF detection accuracy. Methods: We addressed the above limitations using data from the recently completed NIH-funded Pulsewatch clinical trial which collected over two weeks of smartwatch PPG data from 106 subjects. Our computationally efficient 1D bi-directional Gated Recurrent Unit deep learning model incorporated multi-modal inputs (1D PPG, accelerometer, and heart rate data) to classify normal sinus rhythm, AF, and PAC/PVC. Results: Our model achieved an unprecedented 83% sensitivity for PAC/PVC detection while maintaining a high accuracy of 97.31% for AF detection, outperforming the best retrained state-of-the-art model by 20.81% and 2.55%, respectively. It was also 14 times more computationally efficient and 2.7 times faster. Testing on two external PPG datasets collected with a different smartwatch and a fingertip PPG sensor, our model demonstrated better generalizability with macro-averaged AUROC values of 96.22% and 94.17%, respectively. Conclusion: A light-weight multimodal input deep learning model can accurately distinguish PAC/PVC from AF, reducing false positive detection of AF. Significance: Accurate AF and PAC/PVC detection with minimal false positive detection can enhance clinical and public acceptance of smartwatch-based AF monitoring.


  • Open Access

    Patterns of adherence to home blood pressure monitoring among men and women in the Electronic Framingham Heart Study

    by Tenes J. Paul, Katherine Sadaniantz, Apurv Soni, Jean-Claude Asaker, Chathurangi H. Pathiravasan, Jordy Mehawej, Andreas Filippaios, Yuankai Zhang, Ziyue Wang, Chunyu Liu, et al.

    Worldwide, there are differences in hypertension control by sex. The use of home blood pressure monitoring (HBPM) is associated with lower average blood pressures and higher medication adherence. However, little is known about adherence trajectories and sex differences in HBPM. This study characterizes adherence to HBPM among those with and without hypertension. Electronic Framingham Heart Study participants were instructed to perform HBPM weekly for 1 year. Adherence was defined as having ≥1 measurement per week averaged over 4-week segments. Primary exposures of hypertension status and sex were self-reported. Group-based trajectory modeling was used to identify adherence trajectories. Logistic regression was applied to investigate factors associated with membership in each trajectory group in the sex-stratified and whole cohorts. Among 990 participants (58% women, age 53 ± 9 years, 26% hypertension), three groups with distinct HBPM adherence patterns were identified: “early discontinuation”, “gradual decrease”, and “high adherence”. Participants with hypertension were more likely to maintain “high adherence” compared to those without (OR 1.55; 95% CI 1.08–2.23), with similar findings seen among women with hypertension (OR 2.24; 95% CI 1.35–3.72) but not men. In women, these findings remained significant when adjusting for anxiety, depression, and blood pressure, but were attenuated by adjusting for age and income. This study highlights HBPM adherence trajectories and shows that women with hypertension were more likely to be in the high adherence group, though these associations were attenuated after adjusting for demographic factors and co-morbidities. Future studies should explore strategies to enhance adherence in populations at risk of early discontinuation.


  • Open Access

    Patterns of Adherence to Home Blood Pressure Monitoring Among Men and Women in the Electronic Framingham Heart Study

    by Tenes J. Paul, Katherine Sadaniantz, Apurv Soni, Jean-Claude Asaker, Chathurangi H. Pathiravasan, Jordy Mehawej, Andreas Filippaios, Yuankai Zhang, Ziyue Wang, Chunyu Liu, et al.

    Background Worldwide, there are differences in hypertension control by sex. The use of home blood pressure monitoring (HBPM) is associated with lower average blood pressures and higher medication adherence. However, little is known about adherence trajectories and sex differences in HBPM. This study characterizes adherence to HBPM among those with and without hypertension. Methods Electronic Framingham Heart Study participants were instructed to perform HBPM weekly for 1 year. Adherence was defined as having ≥1 measurement per week averaged over 4-week segments. Primary exposures of hypertension status and sex were self-reported. Group-based trajectory modeling was used to identify adherence trajectories. Logistic regression was applied to investigate factors associated with membership in each trajectory group in the sex-stratified and whole cohorts. Results Among 990 participants (58% women, age 53±9 years, 26% hypertension), three groups with distinct HBPM adherence patterns were identified: “early discontinuation”, “gradual decrease”, and “high adherence”. Participants with hypertension were more likely to maintain “high adherence” compared to those without (OR 1.55; 95% CI 1.08-2.23), with similar findings seen among women with hypertension (OR 2.24; 95% CI 1.35-3.72) but not men. In women, these findings remained significant when adjusting for anxiety, depression, and blood pressure, but were attenuated by adjusting for age and income. Conclusions This study highlights HBPM adherence trajectories and shows that women with hypertension were more likely to be in the high adherence group, though these associations were attenuated after adjusting for demographic factors and co-morbidities. Future studies should explore strategies to enhance adherence in populations at risk of early discontinuation.

  • Open Access

    Multiclass arrhythmia classification using multimodal smartwatch photoplethysmography signals collected in real-life settings

    by Dong Han, Jihye Moon, Luís Roberto Mercado Díaz, Darren Chen, Devan Williams, Fahimeh Mohagheghian, Om Ghetia, Andrew G. Peitzsch, Youngsun Kong, Nishat Nishita, et al.

    In the early stages of atrial fibrillation (AF), most cases are paroxysmal (pAF), making identification only possible with continuous and prolonged monitoring. With the advent of wearables, smartwatches equipped with photoplethysmographic (PPG) sensors are an ideal approach for continuous monitoring of pAF. There have been numerous studies demonstrating successful capture of pAF events, especially using deep learning. However, deep learning requires a large amount of data and independent testing on diverse datasets, to ensure the generalizability of the model, and most prior studies did not meet these requirements. Moreover, most prior studies using wearable-based PPG sensor data collection were limited either to controlled environments, to minimize motion artifacts, or to short duration data collection. Most importantly, frequent premature atrial and ventricular contractions (PAC/PVC) can confound most AF detection algorithms. This has not been well studied, largely due to limited datasets containing these rhythms. Note that the recent deep learning models show 97% AF detection accuracy, and the sensitivity of the current state-of-the-art technique for PAC/PVC detection is only 75% on minimally motion artifact corrupted PPG data. Our study aims to address the above limitations using a recently completed NIH-funded Pulsewatch clinical trial which collected smartwatch PPG data over two weeks from 106 subjects. For our approach, we used multi-modal data which included 1D PPG, accelerometer, and heart rate data. We used a computationally efficient 1D bi-directional Gated Recurrent Unit (1D-Bi-GRU) deep learning model to detect three classes: normal sinus rhythm, AF, and PAC/PVC. Our proposed 1D-Bi-GRU model’s performance was compared with two other deep learning models that have reported some of the highest performance metrics, in prior work. For three-arrhythmia-classification, testing data for all deep learning models consisted of using independent data and subjects from the training data, and further evaluations were performed using two independent datasets that were not part of the training dataset. Our multimodal model achieved an unprecedented 83% sensitivity for PAC/PVC detection while maintaining a high accuracy of 97.31% for AF detection. Our model was computationally more efficient (14 times more efficient and 2.7 times faster) and outperformed the best state-of-the-art model by 20.81% for PAC/PVC sensitivity and 2.55% for AF accuracy. We also tested our models on two independent PPG datasets collected with a different smartwatch and a fingertip PPG sensor. Our three-arrhythmia-classification results show high macro-averaged area under the receiver operating characteristic curve values of 96.22%, and 94.17% for two independent datasets, demonstrating better generalizability of the proposed model.


  • Open Access

    Accuracy, Usability, and Adherence of Smartwatches for Atrial Fibrillation Detection in Older Adults After Stroke: Randomized Controlled Trial

    by Eric Y Ding, Khanh-Van Tran, Darleen Lessard, Ziyue Wang, Dong Han, Fahimeh Mohagheghian, Edith Mensah Otabil, Kamran Noorishirazi, Jordy Mehawej, Andreas Filippaios, et al.

    Background: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. Objective: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. Methods: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. Results: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. Conclusions: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. Trial Registration: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394 International Registered Report Identifier (IRRID): RR2-10.1016/j.cvdhj.2021.07.002


  • Performance of Rapid Antigen Tests to Detect Symptomatic and Asymptomatic SARS-CoV-2 Infection

    by Apurv Soni, Carly Herbert, Honghuang Lin, Yi Yan, Caitlin Pretz, Pamela Stamegna, Biqi Wang, Taylor Orwig, Colton Wright, Seanan Tarrant, et al.

    The performance of rapid antigen tests (Ag-RDTs) for screening asymptomatic and symptomatic persons for SARS-CoV-2 is not well established. To evaluate the performance of Ag-RDTs for detection of SARS-CoV-2 among symptomatic and asymptomatic participants. This prospective cohort study enrolled participants between October 2021 and January 2022. Participants completed Ag-RDTs and reverse transcriptase polymerase chain reaction (RT-PCR) testing for SARS-CoV-2 every 48 hours for 15 days. Participants were enrolled digitally throughout the mainland United States. They self-collected anterior nasal swabs for Ag-RDTs and RT-PCR testing. Nasal swabs for RT-PCR were shipped to a central laboratory, whereas Ag-RDTs were done at home. Of 7361 participants in the study, 5353 who were asymptomatic and negative for SARS-CoV-2 on study day 1 were eligible. In total, 154 participants had at least 1 positive RT-PCR result. The sensitivity of Ag-RDTs was measured on the basis of testing once (same-day), twice (after 48 hours), and thrice (after a total of 96 hours). The analysis was repeated for different days past index PCR positivity (DPIPPs) to approximate real-world scenarios where testing initiation may not always coincide with DPIPP 0. Results were stratified by symptom status. Among 154 participants who tested positive for SARS-CoV-2, 97 were asymptomatic and 57 had symptoms at infection onset. Serial testing with Ag-RDTs twice 48 hours apart resulted in an aggregated sensitivity of 93.4% (95% CI, 90.4% to 95.9%) among symptomatic participants on DPIPPs 0 to 6. When singleton positive results were excluded, the aggregated sensitivity on DPIPPs 0 to 6 for 2-time serial testing among asymptomatic participants was lower at 62.7% (CI, 57.0% to 70.5%), but it improved to 79.0% (CI, 70.1% to 87.4%) with testing 3 times at 48-hour intervals. Participants tested every 48 hours; therefore, these data cannot support conclusions about serial testing intervals shorter than 48 hours. The performance of Ag-RDTs was optimized when asymptomatic participants tested 3 times at 48-hour intervals and when symptomatic participants tested 2 times separated by 48 hours. National Institutes of Health RADx Tech program.


  • Open Access

    Bilateral Ovarian Serous Borderline Tumor with Non-Invasive Endometrial Implants

    by Melissa Bou Malham, Jordy Mehawej, Andreas Filippaios, Christina Kushnir, Paulette Mhawech-Fauceglia

    Herein, we are presenting a case of a 33-year-old woman who presented to the emergency department complaining of persistent lower abdominal pain of one-day duration. Physical examination revealed abdominal tenderness with right lower quadrant rebound tenderness. Computed tomography abdomen/pelvis showed a 6 cm possible necrotic mass of the left ovary with moderate amount of complex ascites. A laparoscopic left oophorectomy with bilateral salpingectomy, right ovarian biopsy, and appendectomy were performed without complications. The cut surface of the left ovary showed a ovarian mass, and the cut surface revealed multiple gray-tan friable papillary excrescence. Microscopic evaluation showed findings consistent with left and right ovarian serous borderline tumor (SBT). Subsequently, a tumor staging was conducted with total laparoscopic hysterectomy, pelvic and periaortic lymph node dissection, and omentectomy. The endometrium sections showed several small foci of SBT within the endometrial stroma, consistent with non-invasive implants of the endometrium. The omentum and lymph nodes were all negative for malignancy. SBTs associated with endometrial implants are very rare with only one case reported in the literature. Their existence can cause diagnostic challenges, and they should be acknowledged for early diagnosis and to plan for patient’s treatment and outcome.


  • Open Access

    Design and implementation of a digital site-less clinical study of serial rapid antigen testing to identify asymptomatic SARS-CoV-2 infection

    by Apurv Soni, Carly Herbert, Caitlin Pretz, Pamela Stamegna, Andreas Filippaios, Qiming Shi, Thejas Suvarna, Emma Harman, Summer Schrader, Chris Nowak, et al.

    Rapid antigen detection tests (Ag-RDT) for SARS-CoV-2 with emergency use authorization generally include a condition of authorization to evaluate the test’s performance in asymptomatic individuals when used serially. We aim to describe a novel study design that was used to generate regulatory-quality data to evaluate the serial use of Ag-RDT in detecting SARS-CoV-2 virus among asymptomatic individuals. This prospective cohort study used a siteless, digital approach to assess longitudinal performance of Ag-RDT. Individuals over 2 years old from across the USA with no reported COVID-19 symptoms in the 14 days prior to study enrollment were eligible to enroll in this study. Participants throughout the mainland USA were enrolled through a digital platform between October 18, 2021 and February 15, 2022. Participants were asked to test using Ag-RDT and molecular comparators every 48 hours for 15 days. Enrollment demographics, geographic distribution, and SARS-CoV-2 infection rates are reported. A total of 7361 participants enrolled in the study, and 492 participants tested positive for SARS-CoV-2, including 154 who were asymptomatic and tested negative to start the study. This exceeded the initial enrollment goals of 60 positive participants. We enrolled participants from 44 US states, and geographic distribution of participants shifted in accordance with the changing COVID-19 prevalence nationwide. The digital site-less approach employed in the “Test Us At Home” study enabled rapid, efficient, and rigorous evaluation of rapid diagnostics for COVID-19 and can be adapted across research disciplines to optimize study enrollment and accessibility.


  • Open Access

    Anxiety, patient activation, and quality of life among stroke survivors prescribed smartwatches for atrial fibrillation monitoring

    by Tenes J. Paul, Khanh-Van Tran, Jordy Mehawej, Darleen Lessard, Eric Ding, Andreas Filippaios, Sakeina Howard-Wilson, Edith Mensah Otabil, Kamran Noorishirazi, Syed Naeem, et al.


  • Open Access

    Finding a Needle in a Haystack: Design and Implementation of a Digital Site-less Clinical Study of Serial Rapid Antigen Testing to Identify Asymptomatic SARS-CoV-2 Infection

    by Apurv Soni, Carly Herbert, Caitlin Pretz, Pamela Stamegna, Andreas Filippaios, Qiming Shi, Thejas Suvarna, Emma Harman, Summer Schrader, Chris Nowak, et al.

    Background Over-the-counter rapid antigen tests for SARS-CoV-2 with an Emergency Use Authorization (EUA) in the United States generally include a condition of authorization to evaluate the test’s performance in asymptomatic individuals when used serially. A goal of this study was to investigate the performance of SARS-CoV-2 antigen serial testing and generate data to support regulatory decisions. Objective To describe a novel study design to evaluate serial use of rapid antigen tests in detecting SARS-CoV-2 virus among asymptomatic individuals. Design Prospective cohort study using a decentralized approach. Eligible participants from across the U.S. could enroll and complete this study from their home environment through a study app. Participant enrollment was prioritized based on regional 7-day case rates, participants’ vaccination status, and sociodemographic characteristics prior to enrollment. Prioritization criteria were adjusted on a daily or weekly basis. Enrolled participants were mailed rapid antigen tests and molecular comparator collection kits and asked to test every 48 hours for 15 days. Three companies’ rapid antigen tests were used in the study; assignment of participant to a test was criteria-based and non-random, precluding head-to-head comparison between the tests. Participants Mainland United States residents over 2 years old with no reported COVID-19 symptoms in the 14 days prior to study enrollment. Main Measures Participant demographics, COVID-19 vaccination status, and geographic distribution were used to understand the impact of the site-less recruitment and enrollment strategy. Key Results A total of 7,361 participants enrolled in the study between October 18, 2021 and February 15, 2022. Throughout the study, 369 participants tested positive for SARS-CoV-2, including 167 who were asymptomatic and tested negative on SARS-CoV-2 molecular assays to start the study. This exceeded the initial enrollment goals of 60 positive participants. We enrolled participants from 44 of the 48 mainland U.S. states, and geographic distribution of participants shifted in accordance with the changing COVID-19 prevalence nationwide. Conclusions The novel, digital site-less approach employed in the ‘Test Us At Home’ study enabled rapid, efficient, and rigorous evaluation of rapid diagnostics for COVID-19, and can be adapted across research disciplines to optimize study enrollment and accessibility.