Edvaldo Vasconcelos Soares Maciel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edvaldo Vasconcelos Soares Maciel has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Mauro Lanças
Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O. Box 780, Sao Carlos 13566590, Brazil
8 shared publications - Frederik Lermyte
Department of Chemistry, Clemens-Schöpf-Institute of Chemistry and Biochemistry, Technical University of Darmstadt, Peter-Grünberg-Strasse 4, 64287 Darmstadt, Germany
5 shared publications - Alejandro Cifuentes
Laboratory of Foodomics, Institute of Food Science Research, CIAL, CSIC, Nicolás Cabrera 9, Madrid 28049, Spain
2 shared publications - Ana Lúcia de Toffoli
Institute of Chemistry of São Carlos, University of São Paulo, São Carlos, CEP 13566590, SP, Brazil
2 shared publications - Ana Maria Barbosa-Medina
São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
2 shared publications - Christian Meyners
Technical University Darmstadt
2 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Wiley in Mass Spectrometry Reviews
Keeping It Native: Non‐Denaturing Approaches to Top‐Down Protein Mass Spectrometry
Top‐down proteomics and top‐down mass spectrometry approaches provide direct characterization of proteoforms; the specific molecular forms of proteins, including post‐translational modifications, truncations, alternative splicing, and sequence variants. To date, most top‐down studies have been performed under denaturing conditions, losing critical information about protein folding and noncovalent protein‐protein and protein‐ligand interactions. However, recent efforts to apply non‐denaturing, or native, ionization to top‐down mass spectrometry and top‐down proteomics have shown substantial promise for characterizing these higher‐order and more transient interactions. This review covers progress over the last 35 years in non‐denaturing top‐down approaches and addresses the inherent strengths and challenges of the technique. We cover three major areas of applications: (1) Ligand binding and drug discovery, (2) Structural biology, and (3) Proteomics aspects and bioinformatics.
- 25 October 2026
- Published by Wiley in Mass Spectrometry Reviews
Open AccessKeeping It Native: Non‐Denaturing Approaches to Top‐Down Protein Mass Spectrometry
Top‐down proteomics and top‐down mass spectrometry approaches provide direct characterization of proteoforms; the specific molecular forms of proteins, including post‐translational modifications, truncations, alternative splicing, and sequence variants. To date, most top‐down studies have been performed under denaturing conditions, losing critical information about protein folding and noncovalent protein‐protein and protein‐ligand interactions. However, recent efforts to apply non‐denaturing, or native, ionization to top‐down mass spectrometry and top‐down proteomics have shown substantial promise for characterizing these higher‐order and more transient interactions. This review covers progress over the last 35 years in non‐denaturing top‐down approaches and addresses the inherent strengths and challenges of the technique. We cover three major areas of applications: (1) Ligand binding and drug discovery, (2) Structural biology, and (3) Proteomics aspects and bioinformatics.
- 27 May 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (13) , 2829-2836
Measuring the hydrodynamic radii of peptides and proteins with an unmodified LC-ESI-MS instrument operating in a Taylor dispersion regime
Native ion mobility – mass spectrometry has been well established in recent years as a structural biology method. However, it is still useful to combine gas-phase techniques with complementary solution-phase measurements, for example hydrodynamic radius (Rh) determination. A common method to measure protein Rh is the use of Taylor dispersion analysis (TDA), which relies on measuring the longitudinal dispersion of an analyte in a laminar flow within a capillary. This type of analysis most often relies on spectroscopic (e.g., fluorescence-based) detection, although a few studies have reported the use of custom-built or modified fluidics systems coupled with MS-based detection. Here, we have repurposed a standard, unmodified LC-MS system, operated without a column, to measure hydrodynamic radii of peptides and proteins, including noncovalent complexes, ranging from 300 Da to 133 kDa. The Rh values we measured showed excellent correlation with gas-phase collision cross-sections as well as Rh values measured with a conventional TDA instrument with fluorescence-based detection. Notably, due to the mass-selective readout of our method, which is based on analysis of extracted ion chromatograms, we were able to perform multiplexed Rh measurements of several proteins in a single experiment, and also measured apparent Rh values for different oligomeric states of BSA and concanavalin A. Consistent with prior literature, the latter data suggested that concanavalin A primarily exists as a dimer and tetramer in solution, with monomer signals being largely due to dissociation during electrospray ionisation. We have named our method Hydrodynamic Radii from an Unmodified Liquid Chromatography-Mass Spectrometer (HYDRAULIC-MS).
- 27 May 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (13) , 2829-2836
Measuring the hydrodynamic radii of peptides and proteins with an unmodified LC-ESI-MS instrument operating in a Taylor dispersion regime
Native ion mobility – mass spectrometry has been well established in recent years as a structural biology method. However, it is still useful to combine gas-phase techniques with complementary solution-phase measurements, for example hydrodynamic radius (Rh) determination. A common method to measure protein Rh is the use of Taylor dispersion analysis (TDA), which relies on measuring the longitudinal dispersion of an analyte in a laminar flow within a capillary. This type of analysis most often relies on spectroscopic (e.g., fluorescence-based) detection, although a few studies have reported the use of custom-built or modified fluidics systems coupled with MS-based detection. Here, we have repurposed a standard, unmodified LC-MS system, operated without a column, to measure hydrodynamic radii of peptides and proteins, including noncovalent complexes, ranging from 300 Da to 133 kDa. The Rh values we measured showed excellent correlation with gas-phase collision cross-sections as well as Rh values measured with a conventional TDA instrument with fluorescence-based detection. Notably, due to the mass-selective readout of our method, which is based on analysis of extracted ion chromatograms, we were able to perform multiplexed Rh measurements of several proteins in a single experiment, and also measured apparent Rh values for different oligomeric states of BSA and concanavalin A. Consistent with prior literature, the latter data suggested that concanavalin A primarily exists as a dimer and tetramer in solution, with monomer signals being largely due to dissociation during electrospray ionisation. We have named our method Hydrodynamic Radii from an Unmodified Liquid Chromatography-Mass Spectrometer (HYDRAULIC-MS).
- Open Access
- 1 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Discovery of fully synthetic FKBP12-mTOR molecular glues
Molecular glues are a class of drug modalities with the potential to engage otherwise undruggable targets. However, the rational discovery of molecular glues for desired targets is a major challenge and most known molecular glues have been discovered by serendipity. Here we present the first fully synthetic FKBP12-mTOR molecular glues, which were discovered from a FKBP-focused, target-unbiased ligand library. Our biochemical screening of >1000 in-house FKBP ligands yielded one hit that induced dimerization of FKBP12 and the FRB domain of mTOR. The crystal structure of the ternary complex revealed that the hit targeted a similar surface on FRB domain compared to natural product rapamycin but with a radically different interaction pattern. Structure-guided optimization improved potency 500-fold and led to compounds, which initiate FKBP12-FRB complex formation in cells. Our results show that molecular glues targeting flat surfaces can be discovered by focused screening and support the use of FKBP12 as a versatile presenter protein for molecular glues.
- 1 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDiscovery of fully synthetic FKBP12-mTOR molecular glues
Molecular glues are a class of drug modalities with the potential to engage otherwise undruggable targets. However, the rational discovery of molecular glues for desired targets is a major challenge and most known molecular glues have been discovered by serendipity. Here we present the first fully synthetic FKBP12-mTOR molecular glues, which were discovered from a FKBP-focused, target-unbiased ligand library. Our biochemical screening of >1000 in-house FKBP ligands yielded one hit that induced dimerization of FKBP12 and the FRB domain of mTOR. The crystal structure of the ternary complex revealed that the hit targeted a similar surface on FRB domain compared to natural product rapamycin but with a radically different interaction pattern. Structure-guided optimization improved potency 500-fold and led to compounds, which initiate FKBP12-FRB complex formation in cells. Our results show that molecular glues targeting flat surfaces can be discovered by focused screening and support the use of FKBP12 as a versatile presenter protein for molecular glues.
- Open Access
- 21 July 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (14) , 11746
NanoLC-EI-MS: Perspectives in Biochemical Analysis
Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses. However, to fully utilize EI-MS for heavy and non-volatile molecules, a new technology that enables the coupling of liquid chromatography with EI-MS is needed. Recent advancements in nanoLC have addressed the compatibility issues between LC and EI-MS, and innovative interfacing strategies such as Direct-EI, liquid electron ionization (LEI), and Cold-EI have extended the application of EI-MS beyond the determination of volatile organic molecules. This review provides an overview of the latest developments in nanoLC-EI-MS interfacing technologies, discussing their scope and limitations. Additionally, selected examples of nanoLC-EI-MS applications in the field of biochemical analysis are presented, highlighting the potential prospects and benefits that the establishment of this technique can bring to this field.
- 21 July 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (14) , 11746
Open AccessNanoLC-EI-MS: Perspectives in Biochemical Analysis
Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses. However, to fully utilize EI-MS for heavy and non-volatile molecules, a new technology that enables the coupling of liquid chromatography with EI-MS is needed. Recent advancements in nanoLC have addressed the compatibility issues between LC and EI-MS, and innovative interfacing strategies such as Direct-EI, liquid electron ionization (LEI), and Cold-EI have extended the application of EI-MS beyond the determination of volatile organic molecules. This review provides an overview of the latest developments in nanoLC-EI-MS interfacing technologies, discussing their scope and limitations. Additionally, selected examples of nanoLC-EI-MS applications in the field of biochemical analysis are presented, highlighting the potential prospects and benefits that the establishment of this technique can bring to this field.
- Open Access
Applicability and Limitations of a Capillary-LC Column-Switching System Using Hybrid Graphene-Based Stationary Phases
Graphene oxide sheets fixed over silica particles (SiGO) and their modification functionalized with C18 and endcapped (SiGO-C18ec) have been reported as sorbents for extraction and analytical columns in LC. In this study, a SiGO column was selected as the extraction column and a SiGO-C18ec as the analytical column to study the applicability and limitations of a column-switching system composed exclusively of columns packed with graphene-based sorbents. Pyriproxyfen and abamectin B1a were selected as the analytes, and orange-flavored carbonated soft drinks as the matrix. The proposed system could be successfully applied to the pyriproxyfen analysis in a concentration range between 0.5 to 25 µg/mL presenting a linearity of R2 = 0.9931 and an intra-day and inter-day accuracy of 82.2–111.4% (RSD < 13.3%) and 95.5–99.8% (RSD < 12.7%), respectively. Furthermore, the matrix composition affected the area observed for the pyriproxyfen: the higher the concentration of orange juice in the soft drink, the higher the pyriproxyfen the signal observed. Additionally, the SiGO extraction column presented a life use of 120 injections for this matrix. In contrast, the proposed system could not apply to the analysis of abamectin B1a, and the SiGO-C18ec analytical column presented significant tailing compared to a similar approach with a C18 analytical column.
Open AccessApplicability and Limitations of a Capillary-LC Column-Switching System Using Hybrid Graphene-Based Stationary Phases
Graphene oxide sheets fixed over silica particles (SiGO) and their modification functionalized with C18 and endcapped (SiGO-C18ec) have been reported as sorbents for extraction and analytical columns in LC. In this study, a SiGO column was selected as the extraction column and a SiGO-C18ec as the analytical column to study the applicability and limitations of a column-switching system composed exclusively of columns packed with graphene-based sorbents. Pyriproxyfen and abamectin B1a were selected as the analytes, and orange-flavored carbonated soft drinks as the matrix. The proposed system could be successfully applied to the pyriproxyfen analysis in a concentration range between 0.5 to 25 µg/mL presenting a linearity of R2 = 0.9931 and an intra-day and inter-day accuracy of 82.2–111.4% (RSD < 13.3%) and 95.5–99.8% (RSD < 12.7%), respectively. Furthermore, the matrix composition affected the area observed for the pyriproxyfen: the higher the concentration of orange juice in the soft drink, the higher the pyriproxyfen the signal observed. Additionally, the SiGO extraction column presented a life use of 120 injections for this matrix. In contrast, the proposed system could not apply to the analysis of abamectin B1a, and the SiGO-C18ec analytical column presented significant tailing compared to a similar approach with a C18 analytical column.
- Open Access
- 24 April 2023
- Published by Wiley in Proteomics
- Vol. 24 (3-4) , e2300082
Charge site manipulation to enhance top‐down fragmentation efficiency
In recent years, top‐down mass spectrometry has become a widely used approach to study proteoforms; however, improving sequence coverage remains an important goal. Here, two different proteins, α‐synuclein and bovine carbonic anhydrase, were subjected to top‐down collision‐induced dissociation (CID) after electrospray ionisation. Two high‐boiling solvents, DMSO and propylene carbonate, were added to the protein solution in low concentration (2%) and the effects on the top‐down fragmentation patterns of the proteins were systematically investigated. Each sample was measured in triplicate, which revealed highly reproducible differences in the top‐down CID fragmentation patterns in the presence of a solution additive, even if the same precursor charge state was isolated in the quadrupole of the instrument. Further investigation supports the solution condition‐dependent selective formation of different protonation site isomers as the underlying cause of these differences. Higher sequence coverage was often observed in the presence of additives, and the benefits of this approach became even more evident when datasets from different solution conditions were combined, as increases up to 35% in cleavage coverage were obtained. Overall, this approach therefore represents a promising opportunity to increase top‐down fragmentation efficiency.
- 24 April 2023
- Published by Wiley in Proteomics
- Vol. 24 (3-4) , e2300082
Open AccessCharge site manipulation to enhance top‐down fragmentation efficiency
In recent years, top‐down mass spectrometry has become a widely used approach to study proteoforms; however, improving sequence coverage remains an important goal. Here, two different proteins, α‐synuclein and bovine carbonic anhydrase, were subjected to top‐down collision‐induced dissociation (CID) after electrospray ionisation. Two high‐boiling solvents, DMSO and propylene carbonate, were added to the protein solution in low concentration (2%) and the effects on the top‐down fragmentation patterns of the proteins were systematically investigated. Each sample was measured in triplicate, which revealed highly reproducible differences in the top‐down CID fragmentation patterns in the presence of a solution additive, even if the same precursor charge state was isolated in the quadrupole of the instrument. Further investigation supports the solution condition‐dependent selective formation of different protonation site isomers as the underlying cause of these differences. Higher sequence coverage was often observed in the presence of additives, and the benefits of this approach became even more evident when datasets from different solution conditions were combined, as increases up to 35% in cleavage coverage were obtained. Overall, this approach therefore represents a promising opportunity to increase top‐down fragmentation efficiency.
- Open Access
Online Extraction Followed by LC–MS/MS Analysis of Lipids in Natural Samples: A Proof-of-Concept Profiling Lecithin in Seeds
Sample preparation is usually a complex and time-consuming procedure, which can directly affect the quality of the analysis. Recent efforts have been made to establish analytical methods involving minimal sample preparation, automatized and performed online with the analytical techniques. Online Extraction coupled with Liquid Chromatography–Mass Spectrometry (OLE–LC–MS) allows a fully connected extraction, separation, and analysis system. In this work, the lecithin profile was investigated in commercial sunflower, almonds, peanuts, and pistachio seeds to demonstrate that the concept of extraction, followed by the online analysis of the extract, could be applied to analyze this class of analytes in such complex solid matrices without a prior off-line solvent extraction step. The extraction phase gradient method was optimized. Two different analytical columns were explored, one being a conventional C18 (50 × 2.1 mm, 1.7 µm SPP) and the other a novel self-packed SIGO-C18ec (100 × 0.5, 5 µm FPP), which resulted in better separation. The analysis repeatability was investigated, and suggestions to improve it were pointed out. A characteristic ion with a m/z of 184, related to lysophosphatidylcholine structure, was used to identify the lecithin compounds. The temperature effect on the chromatograms was also explored. In short, it was found that the OLE–LC–MS approach is suitable for the analysis of lecithin compounds in seeds, being a promising alternative for lipidomics approaches in the near future.
Open AccessOnline Extraction Followed by LC–MS/MS Analysis of Lipids in Natural Samples: A Proof-of-Concept Profiling Lecithin in Seeds
Sample preparation is usually a complex and time-consuming procedure, which can directly affect the quality of the analysis. Recent efforts have been made to establish analytical methods involving minimal sample preparation, automatized and performed online with the analytical techniques. Online Extraction coupled with Liquid Chromatography–Mass Spectrometry (OLE–LC–MS) allows a fully connected extraction, separation, and analysis system. In this work, the lecithin profile was investigated in commercial sunflower, almonds, peanuts, and pistachio seeds to demonstrate that the concept of extraction, followed by the online analysis of the extract, could be applied to analyze this class of analytes in such complex solid matrices without a prior off-line solvent extraction step. The extraction phase gradient method was optimized. Two different analytical columns were explored, one being a conventional C18 (50 × 2.1 mm, 1.7 µm SPP) and the other a novel self-packed SIGO-C18ec (100 × 0.5, 5 µm FPP), which resulted in better separation. The analysis repeatability was investigated, and suggestions to improve it were pointed out. A characteristic ion with a m/z of 184, related to lysophosphatidylcholine structure, was used to identify the lecithin compounds. The temperature effect on the chromatograms was also explored. In short, it was found that the OLE–LC–MS approach is suitable for the analysis of lecithin compounds in seeds, being a promising alternative for lipidomics approaches in the near future.
- 10 December 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1239, 340718
Application of an in-house packed octadecylsilica-functionalized graphene oxide column for capillary liquid chromatography analysis of hormones in urine samples
- 10 December 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1239, 340718
Application of an in-house packed octadecylsilica-functionalized graphene oxide column for capillary liquid chromatography analysis of hormones in urine samples