Rama Shanker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rama Shanker has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Krishna Kumar Maurya
Department of Civil Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
3 shared publications - Anupam Rawat
Department of Civil Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
2 shared publications - Achint Ranjan
Department of Civil Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
1 shared publication Ashok Gupta
Department of Civil Engineering, IIT Delhi, Hauz Khas, New Delhi, India
1 shared publication- Maheshwari Sonker
MNNIT Allahabad
1 shared publication - S. K. Singh
Motilal Nehru National Institute of Technology Allahabad, Prayagraj, India
1 shared publication
Latest Publications
- 24 November 2024
- Published by Springer Nature
- p. 369-379
Prediction of Depth of Carbonation Using Electro–Mechanical Impedance
- 24 November 2024
- Published by Springer Nature
- p. 369-379
Prediction of Depth of Carbonation Using Electro–Mechanical Impedance
- Open Access
- 26 April 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (6) , 1895
Publisher Correction to: Development of a robust structural health monitoring system: a wireless sensor network approach
- 26 April 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (6) , 1895
Open AccessPublisher Correction to: Development of a robust structural health monitoring system: a wireless sensor network approach
- 28 December 2022
- Published by Springer Nature in Biomass Conversion and Biorefinery
- Vol. 14 (11) , 11889-11909
Monitoring of biochemical based sustainable bacterial concrete system using electromechanical impedance technique with PZT sensor
- 28 December 2022
- Published by Springer Nature in Biomass Conversion and Biorefinery
- Vol. 14 (11) , 11889-11909
Monitoring of biochemical based sustainable bacterial concrete system using electromechanical impedance technique with PZT sensor
- 25 October 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (22) , 61526-61540
Prediction of remaining life of RCC sewer manhole using smart material-based EMI technique for sustainable environment
- 25 October 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (22) , 61526-61540
Prediction of remaining life of RCC sewer manhole using smart material-based EMI technique for sustainable environment
- 1 October 2022
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 58 (10) , 934-949
Determining the Sensing Region of Surface Bonded PZT Sensor and Surface Mounted PZT Sensor in Electro-Mechanical Impedance Technique for Non-Destructive Testing
Electromechanical impedance (EMI) technique is amongst the important technique in structural health monitoring field. Incipient level of damage can easily be detected through this technique as compared to other. Various PZT sensor configurations were proposed by the researcher for the EMI technique, which have their own advantages and disadvantages. In this paper surface bonded PZT sensor (SBPS) and surface mounted PZT sensor (SMPS) are used in steel I-section beam. Damages are induced in the beam and damage quantification is done using statistical tool. On comparing it was found that SMPS has more sensing region than SBPS. It is due to absence of shear lag effect in SMPS, which is not in the case of SBPS. The shear lag affects the strain transfer mechanism between the PZT sensor and host structure. The sensing region of SMPS is upto 3.5 m whereas the sensing region of SBPS is less than 2.0 m in the case of steel beam.
- 1 October 2022
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 58 (10) , 934-949
Determining the Sensing Region of Surface Bonded PZT Sensor and Surface Mounted PZT Sensor in Electro-Mechanical Impedance Technique for Non-Destructive Testing
Electromechanical impedance (EMI) technique is amongst the important technique in structural health monitoring field. Incipient level of damage can easily be detected through this technique as compared to other. Various PZT sensor configurations were proposed by the researcher for the EMI technique, which have their own advantages and disadvantages. In this paper surface bonded PZT sensor (SBPS) and surface mounted PZT sensor (SMPS) are used in steel I-section beam. Damages are induced in the beam and damage quantification is done using statistical tool. On comparing it was found that SMPS has more sensing region than SBPS. It is due to absence of shear lag effect in SMPS, which is not in the case of SBPS. The shear lag affects the strain transfer mechanism between the PZT sensor and host structure. The sensing region of SMPS is upto 3.5 m whereas the sensing region of SBPS is less than 2.0 m in the case of steel beam.
- 14 July 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (10) , 25382-25401
Health monitoring of bacterial concrete structure under dynamic loading using electro-mechanical impedance technique: a numerical approach
Health monitoring of structures using techniques based on the smart material is an innovative concept that is exploding technological revolutions in the field of civil engineering. The electro-mechanical impedance (EMI) technique is used for structural health monitoring (SHM) and to investigate the damages in the structures. The bacterial incorporation in concrete produces calcite material through metabolism process in presence of moisture and carbon dioxide, which improves the mechanical properties of concrete. Hence, its application in construction of the buildings will improve the health of structures. In this research paper, dynamic behaviour of the bacterial concrete was investigated numerically. The beams of size 700 × 150 × 150 mm of bacterial concrete and control concrete were modelled using finite element-based package ANSYS19. The beam of bacterial concrete was simulated as per the characteristics of the materials produced after the bacterial metabolism reactions. The EMI technique was applied to investigate the health of these beams. Admittance (conductance and susceptance) signatures were determined using piezo-ceramic lead zirconate titanate (PZT) sensors installed at mid-point on the top surface of concrete beams. The beams were exposed to dynamic loading and the intensity of dynamic loading was increased in four sub-steps. For the quantification of strength development in the concrete beam, the root mean square deviation (RMSD) statistical index had been applied. It was observed that the bacterial concrete beam has more resistance to the dynamic loading.
- 14 July 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (10) , 25382-25401
Health monitoring of bacterial concrete structure under dynamic loading using electro-mechanical impedance technique: a numerical approach
Health monitoring of structures using techniques based on the smart material is an innovative concept that is exploding technological revolutions in the field of civil engineering. The electro-mechanical impedance (EMI) technique is used for structural health monitoring (SHM) and to investigate the damages in the structures. The bacterial incorporation in concrete produces calcite material through metabolism process in presence of moisture and carbon dioxide, which improves the mechanical properties of concrete. Hence, its application in construction of the buildings will improve the health of structures. In this research paper, dynamic behaviour of the bacterial concrete was investigated numerically. The beams of size 700 × 150 × 150 mm of bacterial concrete and control concrete were modelled using finite element-based package ANSYS19. The beam of bacterial concrete was simulated as per the characteristics of the materials produced after the bacterial metabolism reactions. The EMI technique was applied to investigate the health of these beams. Admittance (conductance and susceptance) signatures were determined using piezo-ceramic lead zirconate titanate (PZT) sensors installed at mid-point on the top surface of concrete beams. The beams were exposed to dynamic loading and the intensity of dynamic loading was increased in four sub-steps. For the quantification of strength development in the concrete beam, the root mean square deviation (RMSD) statistical index had been applied. It was observed that the bacterial concrete beam has more resistance to the dynamic loading.
- 28 May 2012
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 364 (1) , 012126
Prediction of presence and severity of damages using experimental Mode Shape
Global dynamic technique based on frequencies change is used to detect the damages/ cracks in structures. This technique is based on changes in natural frequencies. However, it is found that changes in frequencies are negligible even in major damage cases. Several researchers have used modes shape instead of frequencies to detect the damage/ crack in structure. It is true that mode shapes approach is better compared to frequencies based analysis for damage detection; however, it fetches excellent result, if real mode shape is used. Researchers are using theoretical/ numerical/ interpolated modes shape, which produce erroneous results. In this paper, a method is proposed to extract the real mode shape of structure experimentally using only one accelerometer and damage was detected successfully in the steel beam using this mode shape. An artificial damages were created in the steel beam in four stages and the mode shapes were determined after damage for each stage. The damage was also located and severity was predicted with the help of the extracted modes shape. It was found that location predicted by proposed method was almost correct. This technique is useful for sensitive structures.
- 28 May 2012
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 364 (1) , 012126
Prediction of presence and severity of damages using experimental Mode Shape
Global dynamic technique based on frequencies change is used to detect the damages/ cracks in structures. This technique is based on changes in natural frequencies. However, it is found that changes in frequencies are negligible even in major damage cases. Several researchers have used modes shape instead of frequencies to detect the damage/ crack in structure. It is true that mode shapes approach is better compared to frequencies based analysis for damage detection; however, it fetches excellent result, if real mode shape is used. Researchers are using theoretical/ numerical/ interpolated modes shape, which produce erroneous results. In this paper, a method is proposed to extract the real mode shape of structure experimentally using only one accelerometer and damage was detected successfully in the steel beam using this mode shape. An artificial damages were created in the steel beam in four stages and the mode shapes were determined after damage for each stage. The damage was also located and severity was predicted with the help of the extracted modes shape. It was found that location predicted by proposed method was almost correct. This technique is useful for sensitive structures.