Vithor Xavier Resende de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vithor Xavier Resende de Oliveira has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guilherme José Pimentel Lopes de Oliveira
Periodontics, Universidade Federal de Uberlândia (UFU), Uberlândia, BRA
3 shared publications - Ana Paula Lima Oliveira
Faculty of Odontology, Federal University of Uberlândia, Uberlândia 38405-318, MG, Brazil
1 shared publication - Elcio Marcantonio
Sao Paulo State University
1 shared publication - Felipe Eduardo Pinotti
Universidade Estadual Paulista, Brasil
1 shared publication - Giovanna Savastano Jorge
Department of Periodontology, School of Dentistry Universidade Federal de Uberlândia – UFU Uberlândia Brazil
1 shared publication - João Vitor Goulart
Universidade Federal de Uberlândia, Brazil
1 shared publication
Latest Publications
- 11 August 2024
- Published by Wiley in Journal of Periodontal Research
- Vol. 60 (3) , 246-254
Effect of photobiomodulation with different wavelengths on periodontal repair in non‐hyperglycemic and hyperglycemic rats
Background: Hyperglycemic conditions is associated with more severe periodontitis and poorer outcomes after nonsurgical periodontal treatment (NPT). Then, these patients are candidates for adjunctive therapy associated with NPT. This study evaluates the effect of photobiomodulation (PBMT) at different wavelengths on periodontal repair in non‐hyperglycemic/hyperglycemic animals.Materials and Methods: Sixty‐four rats were submitted to induction of periodontitis by ligatures. Hyperglycemia was induced in half of these animals, whereas the other half remained non‐hyperglycemic. The animals were subdivided into 4 groups according to the PBMT protocol applied at the time of ligature removal (n = 8): CTR: Without PBMT; IRL: PBMT with infrared laser (808 nm); RL: PBMT with red laser (660 nm); and RL‐IRL: PBMT with red (660 nm) and infrared laser (808 nm). After a period of 7 days, the animals were euthanized. The parameters assessed by microtomography were the bone volume relative to total tissue volume (BV/TV%), distance from the cemento‐enamel junction to the top of the bone crest (CEJ‐CB), trabecular thickness, space between trabeculae, and number of trabeculae. Additionally, the percentage of inflammatory cells, blood vessels, and connective tissue matrix were assessed by histomorphometric analysis.Results: PBMT reduced bone loss and increased trabecular density in hyperglycemic animals (p < .05), with RL being more effective in reducing linear bone loss (CEJ‐CB), whereas RL‐IRL was more effective in maintaining BV/TV%. PBMT reduced blood vessels and increased the connective tissue component in hyperglycemic animals (p < .05). RL‐IRL reduced inflammatory cells regardless of the systemic condition of the animal (p < .05).Conclusion: PBMT (RL, RL‐IRL) improves the repair of periodontal tissues in hyperglycemic animals.
- 11 August 2024
- Published by Wiley in Journal of Periodontal Research
- Vol. 60 (3) , 246-254
Effect of photobiomodulation with different wavelengths on periodontal repair in non‐hyperglycemic and hyperglycemic rats
Background: Hyperglycemic conditions is associated with more severe periodontitis and poorer outcomes after nonsurgical periodontal treatment (NPT). Then, these patients are candidates for adjunctive therapy associated with NPT. This study evaluates the effect of photobiomodulation (PBMT) at different wavelengths on periodontal repair in non‐hyperglycemic/hyperglycemic animals.Materials and Methods: Sixty‐four rats were submitted to induction of periodontitis by ligatures. Hyperglycemia was induced in half of these animals, whereas the other half remained non‐hyperglycemic. The animals were subdivided into 4 groups according to the PBMT protocol applied at the time of ligature removal (n = 8): CTR: Without PBMT; IRL: PBMT with infrared laser (808 nm); RL: PBMT with red laser (660 nm); and RL‐IRL: PBMT with red (660 nm) and infrared laser (808 nm). After a period of 7 days, the animals were euthanized. The parameters assessed by microtomography were the bone volume relative to total tissue volume (BV/TV%), distance from the cemento‐enamel junction to the top of the bone crest (CEJ‐CB), trabecular thickness, space between trabeculae, and number of trabeculae. Additionally, the percentage of inflammatory cells, blood vessels, and connective tissue matrix were assessed by histomorphometric analysis.Results: PBMT reduced bone loss and increased trabecular density in hyperglycemic animals (p < .05), with RL being more effective in reducing linear bone loss (CEJ‐CB), whereas RL‐IRL was more effective in maintaining BV/TV%. PBMT reduced blood vessels and increased the connective tissue component in hyperglycemic animals (p < .05). RL‐IRL reduced inflammatory cells regardless of the systemic condition of the animal (p < .05).Conclusion: PBMT (RL, RL‐IRL) improves the repair of periodontal tissues in hyperglycemic animals.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5632
Effect of different thread configurations on hydrophilic implant stability. A split-mouth RCT
This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5632
Open AccessEffect of different thread configurations on hydrophilic implant stability. A split-mouth RCT
This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.
- Open Access
- 7 March 2022
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 33 (1) , 105-111
Comparison of osseointegration in areas grafted with different osteoconductive biomaterials. Preclinical study
This study evaluated osseointegration in areas grafted with deproteinized bovine bone (DBB) and biphasic ceramic based on hydroxyapatite and beta-tricalcium phosphate (HA/TCP) in rat tibias. Noncritical bone defects were made in the tibias of 28 rats that were randomly assigned to 2 groups: DBB: DBB-filled defects and HA/TCP: HA/TCP-filled defects. Bone defects were made in the tibias bilaterally and filled with biomaterials. After 60 days, the implants were inserted, and the animals were euthanized 15 and 45 days after the implants were installed. Osseointegration was evaluated by biomechanical, microtomographic and histometric analysis. Implants installed in the defects filled with DBB presented higher removal torque forces (2.33 ± 0.51 Ncm vs. 1.50 ± 0.54 Ncm) and mineralized tissue volume around implants at 15 days (34.96 ± 3.68 % vs. 25.61 ± 2.95 %) and greater bone-implant contact (20.87 ± 8.28 % vs. 11.52 ± 7.42 %) and bone area within implant threads (26.83 ± 12.35 % vs. 11.98 ± 7.56 %) at 45 days compared to the measurements of implants in areas grafted with HA/TCP. Implants installed in defects in areas grafted with DBB had a better osseointegration pattern than implants placed in defects in areas grafted with HA/TCP.
- 7 March 2022
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 33 (1) , 105-111
Open AccessComparison of osseointegration in areas grafted with different osteoconductive biomaterials. Preclinical study
This study evaluated osseointegration in areas grafted with deproteinized bovine bone (DBB) and biphasic ceramic based on hydroxyapatite and beta-tricalcium phosphate (HA/TCP) in rat tibias. Noncritical bone defects were made in the tibias of 28 rats that were randomly assigned to 2 groups: DBB: DBB-filled defects and HA/TCP: HA/TCP-filled defects. Bone defects were made in the tibias bilaterally and filled with biomaterials. After 60 days, the implants were inserted, and the animals were euthanized 15 and 45 days after the implants were installed. Osseointegration was evaluated by biomechanical, microtomographic and histometric analysis. Implants installed in the defects filled with DBB presented higher removal torque forces (2.33 ± 0.51 Ncm vs. 1.50 ± 0.54 Ncm) and mineralized tissue volume around implants at 15 days (34.96 ± 3.68 % vs. 25.61 ± 2.95 %) and greater bone-implant contact (20.87 ± 8.28 % vs. 11.52 ± 7.42 %) and bone area within implant threads (26.83 ± 12.35 % vs. 11.98 ± 7.56 %) at 45 days compared to the measurements of implants in areas grafted with HA/TCP. Implants installed in defects in areas grafted with DBB had a better osseointegration pattern than implants placed in defects in areas grafted with HA/TCP.