Lipika Nanda
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lipika Nanda has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arjyadhara Pradhan
KIIT Deemed to be University
5 shared publications Arjyadhara Pradhan
KIIT Deemed to be University
3 shared publicationsBabita Panda
KIIT Deemed to be University
3 shared publicationsChitralekha Jena
KIIT Deemed to be University
3 shared publications- Babita Panda
KIIT
2 shared publications - Babita Panda
School of Electrical Engineering, KIIT Deemed to be University, Bhubaneswar, Odisha, India
2 shared publications
Latest Publications
- 2 October 2024
- Published by Springer Nature
- p. 227-234
A High Step-Up DC/DC Converter by Using PV Power System and Its Applications
- 2 October 2024
- Published by Springer Nature
- p. 227-234
A High Step-Up DC/DC Converter by Using PV Power System and Its Applications
- 17 January 2024
- Published by Suranaree University of Technology in Suranaree Journal of Science and Technology
- Vol. 30 (6) , 010260(1-6)
ENERGY & EXERGY ANALYSIS OF A PV PANEL WITH PASSIVE COOLING MECHANISM
A photovoltaic (PV) array is grately responsive to changes in temperature; contrarily, reduction in temperature is the major factor that subsidize to an raise in the electrical efficiency and output power of a PV system. To optimize the production of energy by PV panels and reduce their temperature, a photovoltaic (PV) cooling system is basically used. Nonetheless, more insolation is generally associated with higher temperatures, which is ambiguous for photovoltaic (PV) panels because they rely on that irradiance to create power. These extreme temperature rises have a devastating effect on how skillfully photovoltaic (PV) panels transforms energy. A solar photovoltaic (PV) system can opearte more accurately with an adequate cooling system on its surface. In this paper, a passive cooling model for the PV panel has been devloped which cools down the PV panel by employing dry grass and water at the back surface. A correlation has been made with a non-cooled panel. Two PV panels are simultaneously tested. Electrical output properties of both the PV panels have been recorded and energy and exergy analysis for the system has been presented to have a more detailed understanding of the cooling effect on PV panel performance. The cooled panel has an increase in efficiency by 47%. Along with the electrical efficiency, the thermal efficiency has also been presented in this paper for performance evaluation in the form of overall efficiency.
- 17 January 2024
- Published by Suranaree University of Technology in Suranaree Journal of Science and Technology
- Vol. 30 (6) , 010260(1-6)
ENERGY & EXERGY ANALYSIS OF A PV PANEL WITH PASSIVE COOLING MECHANISM
A photovoltaic (PV) array is grately responsive to changes in temperature; contrarily, reduction in temperature is the major factor that subsidize to an raise in the electrical efficiency and output power of a PV system. To optimize the production of energy by PV panels and reduce their temperature, a photovoltaic (PV) cooling system is basically used. Nonetheless, more insolation is generally associated with higher temperatures, which is ambiguous for photovoltaic (PV) panels because they rely on that irradiance to create power. These extreme temperature rises have a devastating effect on how skillfully photovoltaic (PV) panels transforms energy. A solar photovoltaic (PV) system can opearte more accurately with an adequate cooling system on its surface. In this paper, a passive cooling model for the PV panel has been devloped which cools down the PV panel by employing dry grass and water at the back surface. A correlation has been made with a non-cooled panel. Two PV panels are simultaneously tested. Electrical output properties of both the PV panels have been recorded and energy and exergy analysis for the system has been presented to have a more detailed understanding of the cooling effect on PV panel performance. The cooled panel has an increase in efficiency by 47%. Along with the electrical efficiency, the thermal efficiency has also been presented in this paper for performance evaluation in the form of overall efficiency.
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Control Strategy for DC to DC Converter using MLP embedded Actor-Critic Architecture
Buck-boost DC to DC converters find a huge application in the industry for acquiring a constant DC output voltage. Due to the instability issues caused by the constant power loads, there has always been a requirement for adaptive control strategies that shall control and hence stabilize the voltage. In this paper, we have proposed an enhanced multilayered perceptron embedded in the actor-critic architecture to control the voltage variations. A PPO-based tuner consisting of the MLP has been used which produces coefficients that can be fed directly to our closed-loop feedback controller for the self-adaptive control system. The input and output sets have been analyzed along with appropriate hyperparameter tuning of the neural network within. Considering the seasonality of the data distribution of the input voltage, an appropriate training method has been used, ensuring the optimal real-time performance of the controller.
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Control Strategy for DC to DC Converter using MLP embedded Actor-Critic Architecture
Buck-boost DC to DC converters find a huge application in the industry for acquiring a constant DC output voltage. Due to the instability issues caused by the constant power loads, there has always been a requirement for adaptive control strategies that shall control and hence stabilize the voltage. In this paper, we have proposed an enhanced multilayered perceptron embedded in the actor-critic architecture to control the voltage variations. A PPO-based tuner consisting of the MLP has been used which produces coefficients that can be fed directly to our closed-loop feedback controller for the self-adaptive control system. The input and output sets have been analyzed along with appropriate hyperparameter tuning of the neural network within. Considering the seasonality of the data distribution of the input voltage, an appropriate training method has been used, ensuring the optimal real-time performance of the controller.
- 22 September 2022
- Published by Springer Nature
- p. 377-387
Hardware Testing of the Effect of MPPT on the Performance of Photovoltaic Panels
- 22 September 2022
- Published by Springer Nature
- p. 377-387
Hardware Testing of the Effect of MPPT on the Performance of Photovoltaic Panels
- 22 September 2022
- Published by Springer Nature
- p. 37-44
Simulation Result Analysis of a Proposed Cross Connected Switch Capacitor Multi Level Inverter Topology
- 22 September 2022
- Published by Springer Nature
- p. 37-44
Simulation Result Analysis of a Proposed Cross Connected Switch Capacitor Multi Level Inverter Topology
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Analysis of dust on the parameters of PV module and design of an effective solar dust cleaner
Photovoltaic panel output is affected by various factors like solar isolation, temperature, dust, shading, mounting. Among all these factors dust is a prominent factor which greatly reduces panel efficiency. With increase in the quantity of dust both efficiency and power output of the module reduces. As the mass of dust deposition increases, power output and the efficiency of the module decreases. Dust particles are of different shapes and sizes. PV panels installed on ground or roof top are subjected to dust all the time. The amount and type of dust deposition depends on tilt angle, locations, surroundings nearby, rainfall pattern of that area, maintenance method of the installer. PV plant nearby any industry giving out lot of fumes and smokes will have heavy dust deposition over its top surface. Similarly, PV plants located near areas where roads are not concrete can cause dust deposition on its panels. Manual maintenance is labor costing and less efficient. In this work we have performed dust analysis on the performance of PV panel and designed an effective method to clean the panel and make it dust free. Solar dust cleaner and cooler system provides a solution for both dusts cleaning and keeping the panels at less temperature.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessAnalysis of dust on the parameters of PV module and design of an effective solar dust cleaner
Photovoltaic panel output is affected by various factors like solar isolation, temperature, dust, shading, mounting. Among all these factors dust is a prominent factor which greatly reduces panel efficiency. With increase in the quantity of dust both efficiency and power output of the module reduces. As the mass of dust deposition increases, power output and the efficiency of the module decreases. Dust particles are of different shapes and sizes. PV panels installed on ground or roof top are subjected to dust all the time. The amount and type of dust deposition depends on tilt angle, locations, surroundings nearby, rainfall pattern of that area, maintenance method of the installer. PV plant nearby any industry giving out lot of fumes and smokes will have heavy dust deposition over its top surface. Similarly, PV plants located near areas where roads are not concrete can cause dust deposition on its panels. Manual maintenance is labor costing and less efficient. In this work we have performed dust analysis on the performance of PV panel and designed an effective method to clean the panel and make it dust free. Solar dust cleaner and cooler system provides a solution for both dusts cleaning and keeping the panels at less temperature.
- 25 May 2022
- Published by Springer Nature
- p. 45-54
A Cross-connected Switch Capacitor Multilevel Inverter: A Proposed Topology and Its Analysis
- 25 May 2022
- Published by Springer Nature
- p. 45-54
A Cross-connected Switch Capacitor Multilevel Inverter: A Proposed Topology and Its Analysis
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The Development and Analysis of a Novel Multilevel Inverter Topology with Reduced Device Count
A novel MLI structure is developed. First, 9-Level basic MLI structure has been developed and analyzed for minimal and maximum frequency modulation scheme. Further, an extended structure has been developed to execute additional output voltage levels using minimal components. The voltage stress analysis, power losses analysis and comparison study have been determined in detail. The proposed structure uses minimal components and sustains lower TSV on estimation with other structures. The simulation evaluation of the basic 9-Level structure has been presented to validate its merits and effectiveness.
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
The Development and Analysis of a Novel Multilevel Inverter Topology with Reduced Device Count
A novel MLI structure is developed. First, 9-Level basic MLI structure has been developed and analyzed for minimal and maximum frequency modulation scheme. Further, an extended structure has been developed to execute additional output voltage levels using minimal components. The voltage stress analysis, power losses analysis and comparison study have been determined in detail. The proposed structure uses minimal components and sustains lower TSV on estimation with other structures. The simulation evaluation of the basic 9-Level structure has been presented to validate its merits and effectiveness.
- Open Access
- 1 March 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (1)
A proposed asymmetrical configuration of cascaded multilevel inverter topology for high level generation
Multilevel inverters are having high demand in high power applications. It works in medium voltage range. In this converter, for specific time intervals fewer switches will be conducting so switching loss is also reduced. This paper represents overall total harmonic distortion (THD) for different levels and different carrier frequencies. Switching loss, conduction loss of inverter has been discussed and hence inverter efficiency can be calculated. Phase displacement pulse width modulation method has been proposed in order to generate pulses. The proposed topology is well presented by its practical implementation with two current direct sources. All the simulations are being carried out using MATLAB/Simulink platform to validate the hardware results.
- 1 March 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (1)
Open AccessA proposed asymmetrical configuration of cascaded multilevel inverter topology for high level generation
Multilevel inverters are having high demand in high power applications. It works in medium voltage range. In this converter, for specific time intervals fewer switches will be conducting so switching loss is also reduced. This paper represents overall total harmonic distortion (THD) for different levels and different carrier frequencies. Switching loss, conduction loss of inverter has been discussed and hence inverter efficiency can be calculated. Phase displacement pulse width modulation method has been proposed in order to generate pulses. The proposed topology is well presented by its practical implementation with two current direct sources. All the simulations are being carried out using MATLAB/Simulink platform to validate the hardware results.