Pedram Nojedehi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pedram Nojedehi has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Burak Gunay
5 shared publications- Marcel Schweiker
Healthy Living Spaces lab, Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
3 shared publications - Burak Gunay
Carleton University, Ottawa, Canada
2 shared publications - Elie Azar
Civil and Environmental Engineering Dept, Carleton University, Ottawa, Canada
2 shared publications - Maya Papineau
Carleton University, Ottawa, ON, Canada
2 shared publications William O'BRien
2 shared publications
Latest Publications
- Open Access
- 11 October 2026
- Published by Elsevier in SSRN Electronic Journal
From Monitoring to Probabilistic Profiles: Energy Use and Indoor Environmental Conditions in Retrofitted Social Housing
Community-scale residential retrofit programs require building energy models that represent differences in occupant behaviour and system operation among dwellings. However, these models often rely on fixed assumptions that may not reflect household variability. This study investigates this variability using one year of high frequency monitoring from ten retrofitted social housing dwellings in Ottawa, Canada, with similar envelope characteristics and identical retrofit technologies. Indoor temperature, relative humidity, carbon dioxide concentration, HVAC equipment electricity use, and outdoor weather conditions were monitored and analyzed to characterize occupancy patterns, thermostat related conditions, heat pump operation, domestic hot water demand and schedules, and household electrical energy use. Heat pump to furnace transition temperatures were estimated from observed equipment operation across outdoor temperatures. Monitored results were compared with relevant Canadian standard assumptions and translated into probability ranges of P10, P25, P50, P75, and P90 and representative schedules. Median heating and cooling setpoints are 22.1°C and 21.4°C, median domestic hot water use is 68.7 L/person/day, and the median heat pump transition temperature is -17.2°C, with wide variation among households. Results show that dwellings with similar physical characteristics and identical retrofit technologies can exhibit different operating conditions and energy use. Uniform assumptions can mask differences in household behaviour, equipment control, and demand timing. The resulting distributions and schedules provide monitoring-based inputs for community energy models and can support behavioural retrofit packages representing very low to very high consumption conditions, enabling more realistic evaluation of annual energy use, peak electricity demand, operational carbon emissions, and achievable retrofit performance.
- 11 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFrom Monitoring to Probabilistic Profiles: Energy Use and Indoor Environmental Conditions in Retrofitted Social Housing
Community-scale residential retrofit programs require building energy models that represent differences in occupant behaviour and system operation among dwellings. However, these models often rely on fixed assumptions that may not reflect household variability. This study investigates this variability using one year of high frequency monitoring from ten retrofitted social housing dwellings in Ottawa, Canada, with similar envelope characteristics and identical retrofit technologies. Indoor temperature, relative humidity, carbon dioxide concentration, HVAC equipment electricity use, and outdoor weather conditions were monitored and analyzed to characterize occupancy patterns, thermostat related conditions, heat pump operation, domestic hot water demand and schedules, and household electrical energy use. Heat pump to furnace transition temperatures were estimated from observed equipment operation across outdoor temperatures. Monitored results were compared with relevant Canadian standard assumptions and translated into probability ranges of P10, P25, P50, P75, and P90 and representative schedules. Median heating and cooling setpoints are 22.1°C and 21.4°C, median domestic hot water use is 68.7 L/person/day, and the median heat pump transition temperature is -17.2°C, with wide variation among households. Results show that dwellings with similar physical characteristics and identical retrofit technologies can exhibit different operating conditions and energy use. Uniform assumptions can mask differences in household behaviour, equipment control, and demand timing. The resulting distributions and schedules provide monitoring-based inputs for community energy models and can support behavioural retrofit packages representing very low to very high consumption conditions, enabling more realistic evaluation of annual energy use, peak electricity demand, operational carbon emissions, and achievable retrofit performance.
- Open Access
- 6 April 2026
- Published by Elsevier in SSRN Electronic Journal
Passive Cooling Retrofits for Mitigating Indoor Overheating in Canadian Single-Family Housing under Future Extreme Climates
Overheating has become an increasing concern in Canadian housing, as the current housing stock was designed for climates in which summertime overheating was not historically considered a critical design constraint. This study develops three representative single-family housing archetypes reflecting major energy-performance tiers of the Canadian housing stock, informed by national energy codes and the EnerGuide for Houses database. Using dynamic building energy simulations, a suite of scalable low-cost passive cooling retrofit strategies was evaluated under both historical and projected future climates. The analysis considered alternative natural ventilation behaviours representing both ideal conditions and constrained scenarios associated with climate change impacts or limited occupant adaptability. Results show that under free-running conditions with windows closed, operative-temperature exceedance can reach 12-15% of annual hours by the end of the century, while adaptive ventilation substantially mitigates overheating. The proposed passive strategies further reduce overheating risk by roughly 15-21%, and cooling demand by 20-40%. However, future climate warming still leads to significant risks, particularly in older housing archetypes. A mismatch of 5-13% in overheating assessment is observed between dry-bulb temperature and operative temperature metrics. These findings suggest that passive retrofits and adaptive ventilation improve thermal resilience but do not fully offset future overheating risks, highlighting the need for improved operational controls and, in some cases, mechanical cooling.
- 6 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPassive Cooling Retrofits for Mitigating Indoor Overheating in Canadian Single-Family Housing under Future Extreme Climates
Overheating has become an increasing concern in Canadian housing, as the current housing stock was designed for climates in which summertime overheating was not historically considered a critical design constraint. This study develops three representative single-family housing archetypes reflecting major energy-performance tiers of the Canadian housing stock, informed by national energy codes and the EnerGuide for Houses database. Using dynamic building energy simulations, a suite of scalable low-cost passive cooling retrofit strategies was evaluated under both historical and projected future climates. The analysis considered alternative natural ventilation behaviours representing both ideal conditions and constrained scenarios associated with climate change impacts or limited occupant adaptability. Results show that under free-running conditions with windows closed, operative-temperature exceedance can reach 12-15% of annual hours by the end of the century, while adaptive ventilation substantially mitigates overheating. The proposed passive strategies further reduce overheating risk by roughly 15-21%, and cooling demand by 20-40%. However, future climate warming still leads to significant risks, particularly in older housing archetypes. A mismatch of 5-13% in overheating assessment is observed between dry-bulb temperature and operative temperature metrics. These findings suggest that passive retrofits and adaptive ventilation improve thermal resilience but do not fully offset future overheating risks, highlighting the need for improved operational controls and, in some cases, mechanical cooling.
- Open Access
- 1 November 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3140 (2)
Fault detection and severity classification in HVAC fan coil units using a hybrid autoencoder-based method
Efficient HVAC operation is vital to reduce energy waste and discomfort, but systems often face various faults. As automation grows, there is a pressing need for fault detection methods that go beyond basic identification. This study presents a hybrid fault detection framework for fan coil units (FCUs) that leverages simulated fault-labelled data for evaluation and unsupervised learning for anomaly detection. An autoencoder model is trained exclusively on fault-free operational data to learn the normal behaviour of the system. Reconstruction errors from the autoencoder are used to detect anomalies, and a sensitivity analysis is conducted to determine optimal percentile-based thresholds across multiple fault scenarios. These fault specific thresholds are then generalized into three global severity bands based on their statistical distribution. The methodology is validated using a high-fidelity simulated dataset representing an independent fault scenario in a four-pipe FCU system. A test case involving a reverse-acting control fault shows that severity levels correspond to increasing heating and cooling loads, confirming the operational impact of anomaly classification. The proposed approach enables early fault detection, severity quantification, and energy-aware prioritization of maintenance tasks, offering a scalable solution for integration into building automation and facility management systems.
- 1 November 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3140 (2)
Open AccessFault detection and severity classification in HVAC fan coil units using a hybrid autoencoder-based method
Efficient HVAC operation is vital to reduce energy waste and discomfort, but systems often face various faults. As automation grows, there is a pressing need for fault detection methods that go beyond basic identification. This study presents a hybrid fault detection framework for fan coil units (FCUs) that leverages simulated fault-labelled data for evaluation and unsupervised learning for anomaly detection. An autoencoder model is trained exclusively on fault-free operational data to learn the normal behaviour of the system. Reconstruction errors from the autoencoder are used to detect anomalies, and a sensitivity analysis is conducted to determine optimal percentile-based thresholds across multiple fault scenarios. These fault specific thresholds are then generalized into three global severity bands based on their statistical distribution. The methodology is validated using a high-fidelity simulated dataset representing an independent fault scenario in a four-pipe FCU system. A test case involving a reverse-acting control fault shows that severity levels correspond to increasing heating and cooling loads, confirming the operational impact of anomaly classification. The proposed approach enables early fault detection, severity quantification, and energy-aware prioritization of maintenance tasks, offering a scalable solution for integration into building automation and facility management systems.
- Open Access
- 24 September 2025
- Published by Elsevier in Energy and Buildings
- Vol. 348
A review of passive design strategies and their effect on thermal resilience in low-income households
- 24 September 2025
- Published by Elsevier in Energy and Buildings
- Vol. 348
Open AccessA review of passive design strategies and their effect on thermal resilience in low-income households
- Open Access
- 26 August 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Do homebuyers prioritize sustainability? Examining the GHG emission impact of housing choices
- 26 August 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Open AccessDo homebuyers prioritize sustainability? Examining the GHG emission impact of housing choices
- Open Access
- 24 August 2025
- Published by Elsevier in Energy and Buildings
- Vol. 347
A method to develop residential archetypes by associating thermophysical building attributes with utility meter data
- 24 August 2025
- Published by Elsevier in Energy and Buildings
- Vol. 347
Open AccessA method to develop residential archetypes by associating thermophysical building attributes with utility meter data
- 5 September 2024
- Published by Elsevier in Energy Policy
- Vol. 194
Examining disparities in energy poverty and indoor environmental quality satisfaction among Canadian households
- 5 September 2024
- Published by Elsevier in Energy Policy
- Vol. 194
Examining disparities in energy poverty and indoor environmental quality satisfaction among Canadian households
- 11 July 2023
- Published by Elsevier in Building and Environment
- Vol. 242
Deployment of crowdsourced occupant data to support fault detection and diagnosis in buildings
- 11 July 2023
- Published by Elsevier in Building and Environment
- Vol. 242
Deployment of crowdsourced occupant data to support fault detection and diagnosis in buildings
- Open Access
- 2 May 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 230
Thermo-economic assessment and optimization of a multigeneration system powered by geothermal and solar energy
- 2 May 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 230
Open AccessThermo-economic assessment and optimization of a multigeneration system powered by geothermal and solar energy
- 11 April 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (8) , 1097-1114
A methodology to integrate maintenance management systems and BIM to improve building management
Facility management (FM) teams routinely deal with numerous tasks, tools, and data sources to ensure the buildings they manage function properly. This diversity and the organizational complexity of these teams increase operational expenses related to interoperability. To address this, a methodology integrating BIM with maintenance management system logs is investigated herein. It includes two novel ways of automatically exchanging and visualizing such data using BIM as a common data environment. They provide building operators with greater context to expedite the decision-making process. A sequence diagram based on a typical facility management organization illustrates that these tools improve data exchange efficiency by which the operators understand the data and target operational improvements better. This methodology reduces the dependency on external programming languages for data processing. A text mining workflow is leveraged to process the work order (WO) descriptions. The methodology is demonstrated using a case study, which indicates that only 47 out of 81 rooms have one or more WOs and over 60% of all WOs are related to five rooms on the top floor. By focusing on these spaces, the underlying reasons and patterns of the faults were identified, which enhances the productivity of FM teams, occupants, and energy efficiency.
- 11 April 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (8) , 1097-1114
A methodology to integrate maintenance management systems and BIM to improve building management
Facility management (FM) teams routinely deal with numerous tasks, tools, and data sources to ensure the buildings they manage function properly. This diversity and the organizational complexity of these teams increase operational expenses related to interoperability. To address this, a methodology integrating BIM with maintenance management system logs is investigated herein. It includes two novel ways of automatically exchanging and visualizing such data using BIM as a common data environment. They provide building operators with greater context to expedite the decision-making process. A sequence diagram based on a typical facility management organization illustrates that these tools improve data exchange efficiency by which the operators understand the data and target operational improvements better. This methodology reduces the dependency on external programming languages for data processing. A text mining workflow is leveraged to process the work order (WO) descriptions. The methodology is demonstrated using a case study, which indicates that only 47 out of 81 rooms have one or more WOs and over 60% of all WOs are related to five rooms on the top floor. By focusing on these spaces, the underlying reasons and patterns of the faults were identified, which enhances the productivity of FM teams, occupants, and energy efficiency.