Linlin Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Linlin Wu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Bowei Li
Electrical Enginneering, Shandong University, Jinan China
1 shared publication - Chenyu Liu
College of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300401, China
1 shared publication Hui Liu
State Grid Jibei Electric Power Co. Ltd. Research Institute Beijing People's Republic of China
1 shared publication- Hui Liu
State Grid Jibei Electric Power Co., Ltd., Research Institute, Beijing 100045, China
1 shared publication - Jiaan Zhang
School of Electrical Engineering, Hebei University of Technology, Tianjin 300401, China
1 shared publication - Jingwei Li
College of Artificial Intelligence and Data Science, Hebei University of Technology, Tianjin 300401, China
1 shared publication
Latest Publications
- Open Access
Modeling and Operational Characteristic Analysis of Four-Port P2H DC Microgrids Based on a Hierarchical Multimodal Coordinated Control Strategy
The integration of photovoltaic (PV) generation with alkaline water electrolyzers (AWE) in DC microgrids offers a highly promising pathway for green hydrogen production. However, the inherent volatility of solar power often induces transient voltage ripples and power surges, degrading the electrolyzer stack and destabilizing the common DC bus. To overcome this, this study proposes a hierarchical multimodal coordinated control strategy tailored for a four-port (PV–Storage–Grid–Hydrogen) DC microgrid. The proposed framework leverages multi-port synergetic coordination among the PV array, battery storage, and grid-interfacing converters to actively buffer extreme power mismatches, thereby ensuring the constant regulation of the DC bus voltage. Through comprehensive time-domain simulations under worst-case step-change boundary conditions, the large-signal transient stability of the proposed strategy is quantitatively verified. Under extreme disturbances, the system successfully confines DC bus voltage deviations to within safe operational boundaries with a rapid settling time, effectively avoiding typical inverter overvoltage trip thresholds. Furthermore, the adaptive power regulation algorithm maintains precise steady-state power tracking. By utilizing a gradient-based flag variable, the system seamlessly transitions between maximum power point tracking (MPPT) and active power-limiting modes, ensuring continuous equipment protection, stable high-purity hydrogen yield, and uninterrupted microgrid stability.
Open AccessModeling and Operational Characteristic Analysis of Four-Port P2H DC Microgrids Based on a Hierarchical Multimodal Coordinated Control Strategy
The integration of photovoltaic (PV) generation with alkaline water electrolyzers (AWE) in DC microgrids offers a highly promising pathway for green hydrogen production. However, the inherent volatility of solar power often induces transient voltage ripples and power surges, degrading the electrolyzer stack and destabilizing the common DC bus. To overcome this, this study proposes a hierarchical multimodal coordinated control strategy tailored for a four-port (PV–Storage–Grid–Hydrogen) DC microgrid. The proposed framework leverages multi-port synergetic coordination among the PV array, battery storage, and grid-interfacing converters to actively buffer extreme power mismatches, thereby ensuring the constant regulation of the DC bus voltage. Through comprehensive time-domain simulations under worst-case step-change boundary conditions, the large-signal transient stability of the proposed strategy is quantitatively verified. Under extreme disturbances, the system successfully confines DC bus voltage deviations to within safe operational boundaries with a rapid settling time, effectively avoiding typical inverter overvoltage trip thresholds. Furthermore, the adaptive power regulation algorithm maintains precise steady-state power tracking. By utilizing a gradient-based flag variable, the system seamlessly transitions between maximum power point tracking (MPPT) and active power-limiting modes, ensuring continuous equipment protection, stable high-purity hydrogen yield, and uninterrupted microgrid stability.
- Open Access
- 20 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (20) , 11218
Research on the CSODC Strategy Based on Impedance Model Prediction and SSO Stability Assessment of DFIGs
As wind power penetration continues to increase, the sub-synchronous control interaction (SSCI) problem caused by the interaction between doubly fed induction generators (DFIGs) and series-compensated transmission lines has become increasingly prominent, posing a serious threat to power system stability. To address this problem, this research proposes a centralized sub-synchronous oscillation damping controller (CSODC) for wind farms. First, a DFIG impedance model was constructed based on multi-operating-point impedance scanning and a Taylor series expansion, achieving impedance prediction with an error of less than 2% under various power conditions. Subsequently, a CSODC comprising a sub-synchronous damping calculator (SSDC) and a power electronic converter is designed. By optimizing feedback signals, phase shift angles, gain parameters, and filter parameters, dynamic adjustment of controllable impedance in the sub-synchronous frequency band is achieved. Frequency-domain impedance analysis demonstrates that the CSODC significantly enhances the system’s equivalent resistance, reversing it from negative to positive at the resonance frequency point. Time-domain simulations validated the CSODC’s effectiveness in scenarios involving series capacitor switching and wind speed disturbances, demonstrating rapid sub-synchronous current decay. The results confirm that the proposed strategy effectively suppresses sub-synchronous oscillations across multiple scenarios, offering an economical and efficient solution to stability challenges in high-penetration renewable energy grids.
- 20 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (20) , 11218
Open AccessResearch on the CSODC Strategy Based on Impedance Model Prediction and SSO Stability Assessment of DFIGs
As wind power penetration continues to increase, the sub-synchronous control interaction (SSCI) problem caused by the interaction between doubly fed induction generators (DFIGs) and series-compensated transmission lines has become increasingly prominent, posing a serious threat to power system stability. To address this problem, this research proposes a centralized sub-synchronous oscillation damping controller (CSODC) for wind farms. First, a DFIG impedance model was constructed based on multi-operating-point impedance scanning and a Taylor series expansion, achieving impedance prediction with an error of less than 2% under various power conditions. Subsequently, a CSODC comprising a sub-synchronous damping calculator (SSDC) and a power electronic converter is designed. By optimizing feedback signals, phase shift angles, gain parameters, and filter parameters, dynamic adjustment of controllable impedance in the sub-synchronous frequency band is achieved. Frequency-domain impedance analysis demonstrates that the CSODC significantly enhances the system’s equivalent resistance, reversing it from negative to positive at the resonance frequency point. Time-domain simulations validated the CSODC’s effectiveness in scenarios involving series capacitor switching and wind speed disturbances, demonstrating rapid sub-synchronous current decay. The results confirm that the proposed strategy effectively suppresses sub-synchronous oscillations across multiple scenarios, offering an economical and efficient solution to stability challenges in high-penetration renewable energy grids.
- Open Access
Identification of Control Parameters for Converters of Doubly Fed Wind Turbines Based on Hybrid Genetic Algorithm
The accuracy of doubly fed induction generator (DFIG) models and parameters plays an important role in power system operation. This paper proposes a parameter identification method based on the hybrid genetic algorithm for the control system of DFIG converters. In the improved genetic algorithm, the generation gap value and immune strategy are adopted, and a strategy of “individual identification, elite retention, and overall identification” is proposed. The DFIG operation data information used for parameter identification considers the loss of rotor current, stator current, grid-side voltage, stator voltage, and rotor voltage. The operating data of a wind farm in Zhangjiakou, North China, were used as a test case to verify the effectiveness of the proposed parameter identification method for the Maximum Power Point Tracking (MPPT), constant speed, and constant power operation conditions of the wind turbine.
Open AccessIdentification of Control Parameters for Converters of Doubly Fed Wind Turbines Based on Hybrid Genetic Algorithm
The accuracy of doubly fed induction generator (DFIG) models and parameters plays an important role in power system operation. This paper proposes a parameter identification method based on the hybrid genetic algorithm for the control system of DFIG converters. In the improved genetic algorithm, the generation gap value and immune strategy are adopted, and a strategy of “individual identification, elite retention, and overall identification” is proposed. The DFIG operation data information used for parameter identification considers the loss of rotor current, stator current, grid-side voltage, stator voltage, and rotor voltage. The operating data of a wind farm in Zhangjiakou, North China, were used as a test case to verify the effectiveness of the proposed parameter identification method for the Maximum Power Point Tracking (MPPT), constant speed, and constant power operation conditions of the wind turbine.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1146-1157
Operating Region and Boundary Control of Modular Multilevel Converter Station Under Unbalanced Grid Conditions
To determine the operating region of modular multilevel converter (MMC) station under unbalance grid conditions, this paper proposes the analytical and point-scanning methods. First, the imbalance of PCC voltages is expressed in terms of two proposed indexes for single phase fault (SPF), which can be directly calculated from the grid parameter and grounding impedance. Next, the algebraic equation to solve the PCC voltage for the given PCC power is presented. The existence of PCC voltage is considered as one constraint. Moreover, the other constraints for transformer rating, converter rating, ac current and output voltage are also analyzed to adapt the unbalance conditions. Based on the proposed method, the effect of the grid imbalance on the operating region of MMC is analyzed and then the common constraints to confine the operating region are determined. Following that, the boundary control is proposed to limit the operation of MMC on the boundary of the operating region under unbalanced conditions. The open and modular control structure allows more constraints to be considered for the boundary control. The simulation results validate the correctness of the proposed methods to define the operating region and the effectiveness of the boundary control.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1146-1157
Operating Region and Boundary Control of Modular Multilevel Converter Station Under Unbalanced Grid Conditions
To determine the operating region of modular multilevel converter (MMC) station under unbalance grid conditions, this paper proposes the analytical and point-scanning methods. First, the imbalance of PCC voltages is expressed in terms of two proposed indexes for single phase fault (SPF), which can be directly calculated from the grid parameter and grounding impedance. Next, the algebraic equation to solve the PCC voltage for the given PCC power is presented. The existence of PCC voltage is considered as one constraint. Moreover, the other constraints for transformer rating, converter rating, ac current and output voltage are also analyzed to adapt the unbalance conditions. Based on the proposed method, the effect of the grid imbalance on the operating region of MMC is analyzed and then the common constraints to confine the operating region are determined. Following that, the boundary control is proposed to limit the operation of MMC on the boundary of the operating region under unbalanced conditions. The open and modular control structure allows more constraints to be considered for the boundary control. The simulation results validate the correctness of the proposed methods to define the operating region and the effectiveness of the boundary control.
- Open Access
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1809-1813
Research on smart tracking strategy of wind power and energy storage combined generation system based on three‐stage rolling optimisation
Wind power consumption has become a bottleneck in the development of wind power. Based on the energy storage's redistribution ability of wind power in time scale, the utilisation efficiency of wind power accommodation capability can be significantly improved. However, traditional plan tracking strategy of wind power and energy storage combined system usually makes decisions based on current operating conditions. Since the strategy does not consider the future regulation requirement, the energy storage system may be out of operation since the state of charge (SOC) is too high or too low. Aiming at the shortage of current tracking strategy, this paper proposes a smart tracking strategy of wind power and energy storage combined generation system based on three‐stage rolling optimisation, including day‐ahead, within‐day, and real time. The reserved capacity of energy storage station is determined according to the wind power ramping trend prediction method in day‐head stage. The low limit of energy storage station SOC is corrected according to ultra‐short time wind power prediction in within‐day stage. In real‐time stage, the energy storage system selectively participates in active power control of combined system according to the actual power deviation and SOC operating range. Simulation result shows that the proposed method can effectively improve the combined system generating capacity.
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1809-1813
Open AccessResearch on smart tracking strategy of wind power and energy storage combined generation system based on three‐stage rolling optimisation
Wind power consumption has become a bottleneck in the development of wind power. Based on the energy storage's redistribution ability of wind power in time scale, the utilisation efficiency of wind power accommodation capability can be significantly improved. However, traditional plan tracking strategy of wind power and energy storage combined system usually makes decisions based on current operating conditions. Since the strategy does not consider the future regulation requirement, the energy storage system may be out of operation since the state of charge (SOC) is too high or too low. Aiming at the shortage of current tracking strategy, this paper proposes a smart tracking strategy of wind power and energy storage combined generation system based on three‐stage rolling optimisation, including day‐ahead, within‐day, and real time. The reserved capacity of energy storage station is determined according to the wind power ramping trend prediction method in day‐head stage. The low limit of energy storage station SOC is corrected according to ultra‐short time wind power prediction in within‐day stage. In real‐time stage, the energy storage system selectively participates in active power control of combined system according to the actual power deviation and SOC operating range. Simulation result shows that the proposed method can effectively improve the combined system generating capacity.