Xuemei Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuemei Xu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Ke-Hui Sun
School of Physics and Electronics, Central South University, Changsha, China
3 shared publicationsKehui Sun
School of Physics and Electronics, Central South University, Changsha, China
3 shared publicationsYi-Peng Ding
School of Physics and Electronics, Central South University, Changsha, 410083, China
3 shared publicationsYipeng Ding
School of Physics and Electronics, Central South University, Changsha, China
3 shared publicationsJia-Feng Ding
School of Physics and Electronics, Central South University, Changsha, 410083, China
2 shared publicationsLin-Zi Yin
School of Physics and Electronics, Central South University, Changsha, 410083, China
2 shared publications
Latest Publications
- 1 January 2022
- Published by Springer Nature in Journal of Central South University
- Vol. 29 (1) , 146-156
High quality-performance by changing parameters of antenna array
- 1 January 2022
- Published by Springer Nature in Journal of Central South University
- Vol. 29 (1) , 146-156
High quality-performance by changing parameters of antenna array
- 1 June 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (6) , 064701
Stochastic resonance in a single-well potential and its application in rolling bearing fault diagnosis
In this paper, a single-well model based on the piecewise function and classical bistable stochastic resonance (CBSR) is proposed. The steady state probability density of particles and mean first passage time in the model are calculated. The output characteristics and performance of the proposed model are analyzed through numerical simulation. On the basis of CBSR and the proposed model, an adaptive system is established (ACSSR) to generate the highest gain of signal-to-noise ratio (SNRg). Finally, the effectiveness of ACSSR in weak signal detection is verified with both simulated and experimental input signals. The results indicate that the ACSSR could detect the defect signal correctly and improve the SNRg.
- 1 June 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (6) , 064701
Stochastic resonance in a single-well potential and its application in rolling bearing fault diagnosis
In this paper, a single-well model based on the piecewise function and classical bistable stochastic resonance (CBSR) is proposed. The steady state probability density of particles and mean first passage time in the model are calculated. The output characteristics and performance of the proposed model are analyzed through numerical simulation. On the basis of CBSR and the proposed model, an adaptive system is established (ACSSR) to generate the highest gain of signal-to-noise ratio (SNRg). Finally, the effectiveness of ACSSR in weak signal detection is verified with both simulated and experimental input signals. The results indicate that the ACSSR could detect the defect signal correctly and improve the SNRg.
- 1 May 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (5) , 050501
Asymmetric stochastic resonance under non-Gaussian colored noise and time-delayed feedback*
Based on adiabatic approximation theory, in this paper we study the asymmetric stochastic resonance system with time-delayed feedback driven by non-Gaussian colored noise. The analytical expressions of the mean first-passage time (MFPT) and output signal-to-noise ratio (SNR) are derived by using a path integral approach, unified colored-noise approximation (UCNA), and small delay approximation. The effects of time-delayed feedback and non-Gaussian colored noise on the output SNR are analyzed. Moreover, three types of asymmetric potential function characteristics are thoroughly discussed. And they are well-depth asymmetry (DASR), well-width asymmetry (WASR), and synchronous action of well-depth and well-width asymmetry (DWASR), respectively. The conclusion of this paper is that the time-delayed feedback can suppress SR, however, the non-Gaussian noise deviation parameter has the opposite effect. Moreover, the correlation time plays a significant role in improving SNR, and the SNR of asymmetric stochastic resonance is higher than that of symmetric stochastic resonance. Our experiments demonstrate that the appropriate parameters can make the asymmetric stochastic resonance perform better to detect weak signals than the symmetric stochastic resonance, in which no matter whether these signals have low frequency or high frequency, accompanied by strong or weak noise.
- 1 May 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (5) , 050501
Asymmetric stochastic resonance under non-Gaussian colored noise and time-delayed feedback*
Based on adiabatic approximation theory, in this paper we study the asymmetric stochastic resonance system with time-delayed feedback driven by non-Gaussian colored noise. The analytical expressions of the mean first-passage time (MFPT) and output signal-to-noise ratio (SNR) are derived by using a path integral approach, unified colored-noise approximation (UCNA), and small delay approximation. The effects of time-delayed feedback and non-Gaussian colored noise on the output SNR are analyzed. Moreover, three types of asymmetric potential function characteristics are thoroughly discussed. And they are well-depth asymmetry (DASR), well-width asymmetry (WASR), and synchronous action of well-depth and well-width asymmetry (DWASR), respectively. The conclusion of this paper is that the time-delayed feedback can suppress SR, however, the non-Gaussian noise deviation parameter has the opposite effect. Moreover, the correlation time plays a significant role in improving SNR, and the SNR of asymmetric stochastic resonance is higher than that of symmetric stochastic resonance. Our experiments demonstrate that the appropriate parameters can make the asymmetric stochastic resonance perform better to detect weak signals than the symmetric stochastic resonance, in which no matter whether these signals have low frequency or high frequency, accompanied by strong or weak noise.
- 1 April 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (4) , 040503
NovelWoods–Saxon stochastic resonance system for weak signal detection*
We propose a joint exponential function and Woods–Saxon stochastic resonance (EWSSR) model. Because change of a single parameter in the classical stochastic resonance model may cause a great change in the shape of the potential function, it is difficult to obtain the optimal output signal-to-noise ratio by adjusting one parameter. In the novel system, the influence of different parameters on the shape of the potential function has its own emphasis, making it easier for us to adjust the shape of the potential function. The system can obtain different widths of the potential well or barrier height by adjusting one of these parameters, so that the system can match different types of input signals adaptively. By adjusting the system parameters, the potential function model can be transformed between the bistable model and the monostable model. The potential function of EWSSR has richer shapes and geometric characteristics. The effects of parameters, such as the height of the barrier and the width of the potential well, on SNR are studied, and a set of relatively optimal parameters are determined. Moreover, the EWSSR model is compared with other classical stochastic resonance models. Numerical experiments show that the proposed EWSSR model has higher SNR and better noise immunity than other classical stochastic resonance models. Simultaneously, the EWSSR model is applied to the detection of actual bearing fault signals, and the detection effect is also superior to other models.
- 1 April 2020
- Published by IOP Publishing in Chinese Physics B
- Vol. 29 (4) , 040503
NovelWoods–Saxon stochastic resonance system for weak signal detection*
We propose a joint exponential function and Woods–Saxon stochastic resonance (EWSSR) model. Because change of a single parameter in the classical stochastic resonance model may cause a great change in the shape of the potential function, it is difficult to obtain the optimal output signal-to-noise ratio by adjusting one parameter. In the novel system, the influence of different parameters on the shape of the potential function has its own emphasis, making it easier for us to adjust the shape of the potential function. The system can obtain different widths of the potential well or barrier height by adjusting one of these parameters, so that the system can match different types of input signals adaptively. By adjusting the system parameters, the potential function model can be transformed between the bistable model and the monostable model. The potential function of EWSSR has richer shapes and geometric characteristics. The effects of parameters, such as the height of the barrier and the width of the potential well, on SNR are studied, and a set of relatively optimal parameters are determined. Moreover, the EWSSR model is compared with other classical stochastic resonance models. Numerical experiments show that the proposed EWSSR model has higher SNR and better noise immunity than other classical stochastic resonance models. Simultaneously, the EWSSR model is applied to the detection of actual bearing fault signals, and the detection effect is also superior to other models.
- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (13) , 5062-5069
A Multi-Target Detection Algorithm Using High-Order Differential Equation
Dual-frequency Doppler radar is a popular tool for moving target tracking, which can support a large range of civilian and military applications. In this paper, a human localization algorithm based on high order differential equation and Doppler processing is proposed to increase the accuracy of Doppler radar target localization. High order differential equation is first proposed to process the radar echo signal and extract the instantaneous frequencies (IFs) of multiple targets. Then based on the estimated IFs, the target localizations can be easily synthesized by the Doppler processing. Compared with the short-time Fourier transform algorithm and fractical Fourier transform algorithm, the proposed algorithm has high frequency estimation accuracy and can effectively separate the frequencies from multiple targets radar echo whether frequency ambigouous issue occurs or not. A series of experiments are carried out to demonstrate the performance of the proposed algorithm.
- 7 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (13) , 5062-5069
A Multi-Target Detection Algorithm Using High-Order Differential Equation
Dual-frequency Doppler radar is a popular tool for moving target tracking, which can support a large range of civilian and military applications. In this paper, a human localization algorithm based on high order differential equation and Doppler processing is proposed to increase the accuracy of Doppler radar target localization. High order differential equation is first proposed to process the radar echo signal and extract the instantaneous frequencies (IFs) of multiple targets. Then based on the estimated IFs, the target localizations can be easily synthesized by the Doppler processing. Compared with the short-time Fourier transform algorithm and fractical Fourier transform algorithm, the proposed algorithm has high frequency estimation accuracy and can effectively separate the frequencies from multiple targets radar echo whether frequency ambigouous issue occurs or not. A series of experiments are carried out to demonstrate the performance of the proposed algorithm.
- Open Access
- 18 September 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (10) , 105010
Sensing analysis based on fano resonance in arch bridge structure
An arch bridge structure, comprising of a semiring cavity resonator coupled with bus waveguide, has been investigated numerically and theoretically. Due to the interaction between broad continuum state and the narrow discrete state which originates from the semiring cavity and bus waveguide respectively, fano resonance can be accrued in transmission spectra which possess a sheer asymmetrical profile that can be adjusted by changing the parameters of the structure with the finite-difference time-domain (FDTD) method. A plasmonic nanosensor is devised based on fano resonance in a metal-insulator-metal (MIM) waveguide system, which has a sensitivity of 1500nm/RIU as well as a figure of merit (FOM) of 5500. Our findings can provide the guidance for fundermental research of nanosensor in highly integrated optical circuits.
- 18 September 2018
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 2 (10) , 105010
Open AccessSensing analysis based on fano resonance in arch bridge structure
An arch bridge structure, comprising of a semiring cavity resonator coupled with bus waveguide, has been investigated numerically and theoretically. Due to the interaction between broad continuum state and the narrow discrete state which originates from the semiring cavity and bus waveguide respectively, fano resonance can be accrued in transmission spectra which possess a sheer asymmetrical profile that can be adjusted by changing the parameters of the structure with the finite-difference time-domain (FDTD) method. A plasmonic nanosensor is devised based on fano resonance in a metal-insulator-metal (MIM) waveguide system, which has a sensitivity of 1500nm/RIU as well as a figure of merit (FOM) of 5500. Our findings can provide the guidance for fundermental research of nanosensor in highly integrated optical circuits.
- 27 June 2018
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 133 (6) , 239
Application of a memristor-based oscillator to weak signal detection
- 27 June 2018
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 133 (6) , 239
Application of a memristor-based oscillator to weak signal detection
- 1 March 2018
- Published by Elsevier in Optics Communications
- Vol. 410, 751-755
Plasmon-induced transparency in sensing application with semicircle cavity waveguide
- 1 March 2018
- Published by Elsevier in Optics Communications
- Vol. 410, 751-755
Plasmon-induced transparency in sensing application with semicircle cavity waveguide
- Open Access
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electronics
- Vol. 27 (1) , 140-149
Detection of Foreign Particles in Medical Solution Using Modified Affinity Propagation
A new detection method based on modified affinity propagation is proposed for detecting foreign particles in medical solution. The captured sequential images are used to generate moving trajectories of possible foreign particles. The external disturbances and background are almost removed by using a series of simple and effective image processing. The extracted potential targets, including foreign particles and possible residual noises, are partitioned into a number of valid clusters by modified affinity propagation clustering, in which the new similarity measure can better reflect the intrinsic link of linearstructured datasets and the temporal constraint enforces the temporal continuity of data points. The foreign particles can be easily recognized by analyzing the cluster structure according to the continuity and smoothness of moving targets trajectory. This algorithm combines modified affinity propagation method with the moving characteristics of different particles, and can achieve accurate partitions efficiently even though the clusters are badly adjacent. The experimental results indicate that the proposed algorithm can detect foreign particles effectively with high detection speed and accuracy.
- 1 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electronics
- Vol. 27 (1) , 140-149
Open AccessDetection of Foreign Particles in Medical Solution Using Modified Affinity Propagation
A new detection method based on modified affinity propagation is proposed for detecting foreign particles in medical solution. The captured sequential images are used to generate moving trajectories of possible foreign particles. The external disturbances and background are almost removed by using a series of simple and effective image processing. The extracted potential targets, including foreign particles and possible residual noises, are partitioned into a number of valid clusters by modified affinity propagation clustering, in which the new similarity measure can better reflect the intrinsic link of linearstructured datasets and the temporal constraint enforces the temporal continuity of data points. The foreign particles can be easily recognized by analyzing the cluster structure according to the continuity and smoothness of moving targets trajectory. This algorithm combines modified affinity propagation method with the moving characteristics of different particles, and can achieve accurate partitions efficiently even though the clusters are badly adjacent. The experimental results indicate that the proposed algorithm can detect foreign particles effectively with high detection speed and accuracy.
- 1 November 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (11) , 114202
Self-calibration wavelength modulation spectroscopy for acetylene detection based on tunable diode laser absorption spectroscopy
The expressions of the second harmonic (2f) signal are derived on the basis of absorption spectral and lock-in theories. A parametric study indicates that the phase shift between the intensity and wavelength modulation makes a great contribution to the 2f signal. A self-calibration wavelength modulation spectroscopy (WMS) method based on tunable diode laser absorption spectroscopy (TDLAS) is applied, combining the advantages of ambient pressure, temperature suppression, and phase-shift influences elimination. Species concentration is retrieved simultaneously from selected 2f signal pairs of measured and reference WMS-2f spectra. The absorption line of acetylene (C2H2) at 1530.36 nm near-infrared is selected to detect C2H2 concentrations in the range of 0–400 ppmv. System sensitivity, detection precision and limit are markedly improved, demonstrating that the self-calibration method has better detecting performance than the conventional WMS.
- 1 November 2016
- Published by IOP Publishing in Chinese Physics B
- Vol. 25 (11) , 114202
Self-calibration wavelength modulation spectroscopy for acetylene detection based on tunable diode laser absorption spectroscopy
The expressions of the second harmonic (2f) signal are derived on the basis of absorption spectral and lock-in theories. A parametric study indicates that the phase shift between the intensity and wavelength modulation makes a great contribution to the 2f signal. A self-calibration wavelength modulation spectroscopy (WMS) method based on tunable diode laser absorption spectroscopy (TDLAS) is applied, combining the advantages of ambient pressure, temperature suppression, and phase-shift influences elimination. Species concentration is retrieved simultaneously from selected 2f signal pairs of measured and reference WMS-2f spectra. The absorption line of acetylene (C2H2) at 1530.36 nm near-infrared is selected to detect C2H2 concentrations in the range of 0–400 ppmv. System sensitivity, detection precision and limit are markedly improved, demonstrating that the self-calibration method has better detecting performance than the conventional WMS.