Byungnam Ahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Byungnam Ahn has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Andrius Jurgilaitis
MAX IV Laboratory, Lund University, PO Box 118, SE-221 00 Lund, Sweden
5 shared publications - David Kroon
MAX IV Laboratory, Lund University, PO Box 118, SE-221 00 Lund, Sweden
5 shared publications - J. Carl Ekström
MAX IV Laboratory, Lund University, PO Box 118, SE-221 00 Lund, Sweden
3 shared publications - Jörgen Larsson
MAX IV Laboratory, Lund University, Lund, Sweden
3 shared publications A. E. Terry
MAX IV Laboratory, Lund University, PO Box 118, SE-221 00 Lund, Sweden
1 shared publicationA. Wirth
Max Planck Institute of Quantum Optics 3 , D-85748 Garching, Germany
1 shared publication
Latest Publications
- Open Access
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1567-1574
Ultrafast time-resolved small-angle X-ray scattering setup on the FemtoMAX beamline
The design and main characteristics of the ultrafast time-resolved small-angle X-ray scattering (TR-SAXS) setup on the FemtoMAX beamline at MAX IV are described. TR-SAXS experiments have successfully been performed in a transmission geometry investigating solid gold nanospheres sealed in a quartz capillary. The femtosecond laser pump and X-ray probe technique has been used to commission the setup and follow the dynamics in the laser-excited solid nanoparticles. This commissioning experiment on the FemtoMAX beamline has revealed picosecond thermal expansion dynamics in gold nanostructures. The results demonstrate the beamline's potential for probing ultrafast phenomena in condensed matter systems employing the SAXS technique. This method complements the available diffraction techniques on the FemtoMAX beamline and opens new capabilities for investigating light-induced structural dynamics in solid-state materials.
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1567-1574
Open AccessUltrafast time-resolved small-angle X-ray scattering setup on the FemtoMAX beamline
The design and main characteristics of the ultrafast time-resolved small-angle X-ray scattering (TR-SAXS) setup on the FemtoMAX beamline at MAX IV are described. TR-SAXS experiments have successfully been performed in a transmission geometry investigating solid gold nanospheres sealed in a quartz capillary. The femtosecond laser pump and X-ray probe technique has been used to commission the setup and follow the dynamics in the laser-excited solid nanoparticles. This commissioning experiment on the FemtoMAX beamline has revealed picosecond thermal expansion dynamics in gold nanostructures. The results demonstrate the beamline's potential for probing ultrafast phenomena in condensed matter systems employing the SAXS technique. This method complements the available diffraction techniques on the FemtoMAX beamline and opens new capabilities for investigating light-induced structural dynamics in solid-state materials.
- Open Access
- 27 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (17)
Experimental evidence of dominant ultrafast diffusive energy transport by hot electrons in Cu
When the dimensions of structures shrink to the order of the inelastic mean free path of the energy-carrying quasi-particles, the character of energy transport changes from diffusive to ballistic. However, the point of transition remains a matter of debate. Here, we leverage the fluence-dependent transport efficiency to distinguish ballistic and diffusive electron transport in an approach not relying on the transport velocity. We follow the energy that is rapidly transferred across Cu layers of different thicknesses via hot electrons from a photo-excited Pt layer into a buried Ni detection layer. In the Ni layer, the transported energy linearly relates to a rapid lattice expansion, which we probe via ultrafast x-ray diffraction. A nonlinear dependence of the Ni strain amplitude on the absorbed laser fluence indicates that the transport through Cu becomes more efficient with increasing fluence, which is inconsistent with a ballistic scenario but reproduced by a diffusive energy transport model. We already identify that for a Cu thickness of about 50 nm, i.e., about twice the electronic inelastic mean free path, diffusive electronic energy transport dominates the spatial energy distribution. Our experimental approach is generally applicable to distinguish diffusion from ballistic energy transport.
- 27 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (17)
Open AccessExperimental evidence of dominant ultrafast diffusive energy transport by hot electrons in Cu
When the dimensions of structures shrink to the order of the inelastic mean free path of the energy-carrying quasi-particles, the character of energy transport changes from diffusive to ballistic. However, the point of transition remains a matter of debate. Here, we leverage the fluence-dependent transport efficiency to distinguish ballistic and diffusive electron transport in an approach not relying on the transport velocity. We follow the energy that is rapidly transferred across Cu layers of different thicknesses via hot electrons from a photo-excited Pt layer into a buried Ni detection layer. In the Ni layer, the transported energy linearly relates to a rapid lattice expansion, which we probe via ultrafast x-ray diffraction. A nonlinear dependence of the Ni strain amplitude on the absorbed laser fluence indicates that the transport through Cu becomes more efficient with increasing fluence, which is inconsistent with a ballistic scenario but reproduced by a diffusive energy transport model. We already identify that for a Cu thickness of about 50 nm, i.e., about twice the electronic inelastic mean free path, diffusive electronic energy transport dominates the spatial energy distribution. Our experimental approach is generally applicable to distinguish diffusion from ballistic energy transport.
- Open Access
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
The time-resolved luminescence end station for studies of ultrafast relaxation processes under pulsed femtosecond X-rays at the FemtoMAX beamline
We present the time-resolved luminescence end station developed at the FemtoMAX beamline at the MAX IV Laboratory for the studies of ultrafast energy relaxation and emission properties. The instrument consists of a temperature-controlled vacuum chamber sample environment, in which the UV–visible luminescence is collected from the point of interaction of ultrashort x-ray pulses with luminescent material and directed to a monochromator equipped with an ultrafast MCP-PMT detector operating in a photon-counting mode. The instrumental response function of the setup, determined by the duration of x-ray pulses (50 fs), optical path, and fast MCP-PMT response, was measured to 32 ps (FWHM) within the spectral range of 200–700 nm. In this paper, we present the results obtained under different operational conditions on the basis of three well-known scintillating samples, demonstrating that this instrument development for the scintillator community has established the foundation for ultrafast luminescence studies at FemtoMAX.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Open AccessThe time-resolved luminescence end station for studies of ultrafast relaxation processes under pulsed femtosecond X-rays at the FemtoMAX beamline
We present the time-resolved luminescence end station developed at the FemtoMAX beamline at the MAX IV Laboratory for the studies of ultrafast energy relaxation and emission properties. The instrument consists of a temperature-controlled vacuum chamber sample environment, in which the UV–visible luminescence is collected from the point of interaction of ultrashort x-ray pulses with luminescent material and directed to a monochromator equipped with an ultrafast MCP-PMT detector operating in a photon-counting mode. The instrumental response function of the setup, determined by the duration of x-ray pulses (50 fs), optical path, and fast MCP-PMT response, was measured to 32 ps (FWHM) within the spectral range of 200–700 nm. In this paper, we present the results obtained under different operational conditions on the basis of three well-known scintillating samples, demonstrating that this instrument development for the scintillator community has established the foundation for ultrafast luminescence studies at FemtoMAX.
- Open Access
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 1052-1058
A cross-correlator-based timing tool for FemtoMAX
We report on the commissioning of an ultrafast timing diagnostic for measuring a time-offset signal between two different synchronized ultrashort light pulses. The method is based on sum-frequency generation in a nonlinear crystal. The setup is similar to an auto/cross-correlator setup. In this case, one of the beams is a relatively weak diagnostic beam of visible light from a bending magnet at FemtoMAX (106 photons pulse−1 in a 0.2 mm high and 5 mm wide beam) while the other is a relatively intense laser beam (200 µJ pulse−1) derived from the same laser that is used to pump the sample in pump/probe experiments. This enables online monitoring of the relative timing of a linear accelerator-based, short-pulse, hard X-ray source and a synchronized visible laser. We show that for a <50 fs full width at half-maximum (FWHM) light pulse from the accelerator and a 50 fs (FWHM) long laser pulse, we can determine the relative timing of the two pulses with an accuracy below 30 fs in a time interval of 4 ps. The advantages and limitations of the method are discussed.
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 1052-1058
Open AccessA cross-correlator-based timing tool for FemtoMAX
We report on the commissioning of an ultrafast timing diagnostic for measuring a time-offset signal between two different synchronized ultrashort light pulses. The method is based on sum-frequency generation in a nonlinear crystal. The setup is similar to an auto/cross-correlator setup. In this case, one of the beams is a relatively weak diagnostic beam of visible light from a bending magnet at FemtoMAX (106 photons pulse−1 in a 0.2 mm high and 5 mm wide beam) while the other is a relatively intense laser beam (200 µJ pulse−1) derived from the same laser that is used to pump the sample in pump/probe experiments. This enables online monitoring of the relative timing of a linear accelerator-based, short-pulse, hard X-ray source and a synchronized visible laser. We show that for a <50 fs full width at half-maximum (FWHM) light pulse from the accelerator and a 50 fs (FWHM) long laser pulse, we can determine the relative timing of the two pulses with an accuracy below 30 fs in a time interval of 4 ps. The advantages and limitations of the method are discussed.
- Open Access
- 4 April 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (3) , 779-791
Status and perspective of protein crystallography at the first multi-bend achromat based synchrotron MAX IV
The first multi-bend achromat based synchrotron MAX IV operates two protein crystallography beamlines, BioMAX and MicroMAX. BioMAX is designed as a versatile, stable, high-throughput beamline catering for most protein crystallography experiments. MicroMAX is a more ambitious beamline dedicated to serial crystallography including time-resolved experiments. Both beamlines exploit the special characteristics of fourth-generation beamlines provided by the 3 GeV ring of MAX IV. In addition, the fragment-based drug discovery platform, FragMAX, is hosted and, at the FemtoMAX beamline, protein diffraction experiments exploring ultrafast time resolution can be performed. A technical and operational overview of the different beamlines and the platform is given as well as an outlook for protein crystallography embedded in the wider possibilities that MAX IV offers to users in the life sciences.
- 4 April 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (3) , 779-791
Open AccessStatus and perspective of protein crystallography at the first multi-bend achromat based synchrotron MAX IV
The first multi-bend achromat based synchrotron MAX IV operates two protein crystallography beamlines, BioMAX and MicroMAX. BioMAX is designed as a versatile, stable, high-throughput beamline catering for most protein crystallography experiments. MicroMAX is a more ambitious beamline dedicated to serial crystallography including time-resolved experiments. Both beamlines exploit the special characteristics of fourth-generation beamlines provided by the 3 GeV ring of MAX IV. In addition, the fragment-based drug discovery platform, FragMAX, is hosted and, at the FemtoMAX beamline, protein diffraction experiments exploring ultrafast time resolution can be performed. A technical and operational overview of the different beamlines and the platform is given as well as an outlook for protein crystallography embedded in the wider possibilities that MAX IV offers to users in the life sciences.
- Open Access
- 7 February 2017
- Published by AIP Publishing in APL Photonics
- Vol. 2 (3) , 036104
Attosecond-controlled photoemission from metal nanowire tips in the few-electron regime
Metal nanotip photoemitters have proven to be versatile in fundamental nanoplasmonics research and applications, including, e.g., the generation of ultrafast electron pulses, the adiabatic focusing of plasmons, and as light-triggered electron sources for microscopy. Here, we report the generation of high energy photoelectrons (up to 160 eV) in photoemission from single-crystalline nanowire tips in few-cycle, 750-nm laser fields at peak intensities of (2-7.3) × 1012 W/cm2. Recording the carrier-envelope phase (CEP)-dependent photoemission from the nanowire tips allows us to identify rescattering contributions and also permits us to determine the high-energy cutoff of the electron spectra as a function of laser intensity. So far these types of experiments from metal nanotips have been limited to an emission regime with less than one electron per pulse. We detect up to 13 e/shot and given the limited detection efficiency, we expect up to a few ten times more electrons being emitted from the nanowire. Within the investigated intensity range, we find linear scaling of cutoff energies. The nonlinear scaling of electron count rates is consistent with tunneling photoemission occurring in the absence of significant charge interaction. The high electron energy gain is attributed to field-induced rescattering in the enhanced nanolocalized fields at the wires apex, where a strong CEP-modulation is indicative of the attosecond control of photoemission.
- 7 February 2017
- Published by AIP Publishing in APL Photonics
- Vol. 2 (3) , 036104
Open AccessAttosecond-controlled photoemission from metal nanowire tips in the few-electron regime
Metal nanotip photoemitters have proven to be versatile in fundamental nanoplasmonics research and applications, including, e.g., the generation of ultrafast electron pulses, the adiabatic focusing of plasmons, and as light-triggered electron sources for microscopy. Here, we report the generation of high energy photoelectrons (up to 160 eV) in photoemission from single-crystalline nanowire tips in few-cycle, 750-nm laser fields at peak intensities of (2-7.3) × 1012 W/cm2. Recording the carrier-envelope phase (CEP)-dependent photoemission from the nanowire tips allows us to identify rescattering contributions and also permits us to determine the high-energy cutoff of the electron spectra as a function of laser intensity. So far these types of experiments from metal nanotips have been limited to an emission regime with less than one electron per pulse. We detect up to 13 e/shot and given the limited detection efficiency, we expect up to a few ten times more electrons being emitted from the nanowire. Within the investigated intensity range, we find linear scaling of cutoff energies. The nonlinear scaling of electron count rates is consistent with tunneling photoemission occurring in the absence of significant charge interaction. The high electron energy gain is attributed to field-induced rescattering in the enhanced nanolocalized fields at the wires apex, where a strong CEP-modulation is indicative of the attosecond control of photoemission.