MMMalte Mechtenberg

Malte Mechtenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Malte Mechtenberg has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Axel Schneider

    Biomechatronics Group, Faculty of Engineering and Mathematics, University of Applied Sciences, Bielefeld, Germany

    3 shared publications
  • Hanno Gerd Meyer

    Affiliations Biomechatronics and Embedded Systems Group, Bielefeld University of Applied Sciences, Bielefeld, NRW, Germany, Institute of Mechatronics and Systems Dynamics, Bielefeld University of Applied Sciences, Bielefeld, NRW, Germany

    2 shared publications
  • Nils Grimmelsmann

    Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences, 33619 Bielefeld, Germany

    2 shared publications
  • David Leserri

    Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences, Interaktion 1, D-33619 Bielefeld, Germany

    1 shared publication
  • Hanno Gerd Meyer

    Affiliation Biomechatronics and Embedded Systems Group, Bielefeld University of Applied Sciences, Bielefeld, NRW, Germany

    1 shared publication
  • Nils Grimmelsmann

    Affiliation Biomechatronics and Embedded Systems Group, Bielefeld University of Applied Sciences, Bielefeld, NRW, Germany

    1 shared publication

Latest Publications

  • Open Access

    sEMG-based prediction of human forearm movements utilizing a biomechanical model based on individual anatomical/ physiological measures and a reduced set of optimization parameters

    by Nils Grimmelsmann, Malte Mechtenberg, Wolfram Schenck, Hanno Gerd Meyer, Axel Schneider

    For assistive devices such as active orthoses, exoskeletons or other close-to-body robotic-systems, the immediate prediction of biological limb movements based on biosignals in the respective control system can be used to enable intuitive operation also by untrained users e.g. in healthcare, rehabilitation or industrial scenarios. Surface electromyography (sEMG) signals from the muscles that drive the limbs can be measured before the actual movement occurs and, hence, can be used as source for predicting limb movements. The aim of this work was to create a model that can be adapted to a new user or movement scenario with little measurement and computing effort. Therefore, a biomechanical model is presented that predicts limb movements of the human forearm based on easy to measure sEMG signals of the main muscles involved in forearm actuation (lateral and long head of triceps and short and long head of biceps). The model has 42 internal parameters of which 37 were attributed to 8 individually measured physiological measures (location of acromion at the shoulder, medial/lateral epicondyles as well as olecranon at the elbow, and styloid processes of radius/ulna at the wrist; maximum muscle forces of biceps and triceps). The remaining 5 parameters are adapted to specific movement conditions in an optimization process. The model was tested in an experimental study with 31 subjects in which the prediction quality of the model was assessed. The quality of the movement prediction was evaluated by using the normalized mean absolute error (nMAE) for two arm postures (lower, upper), two load conditions (2 kg, 4 kg) and two movement velocities (slow, fast). For the resulting 8 experimental combinations the nMAE varied between nMAE = 0.16 and nMAE = 0.21 (lower numbers better). An additional quality score (QS) was introduced that allows direct comparison between different movements. This score ranged from QS = 0.25 to QS = 0.40 (higher numbers better) for the experimental combinations. The above formulated aim was achieved with good prediction quality by using only 8 individual measurements (easy to collect body dimensions) and the subsequent optimization of only 5 parameters. At the same time, just easily accessible sEMG measurement locations are used to enable simple integration, e.g. in exoskeletons. This biomechanical model does not compete with models that measure all sEMG signals of the muscle heads involved in order to achieve the highest possible prediction quality.


  • Open Access

    Manual and semi-automatic determination of elbow angle-independent parameters for a model of the biceps brachii distal tendon based on ultrasonic imaging

    by Malte Mechtenberg, Nils Grimmelsmann, Hanno Gerd Meyer, Axel Schneider

    Tendons consist of passive soft tissue with non linear material properties. They play a key role in force transmission from muscle to skeletal structure. The properties of tendons have been extensively examined in vitro. In this work, a non linear model of the distal biceps brachii tendon was parameterized based on measurements of myotendinous junction displacements in vivo at different load forces and elbow angles. The myotendinous junction displacement was extracted from ultrasound B-mode images within an experimental setup which also allowed for the retrieval of the exerted load forces as well as the elbow joint angles. To quantify the myotendinous junction movement based on visual features from ultrasound images, a manual and an automatic method were developed. The performance of both methods was compared. By means of exemplary data from three subjects, reliable fits of the tendon model were achieved. Further, different aspects of the non linear tendon model generated in this way could be reconciled with individual experiments from literature.


  • Open Access

    Evaluation of sEMG Signal Features and Segmentation Parameters for Limb Movement Prediction Using a Feedforward Neural Network

    by David Leserri, Nils Grimmelsmann, Malte Mechtenberg, Hanno Gerd Meyer, Axel Schneider

    Limb movement prediction based on surface electromyography (sEMG) for the control of wearable robots, such as active orthoses and exoskeletons, is a promising approach since it provides an intuitive control interface for the user. Further, sEMG signals contain early information about the onset and course of limb movements for feedback control. Recent studies have proposed machine learning-based modeling approaches for limb movement prediction using sEMG signals, which do not necessarily require domain knowledge of the underlying physiological system and its parameters. However, there is limited information on which features of the measured sEMG signals provide the best prediction accuracy of machine learning models trained with these data. In this work, the accuracy of elbow joint movement prediction based on sEMG data using a simple feedforward neural network after training with different single- and multi-feature sets and data segmentation parameters was compared. It was shown that certain combinations of time-domain and frequency-domain features, as well as segmentation parameters of sEMG data, improve the prediction accuracy of the neural network as compared to the use of a standard feature set from the literature.