Akihiro Fuchizaki
Research Subjects
Akihiro Fuchizaki has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Mitsunobu Tanaka
Japanese Red Cross Kinki Block Blood Center, Osaka, Japan
5 shared publications - Tomoya Hayashi
Japanese Red Cross Kinki Block Blood Center Osaka Japan
5 shared publications Kazushige Shimogaki
Japanese Red Cross Kinki Block Blood Center Osaka Japan
4 shared publications- Kazuta Yasui
Japanese Red Cross Kinki Block Blood Center Ibaraki Japan
4 shared publications Yoshihiro Takihara
Japanese Red Cross Kinki Block Blood Center Osaka Japan
4 shared publications- Fumiya Hirayama
Japanese Red Cross Kinki Block Blood Center Osaka Japan
3 shared publications
Latest Publications
- Open Access
Integrin β2 Plays a Significant Role in Therapeutic Angiogenesis Through Hematopoietic Stem Cell Transplantation
The efficacy of hematopoietic stem cell (HSC) therapy for cerebral infarction has been previously demonstrated. However, the lack of response in some patients has hindered its widespread use. To establish HSC therapy as a standard treatment, it is important to examine the causes of non-responsiveness. In this study, we aimed to identify the specifications of transplanted cells based on their therapeutic mechanisms to predict treatment success. We found that HSC therapy activates injured cerebral endothelial cells via gap junctions because cell adhesion between HSCs and the endothelium plays an essential role in cellular communication via gap junctions. The expression of the adhesion molecule integrin β2 (CD18) in CD34-positive (CD34+) cells was identified as critical for the therapeutic effect on cerebral infarction in a murine model. Cells with low CD18 expression exhibited a weaker therapeutic effect than cells with high CD18 expression, even when the same number of HSCs was administered. The expression of CD18 in CD34+ cells can be used as a specification marker for transplanted HSCs and is useful for identifying non-responders. Furthermore, quantification of CD18 expression is crucial for evaluating the cellular potential of cell-based therapies for diseases where therapeutic effects are mediated through cell adhesion.
Open AccessIntegrin β2 Plays a Significant Role in Therapeutic Angiogenesis Through Hematopoietic Stem Cell Transplantation
The efficacy of hematopoietic stem cell (HSC) therapy for cerebral infarction has been previously demonstrated. However, the lack of response in some patients has hindered its widespread use. To establish HSC therapy as a standard treatment, it is important to examine the causes of non-responsiveness. In this study, we aimed to identify the specifications of transplanted cells based on their therapeutic mechanisms to predict treatment success. We found that HSC therapy activates injured cerebral endothelial cells via gap junctions because cell adhesion between HSCs and the endothelium plays an essential role in cellular communication via gap junctions. The expression of the adhesion molecule integrin β2 (CD18) in CD34-positive (CD34+) cells was identified as critical for the therapeutic effect on cerebral infarction in a murine model. Cells with low CD18 expression exhibited a weaker therapeutic effect than cells with high CD18 expression, even when the same number of HSCs was administered. The expression of CD18 in CD34+ cells can be used as a specification marker for transplanted HSCs and is useful for identifying non-responders. Furthermore, quantification of CD18 expression is crucial for evaluating the cellular potential of cell-based therapies for diseases where therapeutic effects are mediated through cell adhesion.
- 1 July 2024
- Published by Wiley in Vox Sanguinis
- Vol. 119 (10) , 1065-1071
Quantification of the contribution of individual coagulation factors to haemostasis using a microchip flow chamber system and reconstituted blood from deficient plasma
Background and Objectives: Quantifying the contribution of individual coagulation factors to haemostasis may aid our understanding of the haemostatic function in patients with rare coagulation deficiencies (RCDs) and the exploration of suitable treatments.Materials and Methods: Reconstituted blood prepared from specific coagulation factor‐deficient plasma (factor [F]II; prothrombin, FV, FVII, FVIII, FIX, FX, FXI or FXII) and red blood cell/platelet products were used to simulate the whole blood of patients with RCD. We prepared in vitro treatment models for patients with prothrombin deficiency using coagulation factor agents and fresh frozen plasma. Haemostatic function was measured using a microchip flow chamber system at 600 s−1.Results: The haemostatic function was low, especially in blood samples reconstituted with prothrombin‐ and FX‐deficient plasma. In a plasma transfusion model of prothrombin deficiency, haemostatic function recovered after 10% replacement with normal plasma and reached a plateau at ≧60% replacement. A treatment model of prothrombin deficiency with prothrombin complex concentrates revealed dose‐dependent therapeutic effects in the range of 0–50 IU/kg.Conclusion: Microchip flow chamber system‐based quantification of haemostatic function using reconstituted blood could predict haemostasis and therapeutic effects of treatments in patients with prothrombin deficiency.
- 1 July 2024
- Published by Wiley in Vox Sanguinis
- Vol. 119 (10) , 1065-1071
Quantification of the contribution of individual coagulation factors to haemostasis using a microchip flow chamber system and reconstituted blood from deficient plasma
Background and Objectives: Quantifying the contribution of individual coagulation factors to haemostasis may aid our understanding of the haemostatic function in patients with rare coagulation deficiencies (RCDs) and the exploration of suitable treatments.Materials and Methods: Reconstituted blood prepared from specific coagulation factor‐deficient plasma (factor [F]II; prothrombin, FV, FVII, FVIII, FIX, FX, FXI or FXII) and red blood cell/platelet products were used to simulate the whole blood of patients with RCD. We prepared in vitro treatment models for patients with prothrombin deficiency using coagulation factor agents and fresh frozen plasma. Haemostatic function was measured using a microchip flow chamber system at 600 s−1.Results: The haemostatic function was low, especially in blood samples reconstituted with prothrombin‐ and FX‐deficient plasma. In a plasma transfusion model of prothrombin deficiency, haemostatic function recovered after 10% replacement with normal plasma and reached a plateau at ≧60% replacement. A treatment model of prothrombin deficiency with prothrombin complex concentrates revealed dose‐dependent therapeutic effects in the range of 0–50 IU/kg.Conclusion: Microchip flow chamber system‐based quantification of haemostatic function using reconstituted blood could predict haemostasis and therapeutic effects of treatments in patients with prothrombin deficiency.
- 2 March 2023
- Published by Wiley in Vox Sanguinis
- Vol. 118 (5) , 367-375
A novel quantitative method to evaluate the contribution of platelet products to white thrombus formation in reconstituted blood under flow conditions
Background and Objectives: Currently, the quality of platelet (PLT) products is evaluated using a series of in vitro tests, which only analyse PLTs as an inspection material. However, it would be ideal to assess the physiological functions of PLTs under conditions similar to the sequential blood haemostatic process. In this study, we attempted to establish an in vitro system where the thrombogenicity of PLT products was evaluated in the presence of red blood cells (RBCs) and plasma using a microchamber under constant shear stress (600/s).Materials and Methods: Blood samples were reconstituted by mixing PLT products, standard human plasma (SHP) and standard RBCs. Each component was serially diluted keeping the other two components fixed. The samples were applied onto a flow chamber system (Total Thrombus‐formation Analysis System [T‐TAS]), and white thrombus formation (WTF) was assessed under large arterial shear conditions.Results: We observed a good correlation between the PLT numbers in the test samples and WTF. The WTF of samples containing ≦10% SHP was significantly lower than those containing ≧40% SHP, and no difference was observed in WTF among samples containing 40%–100% SHP. WTF significantly declined in the absence of RBCs, whereas no change in WTF was observed in the presence of RBCs, over haematocrit range of 12.5%–50%.Conclusion: The WTF assessed on the T‐TAS using reconstituted blood may serve as a new physiological blood thrombus test to quantitatively determine the quality of PLT products.
- 2 March 2023
- Published by Wiley in Vox Sanguinis
- Vol. 118 (5) , 367-375
A novel quantitative method to evaluate the contribution of platelet products to white thrombus formation in reconstituted blood under flow conditions
Background and Objectives: Currently, the quality of platelet (PLT) products is evaluated using a series of in vitro tests, which only analyse PLTs as an inspection material. However, it would be ideal to assess the physiological functions of PLTs under conditions similar to the sequential blood haemostatic process. In this study, we attempted to establish an in vitro system where the thrombogenicity of PLT products was evaluated in the presence of red blood cells (RBCs) and plasma using a microchamber under constant shear stress (600/s).Materials and Methods: Blood samples were reconstituted by mixing PLT products, standard human plasma (SHP) and standard RBCs. Each component was serially diluted keeping the other two components fixed. The samples were applied onto a flow chamber system (Total Thrombus‐formation Analysis System [T‐TAS]), and white thrombus formation (WTF) was assessed under large arterial shear conditions.Results: We observed a good correlation between the PLT numbers in the test samples and WTF. The WTF of samples containing ≦10% SHP was significantly lower than those containing ≧40% SHP, and no difference was observed in WTF among samples containing 40%–100% SHP. WTF significantly declined in the absence of RBCs, whereas no change in WTF was observed in the presence of RBCs, over haematocrit range of 12.5%–50%.Conclusion: The WTF assessed on the T‐TAS using reconstituted blood may serve as a new physiological blood thrombus test to quantitatively determine the quality of PLT products.
- Top Cited PapersOpen Access
- 1 December 2022
- Published by American Society of Hematology in Blood
- Vol. 140 (22) , 2398-2402
iPLAT1: the first-in-human clinical trial of iPSC-derived platelets as a phase 1 autologous transfusion study
Refractoriness to platelet transfusion is a major problem in a small group of patients, and large-scale manufacturing of clinical grade functional platelets ex vivo has remained an elusive goal. Sugimoto et al report on the results of the first clinical trial of an autologous transfusion of induced pluripotent stem cell (iPSC)-derived platelets in a patient who had severe aplastic anemia but no compatible platelet donor. Using methodology described in a complementary article in Blood Advances, the results provide proof-of-principle and illustrate the challenges to be faced in taking this approach further.
- 1 December 2022
- Published by American Society of Hematology in Blood
- Vol. 140 (22) , 2398-2402
Top Cited PapersOpen AccessiPLAT1: the first-in-human clinical trial of iPSC-derived platelets as a phase 1 autologous transfusion study
Refractoriness to platelet transfusion is a major problem in a small group of patients, and large-scale manufacturing of clinical grade functional platelets ex vivo has remained an elusive goal. Sugimoto et al report on the results of the first clinical trial of an autologous transfusion of induced pluripotent stem cell (iPSC)-derived platelets in a patient who had severe aplastic anemia but no compatible platelet donor. Using methodology described in a complementary article in Blood Advances, the results provide proof-of-principle and illustrate the challenges to be faced in taking this approach further.
- Open Access
- 28 September 2022
- Published by American Society of Hematology in Blood Advances
- Vol. 6 (23) , 6056-6069
Production and nonclinical evaluation of an autologous iPSC–derived platelet product for the iPLAT1 clinical trial
Donor-derived platelets are used to treat or prevent hemorrhage in patients with thrombocytopenia. However, ∼5% or more of these patients are complicated with alloimmune platelet transfusion refractoriness (allo-PTR) due to alloantibodies against HLA-I or human platelet antigens (HPA). In these cases, platelets from compatible donors are necessary, but it is difficult to find such donors for patients with rare HLA-I or HPA. To produce platelet products for patients with aplastic anemia with allo-PTR due to rare HPA-1 mismatch in Japan, we developed an ex vivo good manufacturing process (GMP)–based production system for an induced pluripotent stem cell–derived platelet product (iPSC-PLTs). Immortalized megakaryocyte progenitor cell lines (imMKCLs) were established from patient iPSCs, and a competent imMKCL clone was selected for the master cell bank (MCB) and confirmed for safety, including negativity of pathogens. From this MCB, iPSC-PLTs were produced using turbulent flow bioreactors and new drugs. In extensive nonclinical studies, iPSC-PLTs were confirmed for quality, safety, and efficacy, including hemostasis in a rabbit model. This report presents a complete system for the GMP-based production of iPSC-PLTs and the required nonclinical studies and thus supports the iPLAT1 study, the first-in-human clinical trial of iPSC-PLTs in a patient with allo-PTR and no compatible donor using the autologous product. It also serves as a comprehensive reference for the development of widely applicable allogeneic iPSC-PLTs and other cell products that use iPSC-derived progenitor cells as MCB.
- 28 September 2022
- Published by American Society of Hematology in Blood Advances
- Vol. 6 (23) , 6056-6069
Open AccessProduction and nonclinical evaluation of an autologous iPSC–derived platelet product for the iPLAT1 clinical trial
Donor-derived platelets are used to treat or prevent hemorrhage in patients with thrombocytopenia. However, ∼5% or more of these patients are complicated with alloimmune platelet transfusion refractoriness (allo-PTR) due to alloantibodies against HLA-I or human platelet antigens (HPA). In these cases, platelets from compatible donors are necessary, but it is difficult to find such donors for patients with rare HLA-I or HPA. To produce platelet products for patients with aplastic anemia with allo-PTR due to rare HPA-1 mismatch in Japan, we developed an ex vivo good manufacturing process (GMP)–based production system for an induced pluripotent stem cell–derived platelet product (iPSC-PLTs). Immortalized megakaryocyte progenitor cell lines (imMKCLs) were established from patient iPSCs, and a competent imMKCL clone was selected for the master cell bank (MCB) and confirmed for safety, including negativity of pathogens. From this MCB, iPSC-PLTs were produced using turbulent flow bioreactors and new drugs. In extensive nonclinical studies, iPSC-PLTs were confirmed for quality, safety, and efficacy, including hemostasis in a rabbit model. This report presents a complete system for the GMP-based production of iPSC-PLTs and the required nonclinical studies and thus supports the iPLAT1 study, the first-in-human clinical trial of iPSC-PLTs in a patient with allo-PTR and no compatible donor using the autologous product. It also serves as a comprehensive reference for the development of widely applicable allogeneic iPSC-PLTs and other cell products that use iPSC-derived progenitor cells as MCB.
- 23 September 2022
- Published by Wiley in Transfusion
- Vol. 62 (11) , 2262-2270
Automated preparation of washed platelet concentrates through spinning‐membrane filtration
Background: Washed platelet concentrates (WPC), prepared with an automated system cell processor (ACP), have recently been approved to be manufactured and marketed in Japan. From the perspective of risk management, it is preferable to secure alternative technologies for ACP. Here, we conducted a study to evaluate the quality of WPC prepared using an automated membrane filtration‐based system, Lovo.Study design and methods: Replaced PCs prepared from apheresis PCs were equally divided into control and test units, and subsequently washed using ACP and Lovo respectively. Work and operational efficiencies were evaluated by in vitro analyses, including total handling time, platelet recovery, and plasma protein removal rate. Product quality, including a set of biochemical and physiological indicators of platelets and supernatants, were assessed before and 3 days after washing.Results: In vitro platelet recovery rates and plasma protein removal rates were >85% and >95%, respectively, in both groups. The pH values on day 0 were significantly high (6.97 vs. 6.86) due to low pCO2 in the test group, while no significant differences in glucose consumption and lactate production were observed between the two groups. The levels of hypotonic shock responses, aggregation response, platelet shape, CD62P expression, and sCD62P concentration were similar in both groups during the 3‐day storage period.Conclusion: Platelet washing with Lovo provides platelet quality equivalent to, or better than, conventional washing with ACP. Thus, the new automated system, Lovo, can be considered as an alternative to ACP for WPC preparation.
- 23 September 2022
- Published by Wiley in Transfusion
- Vol. 62 (11) , 2262-2270
Automated preparation of washed platelet concentrates through spinning‐membrane filtration
Background: Washed platelet concentrates (WPC), prepared with an automated system cell processor (ACP), have recently been approved to be manufactured and marketed in Japan. From the perspective of risk management, it is preferable to secure alternative technologies for ACP. Here, we conducted a study to evaluate the quality of WPC prepared using an automated membrane filtration‐based system, Lovo.Study design and methods: Replaced PCs prepared from apheresis PCs were equally divided into control and test units, and subsequently washed using ACP and Lovo respectively. Work and operational efficiencies were evaluated by in vitro analyses, including total handling time, platelet recovery, and plasma protein removal rate. Product quality, including a set of biochemical and physiological indicators of platelets and supernatants, were assessed before and 3 days after washing.Results: In vitro platelet recovery rates and plasma protein removal rates were >85% and >95%, respectively, in both groups. The pH values on day 0 were significantly high (6.97 vs. 6.86) due to low pCO2 in the test group, while no significant differences in glucose consumption and lactate production were observed between the two groups. The levels of hypotonic shock responses, aggregation response, platelet shape, CD62P expression, and sCD62P concentration were similar in both groups during the 3‐day storage period.Conclusion: Platelet washing with Lovo provides platelet quality equivalent to, or better than, conventional washing with ACP. Thus, the new automated system, Lovo, can be considered as an alternative to ACP for WPC preparation.
- 8 March 2022
- Published by Wiley in Vox Sanguinis
- Vol. 117 (6) , 812-821
Comparison of the programmed freezer method and deep freezer method in the manufacturing of frozen red blood cell products
Frozen-thawed red blood cells (FTRCs) are useful blood components to patients with rare blood phenotypes. However, frozen red blood cells (FRCs) sometimes cause significant haemolysis after thawing due to the freeze/thaw process. In this study, we aimed to focus on the former process and reduce process-related haemolysis. Five-day-old red blood cells (RBCs) (5D) or 9-week-old RBCs (9 W) were glycerolized, pooled and split into two aliquots. RBCs were frozen using either the programmed freezer (PF) method or the deep freezer (DF) method. After 4-8 weeks, the FRCs were thawed and washed. In vitro characteristics were compared between the PF and DF methods. Nine week were used as a starting material for FTRCs with the assumption that they can mimic disqualified FTRCs with respect to Hb recovery. The PF method resulted in a significantly higher Hb recovery rate than the DF method (5D: 85.9 ± 2.1 vs. 81.1% ± 3.5%, p < 0.001) (9 W: 56.8 ± 4.0 vs. 52.4% ± 3.5%, p < 0.001). Both 5D and 9W-derived FTRCs immediately after preparation prepared by the PF method were more resistible to haemolysis than those prepared by the DF method. On the other hand, there were no significant differences between PF and DF methods in Adenosine 5'-triphosphate (ATP) and 2,3-diphosphoglycerate (2,3-DPG). The PF method was more suitable for RBC freezing than the DF method in terms of Hb recovery in FTRCs. Although it was only 4%-5%, the improvement in the Hb recovery rate will contribute to a more stable supply.
- 8 March 2022
- Published by Wiley in Vox Sanguinis
- Vol. 117 (6) , 812-821
Comparison of the programmed freezer method and deep freezer method in the manufacturing of frozen red blood cell products
Frozen-thawed red blood cells (FTRCs) are useful blood components to patients with rare blood phenotypes. However, frozen red blood cells (FRCs) sometimes cause significant haemolysis after thawing due to the freeze/thaw process. In this study, we aimed to focus on the former process and reduce process-related haemolysis. Five-day-old red blood cells (RBCs) (5D) or 9-week-old RBCs (9 W) were glycerolized, pooled and split into two aliquots. RBCs were frozen using either the programmed freezer (PF) method or the deep freezer (DF) method. After 4-8 weeks, the FRCs were thawed and washed. In vitro characteristics were compared between the PF and DF methods. Nine week were used as a starting material for FTRCs with the assumption that they can mimic disqualified FTRCs with respect to Hb recovery. The PF method resulted in a significantly higher Hb recovery rate than the DF method (5D: 85.9 ± 2.1 vs. 81.1% ± 3.5%, p < 0.001) (9 W: 56.8 ± 4.0 vs. 52.4% ± 3.5%, p < 0.001). Both 5D and 9W-derived FTRCs immediately after preparation prepared by the PF method were more resistible to haemolysis than those prepared by the DF method. On the other hand, there were no significant differences between PF and DF methods in Adenosine 5'-triphosphate (ATP) and 2,3-diphosphoglycerate (2,3-DPG). The PF method was more suitable for RBC freezing than the DF method in terms of Hb recovery in FTRCs. Although it was only 4%-5%, the improvement in the Hb recovery rate will contribute to a more stable supply.