Yu Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yu Yao has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Zhigang Zhu
School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
8 shared publications Yutong Han
5 shared publicationsLili Xie
School of Energy and Materials, Shanghai Polytechnic University, Shanghai, 201209, China
3 shared publications- Yutong Han
School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China
3 shared publications Ziyang Yin
3 shared publicationsHaozhe Zhuang
2 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by Elsevier in SSRN Electronic Journal
MXene-Functionalized Aerogels for Stable Dual-Mode Humidity and Pressure Sensing toward Health Monitoring
Flexible multimodal sensors are crucial for continuous physiological and environmental monitoring in wearable devices and human–machine interaction. However, the synergistic optimization of multi-sensing performance and understanding the fundamental sensing mechanisms of multimodal sensors with the same sensitive materials remains a critical challenge. Herein, an MXene-functionalized polyvinyl alcohol/sodium alginate (PVA/SA) aerogel with a three-dimensional, dynamic, dual-network structure was developed as a stable dual-mode humidity and pressure sensing platform with distinct electrical outputs. PVA/SA aerogels provide an ideal foundation for dual-mode sensing with abundant hydrophilic groups for humidity sensing and a robust matrix for mechanical perception. The introduction of highly conductive, hydrophilic MXene synergistically enhances dual-mode sensing performance. The fabricated self-powered humidity sensor achieves a spontaneous voltage output of over 400 mV, a response time of 22 s, low humidity hysteresis, and stable sensing performance after two months of environmental storage. Simultaneously, the pressure sensor exhibits a wide response range and reliable fatigue resistance. Continuous cross-monitoring of sleep apnea is achieved by synergistically utilizing these humidity and pressure sensors. A smart insole integrating a pressure sensor array and employing a deep learning algorithm achieves accurate identification of five gait types. Ultimately, this work offers a stable dual-mode platform that provides an ideal option for future intelligent health monitoring and human–machine interaction.
- 16 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMXene-Functionalized Aerogels for Stable Dual-Mode Humidity and Pressure Sensing toward Health Monitoring
Flexible multimodal sensors are crucial for continuous physiological and environmental monitoring in wearable devices and human–machine interaction. However, the synergistic optimization of multi-sensing performance and understanding the fundamental sensing mechanisms of multimodal sensors with the same sensitive materials remains a critical challenge. Herein, an MXene-functionalized polyvinyl alcohol/sodium alginate (PVA/SA) aerogel with a three-dimensional, dynamic, dual-network structure was developed as a stable dual-mode humidity and pressure sensing platform with distinct electrical outputs. PVA/SA aerogels provide an ideal foundation for dual-mode sensing with abundant hydrophilic groups for humidity sensing and a robust matrix for mechanical perception. The introduction of highly conductive, hydrophilic MXene synergistically enhances dual-mode sensing performance. The fabricated self-powered humidity sensor achieves a spontaneous voltage output of over 400 mV, a response time of 22 s, low humidity hysteresis, and stable sensing performance after two months of environmental storage. Simultaneously, the pressure sensor exhibits a wide response range and reliable fatigue resistance. Continuous cross-monitoring of sleep apnea is achieved by synergistically utilizing these humidity and pressure sensors. A smart insole integrating a pressure sensor array and employing a deep learning algorithm achieves accurate identification of five gait types. Ultimately, this work offers a stable dual-mode platform that provides an ideal option for future intelligent health monitoring and human–machine interaction.
- 23 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (41) , 20996-21005
Highly sensitive detection of n -butanol at room temperature using a SnO 2 /Nb 4 C 3 T x -based sensing platform
Few-layer Nb 4 C 3 T x MXene nanosheets were prepared and tested for n -butanol sensing. The SnO 2 /Nb 4 C 3 T x nanocomposite was also synthesized, showing excellent n -butanol sensing performance at room temperature.
- 23 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (41) , 20996-21005
Highly sensitive detection of n -butanol at room temperature using a SnO 2 /Nb 4 C 3 T x -based sensing platform
Few-layer Nb 4 C 3 T x MXene nanosheets were prepared and tested for n -butanol sensing. The SnO 2 /Nb 4 C 3 T x nanocomposite was also synthesized, showing excellent n -butanol sensing performance at room temperature.
- 26 February 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 433
ZnS/Ti3C2Tx MXene nanocomposites based humidity sensor with improved sensing performance
- 26 February 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 433
ZnS/Ti3C2Tx MXene nanocomposites based humidity sensor with improved sensing performance
- 10 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 503
Transient MBene surpassing MXene for high-selectivity NH3 sensing in meat spoilage detection
- 10 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 503
Transient MBene surpassing MXene for high-selectivity NH3 sensing in meat spoilage detection
- 12 April 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 489
High-intensity ultrasonic exfoliation-assisted rapid preparation of MXene for gas sensing
- 12 April 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 489
High-intensity ultrasonic exfoliation-assisted rapid preparation of MXene for gas sensing
- 2 March 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (13) , 4809-4816
Fast response flexible humidity sensors based on Ti3C2Tx MXene-heterostructures for multifunctional applications
The designed Ti3C2Tx/SnO2 humidity sensors are endowed with rapid response time and excellent sensing performance, which also display the great potential for the applications of real-time respiratory monitoring and non-contact measurements.
- 2 March 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (13) , 4809-4816
Fast response flexible humidity sensors based on Ti3C2Tx MXene-heterostructures for multifunctional applications
The designed Ti3C2Tx/SnO2 humidity sensors are endowed with rapid response time and excellent sensing performance, which also display the great potential for the applications of real-time respiratory monitoring and non-contact measurements.
- 29 February 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (7) , 2016-2022
Rational design of NiO/Ti 3 C 2 T x nanocomposites with enhanced triethylamine sensing performance
The fabricated NiO/Ti 3 C 2 T x sensor exhibits a high response value of 950% to 50 ppm TEA with fast response/recovery times of 8/40 s.
- 29 February 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (7) , 2016-2022
Rational design of NiO/Ti 3 C 2 T x nanocomposites with enhanced triethylamine sensing performance
The fabricated NiO/Ti 3 C 2 T x sensor exhibits a high response value of 950% to 50 ppm TEA with fast response/recovery times of 8/40 s.
- 19 February 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 35 (19) , 195701
Preparation of a high-performance H2S gas sensor based on CuO/Co3O4 composite derived from bimetallic MOF
The bimetallic metal–organic frameworks (MOFs), Cu/Co-MOF, was synthesized through a solvothermal method and calcined to obtain CuO/Co3O4 composites. By adjusting the molar ratio between Cu and Co ions, a composite material of CuO/Co3O4 (Cu:Co = 1:1) was developed and showed excellent sensing capabilities, and the response reached as high as 196.3 for 10 ppm H2S detection. Furthermore, the optimal operating temperature as low as 40 °C was found. In comparison with the sensors prepared by pristine CuO and pristine Co3O4, the sensor based on CuO/Co3O4 composite exhibited a significant response. Additionally, the sensor can detect H2S gas down to 300 ppb. The gas sensing mechanism is discussed in depth from the perspective of p–p heterojunction formation between the p-type CuO and p-type Co3O4. The as-prepared CuO/Co3O4 composite-based sensor is expected to find practical application in the low-power monitoring of H2S.
- 19 February 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 35 (19) , 195701
Preparation of a high-performance H2S gas sensor based on CuO/Co3O4 composite derived from bimetallic MOF
The bimetallic metal–organic frameworks (MOFs), Cu/Co-MOF, was synthesized through a solvothermal method and calcined to obtain CuO/Co3O4 composites. By adjusting the molar ratio between Cu and Co ions, a composite material of CuO/Co3O4 (Cu:Co = 1:1) was developed and showed excellent sensing capabilities, and the response reached as high as 196.3 for 10 ppm H2S detection. Furthermore, the optimal operating temperature as low as 40 °C was found. In comparison with the sensors prepared by pristine CuO and pristine Co3O4, the sensor based on CuO/Co3O4 composite exhibited a significant response. Additionally, the sensor can detect H2S gas down to 300 ppb. The gas sensing mechanism is discussed in depth from the perspective of p–p heterojunction formation between the p-type CuO and p-type Co3O4. The as-prepared CuO/Co3O4 composite-based sensor is expected to find practical application in the low-power monitoring of H2S.
- 2 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 10 (15) , 8283-8292
MoO 3 /TiO 2 /Ti 3 C 2 T x nanocomposite based gas sensors for highly sensitive and selective isopropanol detection at room temperature
The MoO 3 /TiO 2 /Ti 3 C 2 T x composite was synthesized by a simple one-step hydrothermal method. Due to the formation of more active centers and heterojunctions, the sensor has excellent performance for VOCs and has a unique response to isopropanol.
- 2 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 10 (15) , 8283-8292
MoO 3 /TiO 2 /Ti 3 C 2 T x nanocomposite based gas sensors for highly sensitive and selective isopropanol detection at room temperature
The MoO 3 /TiO 2 /Ti 3 C 2 T x composite was synthesized by a simple one-step hydrothermal method. Due to the formation of more active centers and heterojunctions, the sensor has excellent performance for VOCs and has a unique response to isopropanol.