Yating Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yating Hu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hong Tang
School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China
4 shared publications - Miao Wang
School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China
3 shared publications - Binbin Guo
School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China
2 shared publications - Chengyu Liu
Southeast University
2 shared publications - Zehang Zhao
School of Biomedical Engineering, Dalian University of Technology, Dalian 116024, China
2 shared publications - Qing Liu
Department of Cardiology, the First Affiliated Hospital of Dalian Medical University, Dalian 116011, China
1 shared publication
Latest Publications
- Open Access
A Paralleled Multi-Task Learning-Based Framework for Single-Lead ECG Fine-Grained Noise Localization, Denoising and Signal Quality Assessment
Wearable ECG monitoring devices have become indispensable in personalized healthcare. However, dynamic signal acquisition during daily activities often introduces transient noise, which complicates signal classification and denoising, and may compromise diagnostic reliability. To address this challenge, this study proposes an ECG preprocessing framework based on multi-task learning, in which a fine-grained noise localization task is introduced to guide and assist both ECG signal quality assessment and denoising. Built upon a Transformer backbone and optimized with three task-specific loss functions, the proposed model leveraged weak supervision and pathological ECG data to learn robust noise-invariant representations. This design incorporates intra-class awareness, enabling the model to overcome various noise within the same quality category and to perform adaptive denoising beyond conventional inter-class-based approaches. Extensive experiments demonstrated state-of-the-art performance in both denoising and quality assessment, with weighted average F1-scores ranging from 95.72% to 98.49% and classification accuracy exceeding 95.68%. Moreover, under extremely severe noise conditions, the signal-to-noise ratio (SNR) is improved from −1.95 ± 3.83 dB to 12.20 ± 2.51 dB while preserving waveform fidelity. After pruning and quantization, the model could be effectively compressed, thereby enhancing its suitability for real-time deployment in edge computing scenarios. Overall, the proposed method not only preserved diagnostically important ECG waveforms and provided interpretable noise localization but also offers an efficient and clinically relevant solution for large-scale, real-time ECG monitoring.
Open AccessA Paralleled Multi-Task Learning-Based Framework for Single-Lead ECG Fine-Grained Noise Localization, Denoising and Signal Quality Assessment
Wearable ECG monitoring devices have become indispensable in personalized healthcare. However, dynamic signal acquisition during daily activities often introduces transient noise, which complicates signal classification and denoising, and may compromise diagnostic reliability. To address this challenge, this study proposes an ECG preprocessing framework based on multi-task learning, in which a fine-grained noise localization task is introduced to guide and assist both ECG signal quality assessment and denoising. Built upon a Transformer backbone and optimized with three task-specific loss functions, the proposed model leveraged weak supervision and pathological ECG data to learn robust noise-invariant representations. This design incorporates intra-class awareness, enabling the model to overcome various noise within the same quality category and to perform adaptive denoising beyond conventional inter-class-based approaches. Extensive experiments demonstrated state-of-the-art performance in both denoising and quality assessment, with weighted average F1-scores ranging from 95.72% to 98.49% and classification accuracy exceeding 95.68%. Moreover, under extremely severe noise conditions, the signal-to-noise ratio (SNR) is improved from −1.95 ± 3.83 dB to 12.20 ± 2.51 dB while preserving waveform fidelity. After pruning and quantization, the model could be effectively compressed, thereby enhancing its suitability for real-time deployment in edge computing scenarios. Overall, the proposed method not only preserved diagnostically important ECG waveforms and provided interpretable noise localization but also offers an efficient and clinically relevant solution for large-scale, real-time ECG monitoring.
- Open Access
- 12 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 820
Detection of Paroxysmal Atrial Fibrillation from Dynamic ECG Recordings Based on a Deep Learning Model
Background and Objectives: Atrial fibrillation (AF) is one of the most common arrhythmias clinically. Aging tends to increase the risk of AF, which also increases the burden of other comorbidities, including coronary artery disease (CAD), and even heart failure (HF). The precise detection of AF is a challenge due to its intermittence and unpredictability. A method for the accurate detection of AF is still needed. Methods: A deep learning model was used to detect atrial fibrillation. Here, a distinction was not made between AF and atrial flutter (AFL), both of which manifest as a similar pattern on an electrocardiogram (ECG). This method not only discriminated AF from normal rhythm of the heart, but also detected its onset and offset. The proposed model involved residual blocks and a Transformer encoder. Results and Conclusions: The data used for training were obtained from the CPSC2021 Challenge, and were collected using dynamic ECG devices. Tests on four public datasets validated the availability of the proposed method. The best performance for AF rhythm testing attained an accuracy of 98.67%, a sensitivity of 87.69%, and a specificity of 98.56%. In onset and offset detection, it obtained a sensitivity of 95.90% and 87.70%, respectively. The algorithm with a low FPR of 0.46% was able to reduce troubling false alarms. The model had a great capability to discriminate AF from normal rhythm and to detect its onset and offset. Noise stress tests were conducted after mixing three types of noise. We visualized the model’s features using a heatmap and illustrated its interpretability. The model focused directly on the crucial ECG waveform where showed obvious characteristics of AF.
- 12 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 820
Open AccessDetection of Paroxysmal Atrial Fibrillation from Dynamic ECG Recordings Based on a Deep Learning Model
Background and Objectives: Atrial fibrillation (AF) is one of the most common arrhythmias clinically. Aging tends to increase the risk of AF, which also increases the burden of other comorbidities, including coronary artery disease (CAD), and even heart failure (HF). The precise detection of AF is a challenge due to its intermittence and unpredictability. A method for the accurate detection of AF is still needed. Methods: A deep learning model was used to detect atrial fibrillation. Here, a distinction was not made between AF and atrial flutter (AFL), both of which manifest as a similar pattern on an electrocardiogram (ECG). This method not only discriminated AF from normal rhythm of the heart, but also detected its onset and offset. The proposed model involved residual blocks and a Transformer encoder. Results and Conclusions: The data used for training were obtained from the CPSC2021 Challenge, and were collected using dynamic ECG devices. Tests on four public datasets validated the availability of the proposed method. The best performance for AF rhythm testing attained an accuracy of 98.67%, a sensitivity of 87.69%, and a specificity of 98.56%. In onset and offset detection, it obtained a sensitivity of 95.90% and 87.70%, respectively. The algorithm with a low FPR of 0.46% was able to reduce troubling false alarms. The model had a great capability to discriminate AF from normal rhythm and to detect its onset and offset. Noise stress tests were conducted after mixing three types of noise. We visualized the model’s features using a heatmap and illustrated its interpretability. The model focused directly on the crucial ECG waveform where showed obvious characteristics of AF.
- Open Access
- 4 December 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (12) , 2011
Development of a Multi-Channel Wearable Heart Sound Visualization System
A multi-channel wearable heart sound visualization system based on novel heart sound sensors for imaging cardiac acoustic maps was developed and designed. The cardiac acoustic map could be used to detect cardiac vibration and heart sound propagation. The visualization system acquired 72 heart sound signals and one ECG signal simultaneously using 72 heart sound sensors placed on the chest surface and one ECG analog front end. The novel heart sound sensors had the advantages of high signal quality, small size, and high sensitivity. Butterworth filtering and wavelet transform were used to reduce noise in the signals. The cardiac acoustic map was obtained based on the cubic spline interpolation of the heart sound signals. The results showed the heart sound signals on the chest surface could be detected and visualized by this system. The variations of heart sounds were clearly displayed. This study provided a way to select optimal position for auscultation of heart sounds. The visualization system could provide a technology for investigating the propagation of heart sound in the thoracic cavity.
- 4 December 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (12) , 2011
Open AccessDevelopment of a Multi-Channel Wearable Heart Sound Visualization System
A multi-channel wearable heart sound visualization system based on novel heart sound sensors for imaging cardiac acoustic maps was developed and designed. The cardiac acoustic map could be used to detect cardiac vibration and heart sound propagation. The visualization system acquired 72 heart sound signals and one ECG signal simultaneously using 72 heart sound sensors placed on the chest surface and one ECG analog front end. The novel heart sound sensors had the advantages of high signal quality, small size, and high sensitivity. Butterworth filtering and wavelet transform were used to reduce noise in the signals. The cardiac acoustic map was obtained based on the cubic spline interpolation of the heart sound signals. The results showed the heart sound signals on the chest surface could be detected and visualized by this system. The variations of heart sounds were clearly displayed. This study provided a way to select optimal position for auscultation of heart sounds. The visualization system could provide a technology for investigating the propagation of heart sound in the thoracic cavity.
- Open Access
- 16 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (3) , 86
Transfer Learning Models for Detecting Six Categories of Phonocardiogram Recordings
Background and aims: Auscultation is a cheap and fundamental technique for detecting cardiovascular disease effectively. Doctors’ abilities in auscultation are varied. Sometimes, there may be cases of misdiagnosis, even when auscultation is performed by an experienced doctor. Hence, it is necessary to propose accurate computational tools to assist auscultation, especially in developing countries. Artificial intelligence technology can be an efficient diagnostic tool for detecting cardiovascular disease. This work proposed an automatic multiple classification method for cardiovascular disease detection by heart sound signals. Methods and results: In this work, a 1D heart sound signal is translated into its corresponding 3D spectrogram using continuous wavelet transform (CWT). In total, six classes of heart sound data are used in this experiment. We combine an open database (including five classes of heart sound data: aortic stenosis, mitral regurgitation, mitral stenosis, mitral valve prolapse and normal) with one class (pulmonary hypertension) of heart sound data collected by ourselves to perform the experiment. To make the method robust in a noisy environment, the background deformation technique is used before training. Then, 10 transfer learning networks (GoogleNet, SqueezeNet, DarkNet19, MobileNetv2, Inception-ResNetv2, DenseNet201, Inceptionv3, ResNet101, NasNet-Large, and Xception) are used for comparison. Furthermore, other models (LSTM and CNN) are also compared with our proposed algorithm. The experimental results show that four transfer learning networks (ResNet101, DenseNet201, DarkNet19 and GoogleNet) outperformed their peer models with an accuracy of 0.98 to detect the multiple heart diseases. The performances have been validated both in the original heart sound and the augmented heart sound using 10-fold cross validation. The results of these 10 folds are reported in this research. Conclusions: Our method obtained high classification accuracy even under a noisy background, which suggests that the proposed classification method could be used in auxiliary diagnosis for cardiovascular diseases.
- 16 March 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (3) , 86
Open AccessTransfer Learning Models for Detecting Six Categories of Phonocardiogram Recordings
Background and aims: Auscultation is a cheap and fundamental technique for detecting cardiovascular disease effectively. Doctors’ abilities in auscultation are varied. Sometimes, there may be cases of misdiagnosis, even when auscultation is performed by an experienced doctor. Hence, it is necessary to propose accurate computational tools to assist auscultation, especially in developing countries. Artificial intelligence technology can be an efficient diagnostic tool for detecting cardiovascular disease. This work proposed an automatic multiple classification method for cardiovascular disease detection by heart sound signals. Methods and results: In this work, a 1D heart sound signal is translated into its corresponding 3D spectrogram using continuous wavelet transform (CWT). In total, six classes of heart sound data are used in this experiment. We combine an open database (including five classes of heart sound data: aortic stenosis, mitral regurgitation, mitral stenosis, mitral valve prolapse and normal) with one class (pulmonary hypertension) of heart sound data collected by ourselves to perform the experiment. To make the method robust in a noisy environment, the background deformation technique is used before training. Then, 10 transfer learning networks (GoogleNet, SqueezeNet, DarkNet19, MobileNetv2, Inception-ResNetv2, DenseNet201, Inceptionv3, ResNet101, NasNet-Large, and Xception) are used for comparison. Furthermore, other models (LSTM and CNN) are also compared with our proposed algorithm. The experimental results show that four transfer learning networks (ResNet101, DenseNet201, DarkNet19 and GoogleNet) outperformed their peer models with an accuracy of 0.98 to detect the multiple heart diseases. The performances have been validated both in the original heart sound and the augmented heart sound using 10-fold cross validation. The results of these 10 folds are reported in this research. Conclusions: Our method obtained high classification accuracy even under a noisy background, which suggests that the proposed classification method could be used in auxiliary diagnosis for cardiovascular diseases.