YWYan Wang

Yan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yan Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High Round-Trip Gain Piezoelectric-Capacitive Hybrid Micromachined Ultrasonic Transducer Based on Anodic Bonding Technology

    by Yan Wang, Weijiang Xu, Ning Lv, Tao Wu, Jia Zhou, Junyan Ren

    In this work, a piezoelectric-capacitive hybrid micromachined ultrasonic transducer (HMUT) with a high round-trip gain was developed to achieve superior pulse-echo imaging performance. Initially, an equivalent circuit model (ECM) and a finite element model (FEM) were constructed to design and simulate the HMUT cell. A patterned etching technique for the piezoelectric layer was incorporated into the HMUT design. Simulation results indicated that the round-trip gain of the HMUT with patterned piezoelectric layer is 33 dB higher than that of the piezoelectric micromachined ultrasonic transducer (PMUT) and 3 dB higher than that of the capacitive micromachined ultrasonic transducer (CMUT). One of the innovative aspects of this technique is its ability to fabricate vertically stacked PMUT and CMUT. Based on anodic bonding technology, prototypes of 3 MHz PMUT, CMUT, and HMUT were fabricated on the same substrate. Finally, an electric impedance test and pulse-echo test were conducted. Experimental data confirmed that the HMUT exhibits higher round-trip gain, consistent with the simulation results. The successful fabrication of these prototypes demonstrates the feasibility of integrating multiple ultrasonic transducers on a single platform, enhancing the device’s compactness and versatility. Furthermore, it opens new avenues for the development of high-quality ultrasonic imaging.


  • Analysis, modeling and design of piezoelectric-capacitive hybrid micromachined ultrasonic transducer

    by Yan Wang, Ning Lv, Leming He, Junyan Ren

    This paper proposes a spring-mass-damper model for a piezoelectric-capacitive hybrid micromechanical ultrasonic transducer (HMUT) in immersion. Based on this model, a dual-force actuation mode is identified, where piezoelectric micromachined ultrasonic transducer (PMUT) and capacitive micromachined ultrasonic transducer (CMUT) are strongly coupled to achieve enhanced sensitivity. In order to design HMUT efficiently, an electro-mechanical-acoustical equivalent circuit model (ECM) is constructed and then the round-trip gain is calculated to demonstrate its pulse-echo response. The ECM calculations results align with those of finite element model simulations, showing a relative deviation less than 4%. In the design cases, the transmit sensitivity of HMUT is twice that of PMUT and more than five times that of CMUT. The receive sensitivity of HMUT is 1% lower than that of CMUT, but an order of magnitude larger than that of PMUT. The round-trip gain of the HMUT is at least 24.9 dB higher than that of PMUT and 14.1 dB higher than that of CMUT. These results demonstrate the potential of HMUT in surpassing bulk piezoelectric ultrasonic transducers in pulse-echo imaging. Furthermore, the impact of cell pitch on the pulse-echo response of HMUT arrays is characterize.


  • Low-Noise Low-Power Ultrasound AFE With Continuous TGC Built in Both TIA and Beamformer

    by Xinwei Yu, Yan Wang, Fan Ye, Junyan Ren

    This paper presents a low-noise high-power-efficiency analog front-end (AFE) for capacitive-micromachined-ultrasonic transducers (CMUT). Implemented in 28-nm CMOS technology, the proposed AFE features three-stage continuous time-gain compensation (TGC) embedded in both trans-impedance amplifiers (TIAs) and an analog beamformer to provide a large compensation range with no extra power-consumption cost. The use of noise cancellation and capacitive feedback optimizes the noise performance of TIAs. The first stage of the TGC is built in the TIA by adjusting the positive and negative resistance loads, which are composed of voltage-controlled transistor arrays. An all-pass passive network is used as the delay unit of the analog beamformer, meanwhile achieving the second TGC stage. Phase shift for all frequency components in the ultrasound pass-band is manifested as a delay to the echoes. The third stage of the TGC is merged with a summing unit, which is a closed-loop amplifier with variable resistance feedback. The design takes into account the ability to handle large signals and power consumption, with TIA and beamforming operating at voltages of 2.5 V and 0.9 V, respectively. Experimental results show that the proposed AFE achieves a 2.11 pA/√Hz input-referred noise (IRN) at the 5 MHz center frequency of the echoes while consuming only 1.02 mW/channel. A total exponential TGC range of 60 dB with continuous ranges of 12 dB, 24 dB, and 24 dB assigned to three stages has been verified for this work.


  • Open Access

    Sensitivity—Bandwidth Optimization of PMUT with Acoustical Matching Using Finite Element Method

    by Le-Ming He, Wei-Jiang Xu, Yan Wang, Jia Zhou, Jun-Yan Ren

    A new model in finite element method to study round-trip performance of piezoelectric micromachined ultrasonic transducers (pMUTs) is established. Most studies on the performance of pMUT are based only on the transmission sensibility, but the reception capacity is as much important as the transmission one, and is quite different from this latter. In this work, the round-trip sensitivity of pMUT is defined as the product of the frequency response of transmitted far field pressure to source voltage excitation and that of reception output to return wave pressure. Based on this sensitivity characteristic, firstly, a multi-parameter optimization for a cavity pMUT is performed using the sensitivity-bandwidth product parameter SBW as criterion. The radii of the electrode and the piezoelectric layer, the thicknesses of the piezoelectric layer and the vibration diaphragm are adjusted to maximize the performance. Secondly, an acoustic matching method is proposed and applied to pMUTs for the first time. As a result, the round-trip sensitivity can be evaluated and the pulse-echo response of wide-band excitation can be simulated, giving the most quantitative and intuitive feedback for pMUT design. The optimization enhances the sensitivity-bandwidth product by 52% when the top electrode and piezoelectric layer are both etched to 75% radius of the cavity beneath; the introduction of an acoustic matching layer shows significant bandwidth expansion in both the transmitting and receiving process.