XWXuemin Wang

Xuemin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuemin Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Doudou Zheng

    Taiyuan Institute of Technology

    1 shared publication
  • Hao Guo

    State Key Laboratory of Dynamic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan, China

    1 shared publication
  • Jun Liu

    State Key Laboratory of Dynamic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan, China

    1 shared publication
  • Jun Tang

    State Key Laboratory of Dynamic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan, China

    1 shared publication
  • Junzhi Zhao

    State Key Laboratory of Dynamic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan, China

    1 shared publication
  • Li Qin

    State Key Laboratory of Dynamic Measurement Technology, School of Instrument and Electronics, North University of China, Taiyuan, China

    1 shared publication

Latest Publications

  • Portable Diamond NV Magnetometer Head Integrated With 520 nm Diode Laser

    by Xuemin Wang, Doudou Zheng, Xiaocheng Wang, Xinyu Liu, Qimeng Wang, Junzhi Zhao, Hao Guo, Li Qin, Jun Tang, Zongmin Ma, et al.

    The integrated diamond nitrogen vacancy (NV) magnetometer has attracted considerable attention in recent years and presents high potential for its use in magnetic field detection in fields such as aerospace, medical, and agriculture. A laser with a large volume seriously hampers the integration and performance of magnetometers. To solve this problem, we proposed a 520-nm laser diode with an integrated NV magnetometer. The 520-nm laser diode has a high excitation efficiency and good performance with a small size. We introduced the key steps of designing an integrated magnetometer head and tested the performance, a magnetic field sensitivity of $20.77\,\,{n}T\,\,\cdot \,\,Hz^{-1/2}$ , and a shot noise sensitivity of $1.43\,\,{n}T\,\,\cdot \,\,Hz^{-1/2}$ . The measurable magnetic field range is from −107 to $107 ~\mu \text{T}$ , the system bandwidth is 15 Hz at the laser power of 10 mW, and the magnetic field conversion coefficient is 16.88 V/T. Thus, this paper provides a new method to minimise the light source volume and integrate it with a NV magnetometer.