Xiaohua Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaohua Huang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Carolina Mora Lopez
IMEC
4 shared publications - Chris Van Hoof
IMEC, Leuven, Belgium
3 shared publications - Georges Gielen
ESAT-MICAS, KU Leuven, Leuven, Flemish Brabant, Belgium
3 shared publications - Marco Ballini
IMEC, Leuven, Belgium
3 shared publications - Horacio Londoño Ramírez
Institute of Electrical and Micro Engineering and the Neuro-X Institute, Ecole Polytechnique Federale de Lausanne, Geneva, Switzerland
2 shared publications - Jan Genoe
IMEC, Leuven, Belgium
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (10) , 5746-5760
A 3072:96 Multiplexed Neural Readout IC With Two-Step Incremental-SAR Conversion and Efficient Bulk-DAC-Based Offset Compensation
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (10) , 5746-5760
A 3072:96 Multiplexed Neural Readout IC With Two-Step Incremental-SAR Conversion and Efficient Bulk-DAC-Based Offset Compensation
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (4) , 1538-1550
A Bidirectional Neuromodulation Chipset With Algorithm-Aware AFE Optimization and High-Voltage-Compliant Stimulation
This work presents a bidirectional neuromodulation chipset with 64-channel neural analog front-end (AFE), and a four-channel current stimulator. The chipset employs a heterogeneous architecture, combining a 28-nm low-voltage (LV) CMOS process for the AFE and the digital backend (DBE) to improve area and power efficiency, with a 180-nm high-voltage (HV) bipolar-CMOS-DMOS (BCD) process for the stimulation driver to achieve HV compliance. An AFE–DBE co-design framework is proposed to relax AFE noise requirements without sacrificing classification performance in the DBE, thus enabling significant reductions in AFE’s area and power consumption. In addition, we introduce a novel embedded current-steering digital-to-analog converter (IDAC) structure that addresses key limitations of conventional IDACs in multichannel direct-digitization recording architectures, including noise degradation from IDAC switching, and channel-to-channel gain variations. Overall, the proposed chipset achieves HV compliance (10 V) in the stimulator, while maintaining exceptional area and power efficiency in the AFE and DBE. Notably, the AFE achieves the smallest per-channel area (0.0009 mm2) and the lowest per-channel power (204 nW) reported to date for electrocorticography (ECoG) acquisition ( ${\leq }1$ kHz bandwidth). Together, these results highlight the chipset’s potential for implantable neuromodulation systems that enable long-term monitoring of neurological disorders with closed-loop intervention.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (4) , 1538-1550
A Bidirectional Neuromodulation Chipset With Algorithm-Aware AFE Optimization and High-Voltage-Compliant Stimulation
This work presents a bidirectional neuromodulation chipset with 64-channel neural analog front-end (AFE), and a four-channel current stimulator. The chipset employs a heterogeneous architecture, combining a 28-nm low-voltage (LV) CMOS process for the AFE and the digital backend (DBE) to improve area and power efficiency, with a 180-nm high-voltage (HV) bipolar-CMOS-DMOS (BCD) process for the stimulation driver to achieve HV compliance. An AFE–DBE co-design framework is proposed to relax AFE noise requirements without sacrificing classification performance in the DBE, thus enabling significant reductions in AFE’s area and power consumption. In addition, we introduce a novel embedded current-steering digital-to-analog converter (IDAC) structure that addresses key limitations of conventional IDACs in multichannel direct-digitization recording architectures, including noise degradation from IDAC switching, and channel-to-channel gain variations. Overall, the proposed chipset achieves HV compliance (10 V) in the stimulator, while maintaining exceptional area and power efficiency in the AFE and DBE. Notably, the AFE achieves the smallest per-channel area (0.0009 mm2) and the lowest per-channel power (204 nW) reported to date for electrocorticography (ECoG) acquisition ( ${\leq }1$ kHz bandwidth). Together, these results highlight the chipset’s potential for implantable neuromodulation systems that enable long-term monitoring of neurological disorders with closed-loop intervention.
- Open Access
- 25 December 2023
- Published by Wiley in Advanced Science
- Vol. 11 (10) , e2308507
Multiplexed Surface Electrode Arrays Based on Metal Oxide Thin‐Film Electronics for High‐Resolution Cortical Mapping
Electrode grids are used in neuroscience research and clinical practice to record electrical activity from the surface of the brain. However, existing passive electrocorticography (ECoG) technologies are unable to offer both high spatial resolution and wide cortical coverage, while ensuring a compact acquisition system. The electrode count and density are restricted by the fact that each electrode must be individually wired. This work presents an active micro‐electrocorticography (µECoG) implant that tackles this limitation by incorporating metal oxide thin‐film transistors (TFTs) into a flexible electrode array, allowing to address multiple electrodes through a single shared readout line. By combining the array with an incremental‐ΔΣ readout integrated circuit (ROIC), the system is capable of recording from up to 256 electrodes virtually simultaneously, thanks to the implemented 16:1 time‐division multiplexing scheme, offering lower noise levels than existing active µECoG arrays. In vivo validation is demonstrated acutely in mice by recording spontaneous activity and somatosensory evoked potentials over a cortical surface of ≈8×8 mm2. The proposed neural interface overcomes the wiring bottleneck limiting ECoG arrays, holding promise as a powerful tool for improved mapping of the cerebral cortex and as an enabling technology for future brain‐machine interfaces.
- 25 December 2023
- Published by Wiley in Advanced Science
- Vol. 11 (10) , e2308507
Open AccessMultiplexed Surface Electrode Arrays Based on Metal Oxide Thin‐Film Electronics for High‐Resolution Cortical Mapping
Electrode grids are used in neuroscience research and clinical practice to record electrical activity from the surface of the brain. However, existing passive electrocorticography (ECoG) technologies are unable to offer both high spatial resolution and wide cortical coverage, while ensuring a compact acquisition system. The electrode count and density are restricted by the fact that each electrode must be individually wired. This work presents an active micro‐electrocorticography (µECoG) implant that tackles this limitation by incorporating metal oxide thin‐film transistors (TFTs) into a flexible electrode array, allowing to address multiple electrodes through a single shared readout line. By combining the array with an incremental‐ΔΣ readout integrated circuit (ROIC), the system is capable of recording from up to 256 electrodes virtually simultaneously, thanks to the implemented 16:1 time‐division multiplexing scheme, offering lower noise levels than existing active µECoG arrays. In vivo validation is demonstrated acutely in mice by recording spontaneous activity and somatosensory evoked potentials over a cortical surface of ≈8×8 mm2. The proposed neural interface overcomes the wiring bottleneck limiting ECoG arrays, holding promise as a powerful tool for improved mapping of the cerebral cortex and as an enabling technology for future brain‐machine interfaces.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (11) , 3312-3323
Actively Multiplexed μECoG Brain Implant System With Incremental-ΔΣ ADCs Employing Bulk-DACs
Fundamental neuroscience research and high-performance neuro-prostheses require large-scale brain interfaces with ever-greater spatial resolution across a large cortex coverage, which cannot be achieved with current passive (micro) electrocorticography (ECoG) technologies. In this article, we present an active micro-electrocorticography ( $\mu$ ECoG) implant system that circumvents these challenges while achieving significantly lower noise compared to other existing active $\mu$ ECoG arrays. The proposed brain implant system is composed of a flexible, actively multiplexed 256-electrode $\mu$ ECoG array and an incremental- $\Delta \Sigma$ readout integrated circuit (ROIC). The 1 cm $\times$ 1 cm $\mu$ ECoG array was fabricated in a 3- $\mu$ m IGZO thin-film transistor (TFT) technology on a 15- $\mu$ m flexible foil and coupled to a 1.25 mm $\times$ 1.25 mm CMOS ROIC fabricated in a 22-nm fully depleted silicon on insulator (FDSOI) process. Due to the 256:16 time-division multiplexing achieved in the electrode array, only 16 multiplexed channels are required in the ROIC to acquire signals from the 256 electrodes simultaneously. By combining TFT multiplexing with newly proposed bulk-DAC (BDAC) feedback in the readout channel, we can integrate and address 4 $\times$ more electrodes than other passive arrays, achieve $>$ 10 $\times$ less noise than existing active arrays, and obtain $>$ 2 $\times$ effective channel area reduction in the ROIC while maintaining comparable electrical performance over current state-of-the-art ( $\mu$ )ECoG readouts.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (11) , 3312-3323
Actively Multiplexed μECoG Brain Implant System With Incremental-ΔΣ ADCs Employing Bulk-DACs
Fundamental neuroscience research and high-performance neuro-prostheses require large-scale brain interfaces with ever-greater spatial resolution across a large cortex coverage, which cannot be achieved with current passive (micro) electrocorticography (ECoG) technologies. In this article, we present an active micro-electrocorticography ( $\mu$ ECoG) implant system that circumvents these challenges while achieving significantly lower noise compared to other existing active $\mu$ ECoG arrays. The proposed brain implant system is composed of a flexible, actively multiplexed 256-electrode $\mu$ ECoG array and an incremental- $\Delta \Sigma$ readout integrated circuit (ROIC). The 1 cm $\times$ 1 cm $\mu$ ECoG array was fabricated in a 3- $\mu$ m IGZO thin-film transistor (TFT) technology on a 15- $\mu$ m flexible foil and coupled to a 1.25 mm $\times$ 1.25 mm CMOS ROIC fabricated in a 22-nm fully depleted silicon on insulator (FDSOI) process. Due to the 256:16 time-division multiplexing achieved in the electrode array, only 16 multiplexed channels are required in the ROIC to acquire signals from the 256 electrodes simultaneously. By combining TFT multiplexing with newly proposed bulk-DAC (BDAC) feedback in the readout channel, we can integrate and address 4 $\times$ more electrodes than other passive arrays, achieve $>$ 10 $\times$ less noise than existing active arrays, and obtain $>$ 2 $\times$ effective channel area reduction in the ROIC while maintaining comparable electrical performance over current state-of-the-art ( $\mu$ )ECoG readouts.
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 804-808
A Compact, Low-Power Analog Front-End With Event-Driven Input Biasing for High-Density Neural Recording in 22-nm FDSOI
An ultra-small-area, low-power analog front-end (AFE) for high-density neural recording is presented in this paper. It features an 11-bit incremental delta-sigma analog-to-digital converter (σ ADC) enhanced with an offset-rejecting event-driven input biasing network. This network avoids saturation of the ADC input caused by leakage of the input-coupling capacitor implemented in an advanced technology node. Combining AC-coupling with direct data conversion, the proposed AFE can tolerate a rail-to-rail electrode offset and achieves a good trade-off between power, noise, bandwidth, input impedance, and area. Fabricated in a 22-nm fully-depleted silicon on insulator (FDSOI) process, the design occupies an active area of <0.001 mm2, the smallest obtained to this date for a neural AFE, and consumes <3 μW from a 0.8-V supply. It achieves an input-referred noise of 11.3 μVrms in the action potential band (300 Hz -10 kHz) and 10 μVrms in the local field potential band (1 Hz -300 Hz).
- 9 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 804-808
A Compact, Low-Power Analog Front-End With Event-Driven Input Biasing for High-Density Neural Recording in 22-nm FDSOI
An ultra-small-area, low-power analog front-end (AFE) for high-density neural recording is presented in this paper. It features an 11-bit incremental delta-sigma analog-to-digital converter (σ ADC) enhanced with an offset-rejecting event-driven input biasing network. This network avoids saturation of the ADC input caused by leakage of the input-coupling capacitor implemented in an advanced technology node. Combining AC-coupling with direct data conversion, the proposed AFE can tolerate a rail-to-rail electrode offset and achieves a good trade-off between power, noise, bandwidth, input impedance, and area. Fabricated in a 22-nm fully-depleted silicon on insulator (FDSOI) process, the design occupies an active area of <0.001 mm2, the smallest obtained to this date for a neural AFE, and consumes <3 μW from a 0.8-V supply. It achieves an input-referred noise of 11.3 μVrms in the action potential band (300 Hz -10 kHz) and 10 μVrms in the local field potential band (1 Hz -300 Hz).
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 5.4GHz ΔΣ Bang-Bang PLL with 19dB In-Band Noise Reduction by Using a Nested PLL Filter
This paper presents an in-band noise reduction method for $\Delta \Sigma$ fractional-N bang-bang phase locked loops (BBPLLs) by using a nested integer-N BBPLL in the feedback path that works as a phase-domain low-pass filter (PDLPF). A prototype 5.4GHz $\Delta \Sigma$ fractional-N BBPLL is implemented in 65nm CMOS. The proposed $\Delta \Sigma$ fractional-N BBPLL achieves the in-band noise reduction of 19dB when the PDLPF is enabled. Experimental results show that the PDLPF method is useful for the $\Delta \Sigma$ fractional-N BBPLL not only to suppress the out-of-band noise but also to mitigate the in-band noise degradation.- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 5.4GHz ΔΣ Bang-Bang PLL with 19dB In-Band Noise Reduction by Using a Nested PLL Filter
This paper presents an in-band noise reduction method for $\Delta \Sigma$ fractional-N bang-bang phase locked loops (BBPLLs) by using a nested integer-N BBPLL in the feedback path that works as a phase-domain low-pass filter (PDLPF). A prototype 5.4GHz $\Delta \Sigma$ fractional-N BBPLL is implemented in 65nm CMOS. The proposed $\Delta \Sigma$ fractional-N BBPLL achieves the in-band noise reduction of 19dB when the PDLPF is enabled. Experimental results show that the PDLPF method is useful for the $\Delta \Sigma$ fractional-N BBPLL not only to suppress the out-of-band noise but also to mitigate the in-band noise degradation.