Yun-Sheng Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yun-Sheng Chan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chen-Yi Lee
Institute of Electronics, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
3 shared publications - Donglu Shi
Materials Science and Engineering Program, Department of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publication Hsu-Min Wu
Department of Biological Science and Technology, Institute of Molecular Medicine and Bioengineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
1 shared publication- Jiajie Diao
Department of Cancer Biology University of Cincinnati College of Medicine Cincinnati Ohio USA
1 shared publication - Jun Shen
Department of Material Science and Engineering, Chongqing University, Chongqing, China
1 shared publication - Matthew Chae
Department of Cancer Biology, University of Cincinnati College of Medicine, Cincinnati, OH 45267, USA
1 shared publication
Latest Publications
- Open Access
- 3 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (8) , 923
Programmable Digital-Microfluidic Biochips for SARS-CoV-2 Detection
Biochips, a novel technology in the field of biomolecular analysis, offer a promising alternative to conventional testing equipment. These chips integrate multiple functions within a single system, providing a compact and efficient solution for various testing needs. For biochips, a pattern-control micro-electrode-dot-array (MEDA) is a new, universally viable design that can replace microchannels and other micro-components. In a Micro Electrode Dot Array (MEDA), each electrode can be programmatically controlled or dynamically grouped, allowing a single chip to fulfill the diverse requirements of different tests. This capability not only enhances flexibility, but also contributes to cost reduction by eliminating the need for multiple specialized chips. In this paper, we present a visible biochip testing system for tracking the entire testing process in real time, and describe our application of the system to detect SARS-CoV-2.
- 3 August 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (8) , 923
Open AccessProgrammable Digital-Microfluidic Biochips for SARS-CoV-2 Detection
Biochips, a novel technology in the field of biomolecular analysis, offer a promising alternative to conventional testing equipment. These chips integrate multiple functions within a single system, providing a compact and efficient solution for various testing needs. For biochips, a pattern-control micro-electrode-dot-array (MEDA) is a new, universally viable design that can replace microchannels and other micro-components. In a Micro Electrode Dot Array (MEDA), each electrode can be programmatically controlled or dynamically grouped, allowing a single chip to fulfill the diverse requirements of different tests. This capability not only enhances flexibility, but also contributes to cost reduction by eliminating the need for multiple specialized chips. In this paper, we present a visible biochip testing system for tracking the entire testing process in real time, and describe our application of the system to detect SARS-CoV-2.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (11) , 4513-4517
A Programmable Bio-Chip With Adaptive Pattern-Control Micro-Electrode-Dot-Array
A digital lab-on-CMOS chip is presented for nucleic acid amplification test. This biochip consists of programmable microelectrode dot array and digital timing controller. With novel circuit design in each microelectrode, microfluidic operations with velocity of 0.6mm/s, temperature profile with maximum change rate of 4.5°C/s and location sensing in $\mu $ second-level can be achieved. As a result, test samples can be located first, followed by target operations to meet the requirements of specific medical tests with less reagent consumption and test time/cost. Furthermore bio-protocols can be derived to ensure both replicability and reliability in various medical tests. Preliminary results in loop-mediated isothermal amplification (LAMP) and PCR thermal cycle tests demonstrate the feasibility of our proposal with less test time of < 40 min and < 1 min respectively, making our proposal very suitable for mobile healthcare applications.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (11) , 4513-4517
A Programmable Bio-Chip With Adaptive Pattern-Control Micro-Electrode-Dot-Array
A digital lab-on-CMOS chip is presented for nucleic acid amplification test. This biochip consists of programmable microelectrode dot array and digital timing controller. With novel circuit design in each microelectrode, microfluidic operations with velocity of 0.6mm/s, temperature profile with maximum change rate of 4.5°C/s and location sensing in $\mu $ second-level can be achieved. As a result, test samples can be located first, followed by target operations to meet the requirements of specific medical tests with less reagent consumption and test time/cost. Furthermore bio-protocols can be derived to ensure both replicability and reliability in various medical tests. Preliminary results in loop-mediated isothermal amplification (LAMP) and PCR thermal cycle tests demonstrate the feasibility of our proposal with less test time of < 40 min and < 1 min respectively, making our proposal very suitable for mobile healthcare applications.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 1582-1586
A Traveling-Wave Dielectrophoresis Bio-Chip for Cell Manipulation in Standard CMOS Process
This brief presents a lab-on-a-chip for cancer cell manipulation and separation. The programmable microelectrode dot array with 115,200 sub-microelectrodes is used to generate traveling wave electric field on the proposed chip. The proposed sub-microelectrode, $5\times 5\,\,\mu {\mathrm{ m}}^{2}$ , is useful to improve the traveling field strength under low applied voltage. The proposed chip with area size of $3.2\times 2.2$ mm 2 is implemented in standard 0.18 $\mu {\mathrm{ m}}$ CMOS process. Experimental results show that MDA-MB-231 cells and HELA cells can be manipulated at the speed of 1.08 $\mu {\mathrm{ m}}$ /s and 1.5 $\mu {\mathrm{ m}}$ /s respectively under the supply voltage of 1.8V.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 1582-1586
A Traveling-Wave Dielectrophoresis Bio-Chip for Cell Manipulation in Standard CMOS Process
This brief presents a lab-on-a-chip for cancer cell manipulation and separation. The programmable microelectrode dot array with 115,200 sub-microelectrodes is used to generate traveling wave electric field on the proposed chip. The proposed sub-microelectrode, $5\times 5\,\,\mu {\mathrm{ m}}^{2}$ , is useful to improve the traveling field strength under low applied voltage. The proposed chip with area size of $3.2\times 2.2$ mm 2 is implemented in standard 0.18 $\mu {\mathrm{ m}}$ CMOS process. Experimental results show that MDA-MB-231 cells and HELA cells can be manipulated at the speed of 1.08 $\mu {\mathrm{ m}}$ /s and 1.5 $\mu {\mathrm{ m}}$ /s respectively under the supply voltage of 1.8V.
- 1 October 2009
- Published by Elsevier in Acta Materialia
- Vol. 57 (17) , 5196-5206
Growth mechanism of Ni3Sn4 in a Sn/Ni liquid/solid interfacial reaction
- 1 October 2009
- Published by Elsevier in Acta Materialia
- Vol. 57 (17) , 5196-5206
Growth mechanism of Ni3Sn4 in a Sn/Ni liquid/solid interfacial reaction