Jianfeng Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianfeng Yao has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Zhibin Tu
College of Civil Engineering and Architecture, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
10 shared publications - Guohui Shen
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
9 shared publications - Wenjuan Lou
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, China
6 shared publications - Dong Wang
China Energy Engineering Group, Zhejiang Electric Power Design Institute Co., Ltd., Hangzhou 310012, China
3 shared publications - Shice Yu
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
3 shared publications Bing Lu
College of Civil Engineering and Architecture, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
2 shared publications
Latest Publications
- Open Access
Structural Response and Failure Analysis of Transmission Towers Under Foundation Sliding with Consideration of Wind Effects
To investigate the failure evolution and structural response of transmission towers under the combined effects of foundation sliding and wind loads, this study used the foundation sliding incident of Tower No. 39 on the Xiaoxing transmission line as a case for numerical back-analysis. A transmission tower model was first developed based on the finite element method, and the simulation results were compared with field observations to validate the model, with particular focus on the consistency of typical failure modes such as leg bending and cross-bracing instability. On this basis, the structural response under the combined action of foundation lateral displacement, settlement, and wind loads was further simulated. The results indicate that foundation sliding significantly affects the structural stability of transmission towers, with single-foundation sliding being more destructive than the simultaneous sliding of multiple foundations on the same side. Moreover, the coupling of foundation sliding and wind load substantially reduces the critical displacement required to trigger structural failure. Finally, critical displacement thresholds are proposed, which can serve as reference criteria for damage assessment and engineering intervention when changes in foundation conditions occur.
Open AccessStructural Response and Failure Analysis of Transmission Towers Under Foundation Sliding with Consideration of Wind Effects
To investigate the failure evolution and structural response of transmission towers under the combined effects of foundation sliding and wind loads, this study used the foundation sliding incident of Tower No. 39 on the Xiaoxing transmission line as a case for numerical back-analysis. A transmission tower model was first developed based on the finite element method, and the simulation results were compared with field observations to validate the model, with particular focus on the consistency of typical failure modes such as leg bending and cross-bracing instability. On this basis, the structural response under the combined action of foundation lateral displacement, settlement, and wind loads was further simulated. The results indicate that foundation sliding significantly affects the structural stability of transmission towers, with single-foundation sliding being more destructive than the simultaneous sliding of multiple foundations on the same side. Moreover, the coupling of foundation sliding and wind load substantially reduces the critical displacement required to trigger structural failure. Finally, critical displacement thresholds are proposed, which can serve as reference criteria for damage assessment and engineering intervention when changes in foundation conditions occur.
- Open Access
Effects of Corrosion Depth on Wind-Induced Collapse Performance of an Angle Steel Transmission Tower
Transmission towers in coastal and industrial areas have experienced significant corrosion due to prolonged exposure to atmospheric pollutants and saline moisture, which poses a risk to structural safety. To evaluate the impact of corrosion depth on wind-induced collapse performance of an angle steel transmission tower, a survey of 18 angle steel towers in Ningbo, China, was conducted. Finite element models (FEMs) incorporating observed corrosion patterns were developed to analyze natural vibration characteristics and progressive collapse. The collapse modes of both corroded and uncorroded towers were identified, and high-risk failure member was determined. The results indicate that the corrosion depth below the lower cross-arm can be considered representative of the overall corrosion condition of the tower. Torsional natural frequency of the angle steel tower is particularly sensitive to corrosion due to the critical role of diagonal members. Collapse analysis further reveals that moderate corrosion levels can reduce the tower’s wind resistance to below the design threshold, potentially compromising safety under extreme weather conditions. The diagonal member below the lower cross-arm is identified as a high-risk failure component. Strengthening this member, by up-grading from L75×6 to L90×6, can significantly enhance the tower’s tolerance to corrosion.
Open AccessEffects of Corrosion Depth on Wind-Induced Collapse Performance of an Angle Steel Transmission Tower
Transmission towers in coastal and industrial areas have experienced significant corrosion due to prolonged exposure to atmospheric pollutants and saline moisture, which poses a risk to structural safety. To evaluate the impact of corrosion depth on wind-induced collapse performance of an angle steel transmission tower, a survey of 18 angle steel towers in Ningbo, China, was conducted. Finite element models (FEMs) incorporating observed corrosion patterns were developed to analyze natural vibration characteristics and progressive collapse. The collapse modes of both corroded and uncorroded towers were identified, and high-risk failure member was determined. The results indicate that the corrosion depth below the lower cross-arm can be considered representative of the overall corrosion condition of the tower. Torsional natural frequency of the angle steel tower is particularly sensitive to corrosion due to the critical role of diagonal members. Collapse analysis further reveals that moderate corrosion levels can reduce the tower’s wind resistance to below the design threshold, potentially compromising safety under extreme weather conditions. The diagonal member below the lower cross-arm is identified as a high-risk failure component. Strengthening this member, by up-grading from L75×6 to L90×6, can significantly enhance the tower’s tolerance to corrosion.
- Open Access
- 25 October 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (21) , 9274
Numerical Simulation Investigation of Wind Field Characteristics and Acceleration Effects over V-Shaped Hills
Wind energy resources play an important role in sustainable development, and the accelerating effect of wind has been found in V-shaped hills, which informs the siting of wind turbines in this type of terrain. The wind field around the V-shaped hill was simulated using the CFD method. The impact of wind angle, hill pinch angle, and the distance between the hills on the wind field around the V-shaped hill was investigated. Wind acceleration effects at specific locations were studied and analyzed, and these findings were compared with established codes. It was observed that the wind speed at the hill’s top under each wind angle is significantly higher compared to other areas. Additionally, the acceleration ratio at the top generally exhibits a decreasing trend with increasing height. If the wind angle is 15° and the pinch angle is greater than or equal to 15°, or if the distance between the hills is less than or equal to 50 m, the wake zone will gradually transition from two to one. The distance between the hills minimally affects the acceleration ratio at the mid-height and top of the hill. Several codes exhibit inconsistency in specifying acceleration effects in hilly terrain. The findings in this paper align most closely with the American code at the base of the hill. At the hill’s top, the American code is the lowest above 100 m, while the Chinese code is the highest below 100 m. The findings in this paper fall between those of the Japanese and Australian codes. The formulas for the variation in wind speed acceleration ratio at typical locations with respect to height and the angle between the hills are provided.
- 25 October 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (21) , 9274
Open AccessNumerical Simulation Investigation of Wind Field Characteristics and Acceleration Effects over V-Shaped Hills
Wind energy resources play an important role in sustainable development, and the accelerating effect of wind has been found in V-shaped hills, which informs the siting of wind turbines in this type of terrain. The wind field around the V-shaped hill was simulated using the CFD method. The impact of wind angle, hill pinch angle, and the distance between the hills on the wind field around the V-shaped hill was investigated. Wind acceleration effects at specific locations were studied and analyzed, and these findings were compared with established codes. It was observed that the wind speed at the hill’s top under each wind angle is significantly higher compared to other areas. Additionally, the acceleration ratio at the top generally exhibits a decreasing trend with increasing height. If the wind angle is 15° and the pinch angle is greater than or equal to 15°, or if the distance between the hills is less than or equal to 50 m, the wake zone will gradually transition from two to one. The distance between the hills minimally affects the acceleration ratio at the mid-height and top of the hill. Several codes exhibit inconsistency in specifying acceleration effects in hilly terrain. The findings in this paper align most closely with the American code at the base of the hill. At the hill’s top, the American code is the lowest above 100 m, while the Chinese code is the highest below 100 m. The findings in this paper fall between those of the Japanese and Australian codes. The formulas for the variation in wind speed acceleration ratio at typical locations with respect to height and the angle between the hills are provided.
- Open Access
- 11 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (20) , 14767
Use of Modal Substructure Method to Improve Wind-Resistance Design of Twin Towers
To provide guidance for the wind-resistant design of super-tall twin towers, this study proposes a new method for the wind-induced response computation and wind-resistant design optimization of twin towers, named the Modal Substructure (MSS) method. The MSS method is established through theoretical deduction, which is utilized to investigate the effects of links on the structural dynamic characteristics of twin towers via parameter analysis. The results show that, in the in-phase mode, the structural link increases the generalized mass of the “linked tower” system but insignificantly affects its stiffness and damping. However, in the out-of-phase mode, the link increases the overall damping and stiffness of the “linked tower” system, with negligible effects on the inertia characteristics of the entire structure. Finally, the accuracy of the MSS method is validated using 570 m-high twin towers as a case study. It was found that although the MSS method is an approximate approach, its results exhibit good accuracy and convenience in exploring the impact of link properties on the dynamic characteristics of twin towers. Therefore, the MSS method can be effectively used to guide the wind-resistant design of linked twin towers.
- 11 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (20) , 14767
Open AccessUse of Modal Substructure Method to Improve Wind-Resistance Design of Twin Towers
To provide guidance for the wind-resistant design of super-tall twin towers, this study proposes a new method for the wind-induced response computation and wind-resistant design optimization of twin towers, named the Modal Substructure (MSS) method. The MSS method is established through theoretical deduction, which is utilized to investigate the effects of links on the structural dynamic characteristics of twin towers via parameter analysis. The results show that, in the in-phase mode, the structural link increases the generalized mass of the “linked tower” system but insignificantly affects its stiffness and damping. However, in the out-of-phase mode, the link increases the overall damping and stiffness of the “linked tower” system, with negligible effects on the inertia characteristics of the entire structure. Finally, the accuracy of the MSS method is validated using 570 m-high twin towers as a case study. It was found that although the MSS method is an approximate approach, its results exhibit good accuracy and convenience in exploring the impact of link properties on the dynamic characteristics of twin towers. Therefore, the MSS method can be effectively used to guide the wind-resistant design of linked twin towers.
- Open Access
- 15 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13805
Effects of Cornices on Wind Loads of Solar Panels Mounted on Gable Roof Building
The effects of various parameters of the solar panel and surrounding structure on wind loads acting on solar panels have been extensively investigated in prior studies. However, the parameter of cornice length has not been considered. With varying lengths of cornices, solar panels can be positioned either near or far away from the roof corner and edge, which are the locations where the largest wind-induced suction forces are likely to occur. To examine the effects of cornices, a wind tunnel test was conducted to measure the wind pressures on a solar module installed on a residential gable roof building. The cornice lengths varied from 0 m to 1.6 m, with an interval of 0.4 m. The results show that when wind blows perpendicular to the roof ridge, cornice can reduce the mean, STD, and peak pressure coefficients on the upper and lower surfaces and resulting net values. However, it should be noted that the most unfavorable area-averaged minimum peaks in the middle and trailing zones exhibit a gradual increase with the growing cornice length. Considering the potential risk of solar module failure resulting from high wind-induced suction forces, more caution is needed when installing solar modules on roofs with larger cornices.
- 15 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13805
Open AccessEffects of Cornices on Wind Loads of Solar Panels Mounted on Gable Roof Building
The effects of various parameters of the solar panel and surrounding structure on wind loads acting on solar panels have been extensively investigated in prior studies. However, the parameter of cornice length has not been considered. With varying lengths of cornices, solar panels can be positioned either near or far away from the roof corner and edge, which are the locations where the largest wind-induced suction forces are likely to occur. To examine the effects of cornices, a wind tunnel test was conducted to measure the wind pressures on a solar module installed on a residential gable roof building. The cornice lengths varied from 0 m to 1.6 m, with an interval of 0.4 m. The results show that when wind blows perpendicular to the roof ridge, cornice can reduce the mean, STD, and peak pressure coefficients on the upper and lower surfaces and resulting net values. However, it should be noted that the most unfavorable area-averaged minimum peaks in the middle and trailing zones exhibit a gradual increase with the growing cornice length. Considering the potential risk of solar module failure resulting from high wind-induced suction forces, more caution is needed when installing solar modules on roofs with larger cornices.
- Open Access
Wind-Induced Responses of Corroded Angle-Steel Transmission Tower
Corroded transmission towers, whose load-bearing capacities are lowered, are suffering from wind-induced damage. By simulating the member corrosion through section thinning, the structural dynamic finite element model of an angle-steel transmission tower with a corrosion depth of 0 mm to 1.4 mm was established using ANSYS/LS-DYNA software. The incremental dynamic analysis method was used to study the collapse mode of the tower under different degrees of corrosion, as well as the effects of corrosion on structural self-vibration characteristics, wind-induced member stress, and tower-top displacement. The results show that with the corrosion deepening, the first three vibration frequencies decrease, and the torsional mode becomes the first mode. When the corrosion depth is smaller, the overall structure failure occurs under strong wind. The failure starts at the most unfavorable oblique rod between the upper and middle cross arm, then expands to the rods under the lower cross arm. When the corrosion depth is larger, the overall structure failure occurs restrictedly between the upper and middle cross arm. Internal axial force and bending moment redistribution happen when corrosion deepens. Under the critical failure state, the oblique rods are always at a high stress level, while the stresses of the main rods decrease. Corrosion has a stronger impact on component strength and stability than on structural stiffness.
Open AccessWind-Induced Responses of Corroded Angle-Steel Transmission Tower
Corroded transmission towers, whose load-bearing capacities are lowered, are suffering from wind-induced damage. By simulating the member corrosion through section thinning, the structural dynamic finite element model of an angle-steel transmission tower with a corrosion depth of 0 mm to 1.4 mm was established using ANSYS/LS-DYNA software. The incremental dynamic analysis method was used to study the collapse mode of the tower under different degrees of corrosion, as well as the effects of corrosion on structural self-vibration characteristics, wind-induced member stress, and tower-top displacement. The results show that with the corrosion deepening, the first three vibration frequencies decrease, and the torsional mode becomes the first mode. When the corrosion depth is smaller, the overall structure failure occurs under strong wind. The failure starts at the most unfavorable oblique rod between the upper and middle cross arm, then expands to the rods under the lower cross arm. When the corrosion depth is larger, the overall structure failure occurs restrictedly between the upper and middle cross arm. Internal axial force and bending moment redistribution happen when corrosion deepens. Under the critical failure state, the oblique rods are always at a high stress level, while the stresses of the main rods decrease. Corrosion has a stronger impact on component strength and stability than on structural stiffness.
- Open Access
- 13 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5052
Experimental Investigation of the Parapet Effect on the Wind Load of Roof-Mounted Solar Arrays
A wind tunnel test was conducted to investigate the effects of parapets on the aerodynamic wind loads of roof-mounted solar arrays. The distribution of the mean wind pressure coefficient and the extreme wind pressure coefficient in the solar arrays were discussed in detail, and the results were compared with some national standards. Results show that the mean and extreme values of the wind pressure coefficient are larger at oblique wind angles. The presence of the parapet can reduce the mean and extreme area-averaged net pressure coefficients in some areas of the solar arrays, and both the most critical positive and negative shape factors reduce at the corner and outer rows while less change occurs at the inner zones. The experimental shape factors are much smaller compared to the values calculated by the standards. The guidelines for the design of wind pressure on roof-mounted solar arrays are very conservative, and more research is needed to make the standards applicable and complete.
- 13 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5052
Open AccessExperimental Investigation of the Parapet Effect on the Wind Load of Roof-Mounted Solar Arrays
A wind tunnel test was conducted to investigate the effects of parapets on the aerodynamic wind loads of roof-mounted solar arrays. The distribution of the mean wind pressure coefficient and the extreme wind pressure coefficient in the solar arrays were discussed in detail, and the results were compared with some national standards. Results show that the mean and extreme values of the wind pressure coefficient are larger at oblique wind angles. The presence of the parapet can reduce the mean and extreme area-averaged net pressure coefficients in some areas of the solar arrays, and both the most critical positive and negative shape factors reduce at the corner and outer rows while less change occurs at the inner zones. The experimental shape factors are much smaller compared to the values calculated by the standards. The guidelines for the design of wind pressure on roof-mounted solar arrays are very conservative, and more research is needed to make the standards applicable and complete.
- Open Access
- 24 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 15653
Computational Investigation of Wind Loads on Tilted Roof-Mounted Solar Array
A detailed computational investigation of the wind field around tilted solar modules mounted on a large building roof has been undertaken, utilizing the Reynolds-Averaged Navier-Stokesv (RANS) approach supplied with the SST k − ω turbulence model. The study investigated the flow field for various tilt angle of modules at normal wind directions relative to the wall. Then the shape factors and moment coefficients of modules were explored. The results show that the recirculation vortex generated by the building edge is disintegrated to smaller local vortices. With the increasing of the tilt angle, an increasing number of local vortices emerged at the leading rows, leading to a relatively large wind pressure and shape factor at the corner of the array. In most tilt angles at 0° and 180° wind direction the shape factors are negative. However, for the 40° and 55° tilt angles at 180° wind direction, the shape factors on the lower surfaces are positive, due to the dominating of approaching flow rather than the local vortices. The array is divided into six zones based on the distribution of shape factors. As the shape factors on upper and lower are similar, the shape factors in most zones for tilt angles from 5° to 55° are quite small. However, shape factors in the leading row for 30°, 40° and 55° are relatively large. This indicates that the shading effect of front rows can significantly reduce the shape factors of the rear rows. Compared to the values calculated by Chinese, American and Japanese standards, the shape factors by simulation are quite small. The moment induced by nonuniform wind pressure, which is often ignored in the literature and standards, is quite large at the leading zones, with a maximum of 0.28 for 55° tilt angle. Ignoring the wind induced moment on the leading zones may make the wind resistance design of the solar module support structure unsafe.
- 24 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 15653
Open AccessComputational Investigation of Wind Loads on Tilted Roof-Mounted Solar Array
A detailed computational investigation of the wind field around tilted solar modules mounted on a large building roof has been undertaken, utilizing the Reynolds-Averaged Navier-Stokesv (RANS) approach supplied with the SST k − ω turbulence model. The study investigated the flow field for various tilt angle of modules at normal wind directions relative to the wall. Then the shape factors and moment coefficients of modules were explored. The results show that the recirculation vortex generated by the building edge is disintegrated to smaller local vortices. With the increasing of the tilt angle, an increasing number of local vortices emerged at the leading rows, leading to a relatively large wind pressure and shape factor at the corner of the array. In most tilt angles at 0° and 180° wind direction the shape factors are negative. However, for the 40° and 55° tilt angles at 180° wind direction, the shape factors on the lower surfaces are positive, due to the dominating of approaching flow rather than the local vortices. The array is divided into six zones based on the distribution of shape factors. As the shape factors on upper and lower are similar, the shape factors in most zones for tilt angles from 5° to 55° are quite small. However, shape factors in the leading row for 30°, 40° and 55° are relatively large. This indicates that the shading effect of front rows can significantly reduce the shape factors of the rear rows. Compared to the values calculated by Chinese, American and Japanese standards, the shape factors by simulation are quite small. The moment induced by nonuniform wind pressure, which is often ignored in the literature and standards, is quite large at the leading zones, with a maximum of 0.28 for 55° tilt angle. Ignoring the wind induced moment on the leading zones may make the wind resistance design of the solar module support structure unsafe.
- Open Access
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14272
Investigation of Coupling Effects of Wave, Current, and Wind on a Pile Foundation
To investigate the coupling effects of wave–wind, wave–current, and wave–current–wind on a pile foundation of a marine structure, harbor basin tests on loads induced by single and combined action of wave, current, and wind were conducted. The time histories, power spectrums, and characteristic values of drag forces in the test conditions were compared. Then, the coupling coefficients were calculated based on the characteristic values to quantitively evaluate the coupling effects. The influence of natural vibration of the pile on the characteristic values and coupling effects were studied by comparing the test loads between rigid and elastic models. The results show that the shapes of power spectrums of drag forces and their peak frequencies in the wave-involved conditions are similar to the spectrum of incident wave, which means that the steady current and uniform wind cannot change the frequency distribution of incident random wave. Although the drag forces of rigid and elastic model under wave–wind, wave–current, and wave–current–wind are not the linear superposition of corresponding single field, the coupling effects among them are quite weak as the coupling coefficients are small. It is speculated that the weak wave–wind coupling effect may be because, firstly, the interaction of wave and wind is limited to the zone near the water surface, which is far less than the height of the model; secondly, the wave-induced load is dominant compared to wind and current. The loads in test conditions of elastic model are similar to the rigid model; for that, the model’s natural frequency is far away from the peak spectral frequency of incident wave, having little influence on the drag force.
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14272
Open AccessInvestigation of Coupling Effects of Wave, Current, and Wind on a Pile Foundation
To investigate the coupling effects of wave–wind, wave–current, and wave–current–wind on a pile foundation of a marine structure, harbor basin tests on loads induced by single and combined action of wave, current, and wind were conducted. The time histories, power spectrums, and characteristic values of drag forces in the test conditions were compared. Then, the coupling coefficients were calculated based on the characteristic values to quantitively evaluate the coupling effects. The influence of natural vibration of the pile on the characteristic values and coupling effects were studied by comparing the test loads between rigid and elastic models. The results show that the shapes of power spectrums of drag forces and their peak frequencies in the wave-involved conditions are similar to the spectrum of incident wave, which means that the steady current and uniform wind cannot change the frequency distribution of incident random wave. Although the drag forces of rigid and elastic model under wave–wind, wave–current, and wave–current–wind are not the linear superposition of corresponding single field, the coupling effects among them are quite weak as the coupling coefficients are small. It is speculated that the weak wave–wind coupling effect may be because, firstly, the interaction of wave and wind is limited to the zone near the water surface, which is far less than the height of the model; secondly, the wave-induced load is dominant compared to wind and current. The loads in test conditions of elastic model are similar to the rigid model; for that, the model’s natural frequency is far away from the peak spectral frequency of incident wave, having little influence on the drag force.
- Open Access
- 15 September 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (18) , 11613
Wind Tunnel Tests of an Aeroelastic Model of a Long-Span Transmission Tower
The modal analysis of a long-span transmission tower was carried out using a finite element method, and then its aeroelastic model was established by the discrete stiffness method for wind tunnel tests. The displacement and acceleration of the aeroelastic model were measured by a vision-based displacement measuring instrument and accelerometer, respectively. Also, the wind-induced responses of the tower were conducted by finite element calculation, with which the results of the wind tunnel tests are compared. The gust response factor was calculated and compared with those from the specifications and other studies. The results show that the vision-based displacement instrument can record well the vibration of the model tower in the wind tunnel. The acceleration of the tower is dominated by the first-order resonant response, whereas the displacement is dominated by the background response. The displacement and acceleration in the longitudinal and transversal directions are almost equal, indicating that the crosswind and along-wind responses are of the same magnitude. The displacement atop the tower obtained from the test after considering the Reynolds number correction almost coincided with that from the numerical simulation. The gust response factor of the tower obtained via wind tunnel tests is smaller than that of the codes and close to that found via finite element calculations.
- 15 September 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (18) , 11613
Open AccessWind Tunnel Tests of an Aeroelastic Model of a Long-Span Transmission Tower
The modal analysis of a long-span transmission tower was carried out using a finite element method, and then its aeroelastic model was established by the discrete stiffness method for wind tunnel tests. The displacement and acceleration of the aeroelastic model were measured by a vision-based displacement measuring instrument and accelerometer, respectively. Also, the wind-induced responses of the tower were conducted by finite element calculation, with which the results of the wind tunnel tests are compared. The gust response factor was calculated and compared with those from the specifications and other studies. The results show that the vision-based displacement instrument can record well the vibration of the model tower in the wind tunnel. The acceleration of the tower is dominated by the first-order resonant response, whereas the displacement is dominated by the background response. The displacement and acceleration in the longitudinal and transversal directions are almost equal, indicating that the crosswind and along-wind responses are of the same magnitude. The displacement atop the tower obtained from the test after considering the Reynolds number correction almost coincided with that from the numerical simulation. The gust response factor of the tower obtained via wind tunnel tests is smaller than that of the codes and close to that found via finite element calculations.