LLLunxin Liu

Lunxin Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lunxin Liu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    From Variant Interpretation to Biomarker Translation: Multi‐omics Integration in Inherited Neuromuscular Diseases

    by Suming Zhang, Xiaoling Lang, Lunxin Liu

    Genetic neuromuscular diseases are highly heterogeneous disorders characterized by diagnostic challenges and limited therapeutic options, underscoring an urgent need for precise biomarkers. The rapid advancement of multi‐omics technologies has broadened biomarker discovery from single genomics to multidimensional integrative analyses encompassing transcriptomics, proteomics, and metabolomics. This progression offers opportunities to improve disease diagnosis, subtyping, prognosis assessment, and treatment monitoring. However, translational gaps persist between multi‐omics discoveries and clinically applicable biomarkers. This review systematically examines the current application of multi‐omics biomarkers in genetic neuromuscular diseases. It provides an in‐depth analysis of the multifaceted barriers encountered during the translation process, including technical hurdles, clinical validation complexities, data interpretation challenges, and health system‐level obstacles. Furthermore, the review explores emerging solutions including artificial intelligence‐assisted decision‐making, ethical governance, and policy preparedness. The review aims to offer a framework for constructing a potentially responsible and efficient multi‐omics translation in genetic neuromuscular diseases.

  • Rupture of Dural Arteriovenous Fistula During 3-Dimensional DSA

    by Lunxin Liu, Jian Wang, Fayun Hu, Li He, Chaohua Wang

  • Open Access

    Blood-Blister Aneurysms of the Internal Carotid Artery in Tibetan and Han Populations : A Retrospective Observational Study

    by Bowen Huang, Yanming Ren, Hao Liu, Anqi Xiao, Lunxin Liu, Hong Sun, Yi Liu, Lu Ma, Chang-Wei Zhang, Chao-Hua Wang, et al.

    Objective : Blood-blister aneurysms (BBAs) of the internal carotid artery (ICA) are challenging lesions with high morbidity and mortality rates. Although research on BBAs is well documented in different populations, the study of BBAs in the Tibetan population is extremely rare. This study aimed to evaluate the characteristics of BBAs and analyze the treatment modalities and long-term outcomes in the Tibetan population in comparison with the Han population.Methods : The characteristics of patients with BBAs of the ICA from January 2009 to January 2021 at our institution were reviewed. The features of aneurysms, treatment modalities, complications, and follow-up outcomes were retrospectively analyzed.Results : A total of 130 patients (41 Tibetan and 89 Han patients) with BBAs of the ICA who underwent treatment were enrolled. Compared with the Han group, the Tibetan group significantly demonstrated a high ratio of BBAs among ICAs (8.6%, 41/477 vs. 1.6%, 89/5563; p<0.05), a high ratio of vasospasm (34.1%, 14/41 vs. 6.7%, 6/89; p=0.001), a high risk of ischemic events (43.9%, 18/41 vs. 22.5%, 20/89; p<0.05), and a low ratio of good outcomes (modified Rankin scale, 0–2) at the 1-year follow-up (51.2%, 21/41 vs. 74.2%, 66/89; p<0.05). The multivariate regression model showed that ischemic events significantly contributed to the prediction of outcomes at 1 year. Further analysis revealed that microsurgery and vasospasm were associated with ischemic events.Conclusion : In comparison with Han patients, the Tibetan population had a high ratio of BBA occurrence, a high incidence of ischemic events, and a high ratio of poor outcomes. The endovascular approach showed more benefits in BBA patients.


  • Open Access

    Using a Convolutional Neural Network and Convolutional Long Short-term Memory to Automatically Detect Aneurysms on 2D Digital Subtraction Angiography Images: Framework Development and Validation

    by JunHua Liao, LunXin Liu, HaiHan Duan, YunZhi Huang, LiangXue Zhou, LiangYin Chen, ChaoHua Wang

    Background: It is hard to distinguish cerebral aneurysms from overlapping vessels in 2D digital subtraction angiography (DSA) images due to these images’ lack of spatial information. Objective: The aims of this study were to (1) construct a deep learning diagnostic system to improve the ability to detect posterior communicating artery aneurysms on 2D DSA images and (2) validate the efficiency of the deep learning diagnostic system in 2D DSA aneurysm detection. Methods: We proposed a 2-stage detection system. First, we established the region localization stage to automatically locate specific detection regions of raw 2D DSA sequences. Second, in the intracranial aneurysm detection stage, we constructed a bi-input+RetinaNet+convolutional long short-term memory (C-LSTM) framework to compare its performance for aneurysm detection with that of 3 existing frameworks. Each of the frameworks had a 5-fold cross-validation scheme. The receiver operating characteristic curve, the area under the curve (AUC) value, mean average precision, sensitivity, specificity, and accuracy were used to assess the abilities of different frameworks. Results: A total of 255 patients with posterior communicating artery aneurysms and 20 patients without aneurysms were included in this study. The best AUC values of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks were 0.95, 0.96, 0.92, and 0.97, respectively. The mean sensitivities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 89% (range 67.02%-98.43%), 88% (range 65.76%-98.06%), 87% (range 64.53%-97.66%), 89% (range 67.02%-98.43%), and 90% (range 68.30%-98.77%), respectively. The mean specificities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 80% (range 56.34%-94.27%), 89% (range 67.02%-98.43%), 86% (range 63.31%-97.24%), 93% (range 72.30%-99.56%), and 90% (range 68.30%-98.77%), respectively. The mean accuracies of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 84.50% (range 69.57%-93.97%), 88.50% (range 74.44%-96.39%), 86.50% (range 71.97%-95.22%), 91% (range 77.63%-97.72%), and 90% (range 76.34%-97.21%), respectively. Conclusions: According to our results, more spatial and temporal information can help improve the performance of the frameworks. Therefore, the bi-input+RetinaNet+C-LSTM framework had the best performance when compared to that of the other frameworks. Our study demonstrates that our system can assist physicians in detecting intracranial aneurysms on 2D DSA images.


  • Open Access

    Using a Convolutional Neural Network and Convolutional Long Short-term Memory to Automatically Detect Aneurysms on 2D Digital Subtraction Angiography Images: Framework Development and Validation (Preprint)

    by JunHua Liao, LunXin Liu, HaiHan Duan, YunZhi Huang, LiangXue Zhou, LiangYin Chen, ChaoHua Wang

    BACKGROUND It is hard to distinguish cerebral aneurysms from overlapping vessels in 2D digital subtraction angiography (DSA) images due to these images’ lack of spatial information. OBJECTIVE The aims of this study were to (1) construct a deep learning diagnostic system to improve the ability to detect posterior communicating artery aneurysms on 2D DSA images and (2) validate the efficiency of the deep learning diagnostic system in 2D DSA aneurysm detection. METHODS We proposed a 2-stage detection system. First, we established the region localization stage to automatically locate specific detection regions of raw 2D DSA sequences. Second, in the intracranial aneurysm detection stage, we constructed a bi-input+RetinaNet+convolutional long short-term memory (C-LSTM) framework to compare its performance for aneurysm detection with that of 3 existing frameworks. Each of the frameworks had a 5-fold cross-validation scheme. The receiver operating characteristic curve, the area under the curve (AUC) value, mean average precision, sensitivity, specificity, and accuracy were used to assess the abilities of different frameworks. RESULTS A total of 255 patients with posterior communicating artery aneurysms and 20 patients without aneurysms were included in this study. The best AUC values of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks were 0.95, 0.96, 0.92, and 0.97, respectively. The mean sensitivities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 89% (range 67.02%-98.43%), 88% (range 65.76%-98.06%), 87% (range 64.53%-97.66%), 89% (range 67.02%-98.43%), and 90% (range 68.30%-98.77%), respectively. The mean specificities of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 80% (range 56.34%-94.27%), 89% (range 67.02%-98.43%), 86% (range 63.31%-97.24%), 93% (range 72.30%-99.56%), and 90% (range 68.30%-98.77%), respectively. The mean accuracies of the RetinaNet, RetinaNet+C-LSTM, bi-input+RetinaNet, and bi-input+RetinaNet+C-LSTM frameworks and human experts were 84.50% (range 69.57%-93.97%), 88.50% (range 74.44%-96.39%), 86.50% (range 71.97%-95.22%), 91% (range 77.63%-97.72%), and 90% (range 76.34%-97.21%), respectively. CONCLUSIONS According to our results, more spatial and temporal information can help improve the performance of the frameworks. Therefore, the bi-input+RetinaNet+C-LSTM framework had the best performance when compared to that of the other frameworks. Our study demonstrates that our system can assist physicians in detecting intracranial aneurysms on 2D DSA images.


  • Prognosis research of delayed facial palsy after microvascular decompression for hemifacial spasm

    by Lun-Xin Liu, Chang-Wei Zhang, Peng-Wei Ren, Shou-Wei Xiang, Ding Xu, Xiao-Dong Xie, Heng Zhang

    Although microvascular decompression (MVD) surgery has been widely accepted as an effective treatment for hemifacial spasm (HFS), delayed facial palsy (DFP) is not an unusual complication, but it has only been sporadically described in the literature. The purpose of this study was to examine the probability of occurrence, the risk/predisposing factors, and the prognosis and timing of DFP. A prospective cohort study was conducted that included patients diagnosed with HFS and treated by MVD at our institution. All patients were followed up at the outpatient department or by telephone from December 2009 to December 2014. Categorical variables were analyzed using the Pearson’s Chi-square test or Fisher’s exact test. Continuous variables were compared using the independent Student’s t test. The Spearman rank test was used to determine the correlation between the time of onset and the duration of DFP. The risk/predisposing factors were analyzed by the logistic regression method. We enrolled 248 patients who were treated by MVD for HFS. During the follow-up period, 16 patients (6.5 %) developed DFP. Fifteen of those patients had a complete recovery, and in one patient the facial palsy did not resolve. The average onset time was 10.2 days (range, 2–30 days) after surgery, and the mean duration of DFP after MVD, with exclusion of the permanent facial palsy patient, was 59.7 days (range, 7–220 days). The time of onset was correlated with the duration of DFP after MVD (p = 0.036). Furthermore, hypertension contributed to DFP (odds ratio [OR] 4.226, 95 % confidence interval [CI] 1.089–16.401, p = 0.037). Although the degree of facial palsy was variable, most patients experienced a complete recovery without requiring any special treatment. DFP may be a self-healing disease that resolves spontaneously without any treatment. The time of onset was correlated with the duration of DFP; i.e., an earlier development of DFP corresponded with a shorter duration, whereas a later development of DFP corresponded with a longer duration. Our results also suggest that hypertension contributes to DFP.