Christopher J. Tucker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christopher J. Tucker has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Conor F. McCarthy
Department of Orthopaedic Surgery, Walter Reed National Military Medical Center, Bethesda, MD, USA
2 shared publications - Donald F. Colantonio
Uniformed Services University of Health Sciences , Bethesda, MD 20814
2 shared publications - Andrew J. Sheean
San Antonio Military Medical Center
1 shared publication - Benjamin W. Hoyt
Department of Orthopaedic Surgery, Captain James A. Lovell Federal Health Care Center, North Chicago, Illinois, USA
1 shared publication - Brett D. Owens
Brown University, Providence, Rhode Island
1 shared publication Carol Mohler
The Dow Chemical Company, Core R&D, Midland, Michigan 48674, United States
1 shared publication
Latest Publications
- Open Access
- 18 February 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (2)
Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction
Background: Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established. Purpose/Hypothesis: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft. Study Design: Controlled laboratory study. Methods: A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10–mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6–mm wide or 8–mm wide full-thickness QT along with a 10–mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure. Results: The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT ( P = .004), 10-mm and 6-mm QT ( P < .001), 10-mm QT and 10-mm PT ( P < .001), and 8-mm QT and 10-mm PT grafts ( P < .001), but not between the 6-mm QT and 10-mm PT grafts ( P = .152). Conclusion: The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts <10 mm in width may maintain sufficient tensile strength for ACLR. Clinical Relevance: Given these biomechanical properties, smaller QT graft sizes may be advantageous in minimizing arthrofibrosis risk while maintaining graft strength.
- 18 February 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (2)
Open AccessSmaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction
Background: Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established. Purpose/Hypothesis: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft. Study Design: Controlled laboratory study. Methods: A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10–mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6–mm wide or 8–mm wide full-thickness QT along with a 10–mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure. Results: The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT ( P = .004), 10-mm and 6-mm QT ( P < .001), 10-mm QT and 10-mm PT ( P < .001), and 8-mm QT and 10-mm PT grafts ( P < .001), but not between the 6-mm QT and 10-mm PT grafts ( P = .152). Conclusion: The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts <10 mm in width may maintain sufficient tensile strength for ACLR. Clinical Relevance: Given these biomechanical properties, smaller QT graft sizes may be advantageous in minimizing arthrofibrosis risk while maintaining graft strength.
- 20 June 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (2) , 484-490
Effect of surgery setting for outpatient shoulder procedures on early postoperative complications in a military population
- 20 June 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (2) , 484-490
Effect of surgery setting for outpatient shoulder procedures on early postoperative complications in a military population
- Open Access
- 14 June 2024
- Published by Wiley in Arthroscopy Techniques
- Vol. 13 (10) , 103072
Revision Meniscal Repair With Amniotic Membrane Augmentation
Meniscal injury is common, and despite modern techniques, the failure rate following repair remains high. While there are recent treatment advances in the form of biologics, there is limited evidence and agreement on these emerging therapies and their role in meniscal healing. Amniotic tissue (umbilical cord allograft) is a biologic augmentation therapy that has been utilized in other musculoskeletal applications but has not been reported for use in meniscal repair. We describe a technique to deliver an allograft amniotic membrane into a meniscus tear repair site, potentially optimizing healing. Technique Video: video See video under supplementary data.
- 14 June 2024
- Published by Wiley in Arthroscopy Techniques
- Vol. 13 (10) , 103072
Open AccessRevision Meniscal Repair With Amniotic Membrane Augmentation
Meniscal injury is common, and despite modern techniques, the failure rate following repair remains high. While there are recent treatment advances in the form of biologics, there is limited evidence and agreement on these emerging therapies and their role in meniscal healing. Amniotic tissue (umbilical cord allograft) is a biologic augmentation therapy that has been utilized in other musculoskeletal applications but has not been reported for use in meniscal repair. We describe a technique to deliver an allograft amniotic membrane into a meniscus tear repair site, potentially optimizing healing. Technique Video: video See video under supplementary data.
- 5 May 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (19) , 6180-6190
Molecular Interactions between Amino Silane Adhesion Promoter and Acrylic Polymer Adhesive at Buried Silica Interfaces
In this study, the influence of an amino silane (3-(2-aminoethylamino)-propyldimethoxymethylsilane, AEAPS) on the interfacial structure and adhesion of butyl acrylate/methyl methacrylate copolymers (BAMMAs) to silica was investigated by sum frequency generation vibrational spectroscopy (SFG). Small amounts of methacrylic acid, MAA, were included in the BAMMA polymerizations to assess the impact of carboxylic acid functionality on the glass interface. SFG was used to probe the O-H and C═O groups of incorporated MAA, ester C═O groups of BAMMA, and CH groups from all species at the silica interfaces. The addition of AEAPS resulted in a significant change in the molecular structure of the polymer at the buried interface with silica due to specific interactions between the BAMMA polymers and silane. SFG results were consistent with the formation of ionic bonds between the primary and secondary amines of the AEAPS tail group and the MAA component of the polymer, as evidenced by the loss of the MAA O-H and C═O signals at the interface. It is extensively reported in the literature that methoxy head groups of an amino silane chemically bind to the silanols of glass, leaving the amine groups available to react with various chemical functionalities. Our results are consistent with this scenario and support an adhesion promotion mechanism of amino silane with various aspects: (1) the ionic bond formation between the tail amine group and acid functionality on BAMMA, (2) the chemical coupling between the silane head group and glass, (3) migration of more ester C═O groups to the interface with order, and (4) disordering or reduced levels of CH groups at the interface. These results are important for better understanding of the mechanisms and effect of amino silanes on the adhesion between acrylate polymers and glass substrates in a variety of applications.
- 5 May 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (19) , 6180-6190
Molecular Interactions between Amino Silane Adhesion Promoter and Acrylic Polymer Adhesive at Buried Silica Interfaces
In this study, the influence of an amino silane (3-(2-aminoethylamino)-propyldimethoxymethylsilane, AEAPS) on the interfacial structure and adhesion of butyl acrylate/methyl methacrylate copolymers (BAMMAs) to silica was investigated by sum frequency generation vibrational spectroscopy (SFG). Small amounts of methacrylic acid, MAA, were included in the BAMMA polymerizations to assess the impact of carboxylic acid functionality on the glass interface. SFG was used to probe the O-H and C═O groups of incorporated MAA, ester C═O groups of BAMMA, and CH groups from all species at the silica interfaces. The addition of AEAPS resulted in a significant change in the molecular structure of the polymer at the buried interface with silica due to specific interactions between the BAMMA polymers and silane. SFG results were consistent with the formation of ionic bonds between the primary and secondary amines of the AEAPS tail group and the MAA component of the polymer, as evidenced by the loss of the MAA O-H and C═O signals at the interface. It is extensively reported in the literature that methoxy head groups of an amino silane chemically bind to the silanols of glass, leaving the amine groups available to react with various chemical functionalities. Our results are consistent with this scenario and support an adhesion promotion mechanism of amino silane with various aspects: (1) the ionic bond formation between the tail amine group and acid functionality on BAMMA, (2) the chemical coupling between the silane head group and glass, (3) migration of more ester C═O groups to the interface with order, and (4) disordering or reduced levels of CH groups at the interface. These results are important for better understanding of the mechanisms and effect of amino silanes on the adhesion between acrylate polymers and glass substrates in a variety of applications.
- 20 April 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (9) , 2352-2353
Subpectoral Biceps Tenodesis of the Shoulder: Indications and Technique Options
Subpectoral biceps tenodesis of the shoulder may be a useful tool that can address a wide range of disorders in the setting of pathology of the long head of the biceps tendon. Primary indications include (1) zone 2 or zone 3 tendon pathology and (2) failed previous proximal tendon tenodesis. Secondary indications include (1) an overhead athlete or thrower, (2) chronic tendinopathy, and (3) surgeon preference. A subpectoral technique allows tendon fixation directly posterior (deep) to the pectoralis tendon high in the bicipital fossa or in the mid fossa or fixation low in the fossa inferior to the pectoralis tendon (infrapectoral). Fixation technique options include an onlay suture anchor, onlay unicortical button, inlay bicortical button, or inlay interference screw. Potential surgical complications include humeral fracture, loss of fixation, tendon pullout or rupture, and neurovascular injury. Regardless of the specific location or technique used, subpectoral tenodesis is a valuable tool for the treatment of proximal biceps tendon pathology.
- 20 April 2020
- Published by Wiley in Arthroscopy
- Vol. 36 (9) , 2352-2353
Subpectoral Biceps Tenodesis of the Shoulder: Indications and Technique Options
Subpectoral biceps tenodesis of the shoulder may be a useful tool that can address a wide range of disorders in the setting of pathology of the long head of the biceps tendon. Primary indications include (1) zone 2 or zone 3 tendon pathology and (2) failed previous proximal tendon tenodesis. Secondary indications include (1) an overhead athlete or thrower, (2) chronic tendinopathy, and (3) surgeon preference. A subpectoral technique allows tendon fixation directly posterior (deep) to the pectoralis tendon high in the bicipital fossa or in the mid fossa or fixation low in the fossa inferior to the pectoralis tendon (infrapectoral). Fixation technique options include an onlay suture anchor, onlay unicortical button, inlay bicortical button, or inlay interference screw. Potential surgical complications include humeral fracture, loss of fixation, tendon pullout or rupture, and neurovascular injury. Regardless of the specific location or technique used, subpectoral tenodesis is a valuable tool for the treatment of proximal biceps tendon pathology.
- 1 November 2011
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 22 (6) , 474-482
Surgical management of posterior shoulder instability
Posterior glenohumeral joint instability is becoming increasingly recognized. Subluxations are predominant, but true dislocations can occur. Patients typically present with pain with provocative activity and may or may not have a sensation of instability. A fall onto an outstretched hand or elbow is a classic traumatic mechanism, while bench press and pushups are bothersome in chronic cases. Advances in physical examination and diagnostic imaging modalities have improved the ability to identify the lesions associated with posterior instability. While physical therapy remains the mainstay of initial management, surgical stabilization is required if conservative means are unsuccessful in an active patient. Outcomes of arthroscopic labral repair either with or without capsular plication have been good to excellent in recent mid-term follow-up studies. While these studies are promising, longer-term studies are needed to determine the durability of this surgical management technique. While most patients with posterior glenohumeral joint instability can be treated arthroscopically, certain conditions (bone loss, significant glenoid retroversion, revision, etc) may be best managed through an open approach.
- 1 November 2011
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 22 (6) , 474-482
Surgical management of posterior shoulder instability
Posterior glenohumeral joint instability is becoming increasingly recognized. Subluxations are predominant, but true dislocations can occur. Patients typically present with pain with provocative activity and may or may not have a sensation of instability. A fall onto an outstretched hand or elbow is a classic traumatic mechanism, while bench press and pushups are bothersome in chronic cases. Advances in physical examination and diagnostic imaging modalities have improved the ability to identify the lesions associated with posterior instability. While physical therapy remains the mainstay of initial management, surgical stabilization is required if conservative means are unsuccessful in an active patient. Outcomes of arthroscopic labral repair either with or without capsular plication have been good to excellent in recent mid-term follow-up studies. While these studies are promising, longer-term studies are needed to determine the durability of this surgical management technique. While most patients with posterior glenohumeral joint instability can be treated arthroscopically, certain conditions (bone loss, significant glenoid retroversion, revision, etc) may be best managed through an open approach.