Hao Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hao Hu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Yunxiao Zhang
College of Electrical Engineering and Automation Fuzhou University Fuzhou Fujian China
11 shared publications - Yuhao Liu
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, Fujian, China
10 shared publications - Zhidong Jia
Tsinghua Shenzhen International Graduate School Tsinghua University Shenzhen China
8 shared publications Weinan Fan
Guangzhou Power Supply, China Southern Power Grid Company Ltd., Guangzhou, Guangdong, China
4 shared publicationsYuhao Liu
College of Electrical Engineering and Automation Fuzhou University Fuzhou China
3 shared publications- Bin Cao
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, People’s Republic of China
2 shared publications
Latest Publications
- 29 July 2026
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 143 (39)
Electrical Tree Degradation of Silicone Rubber Considering the Effects of Solution Conditions
In addition to electrothermal stresses, cable systems face significant degradation from environmental factors like moisture and nitric acid during long‐term operation. This study systematically examines how long‐term immersion (1000 h) in deionized water and 0.1 mol/L nitric acid influences the electrical performance of silicone rubber (SiR) used in cable accessories, focusing on AC electrical treeing characteristics and space charge behavior. The results reveal a clear dichotomy: water immersion raises the tree initiation voltage, slows tree growth, and induces homo‐charge accumulation, whereas nitric acid immersion lowers the initiation voltage, accelerates tree growth, and promotes hetero‐charge accumulation. Molecular modeling and orbital‐energy calculations for three aging states further clarify the role of different immersion treatments in tree initiation. Supported by physicochemical characterization, we demonstrate that nitric acid causes oxidative degradation of the SiR network, increasing the density of physical weak regions and fostering the growth of pine‐branch‐like trees with distinct main channels. Notably, moisture incorporation is found to counterintuitively enhance certain tree‐resistance properties of the silicone rubber, offering fresh insight for material design in humid environments.
- 29 July 2026
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 143 (39)
Electrical Tree Degradation of Silicone Rubber Considering the Effects of Solution Conditions
In addition to electrothermal stresses, cable systems face significant degradation from environmental factors like moisture and nitric acid during long‐term operation. This study systematically examines how long‐term immersion (1000 h) in deionized water and 0.1 mol/L nitric acid influences the electrical performance of silicone rubber (SiR) used in cable accessories, focusing on AC electrical treeing characteristics and space charge behavior. The results reveal a clear dichotomy: water immersion raises the tree initiation voltage, slows tree growth, and induces homo‐charge accumulation, whereas nitric acid immersion lowers the initiation voltage, accelerates tree growth, and promotes hetero‐charge accumulation. Molecular modeling and orbital‐energy calculations for three aging states further clarify the role of different immersion treatments in tree initiation. Supported by physicochemical characterization, we demonstrate that nitric acid causes oxidative degradation of the SiR network, increasing the density of physical weak regions and fostering the growth of pine‐branch‐like trees with distinct main channels. Notably, moisture incorporation is found to counterintuitively enhance certain tree‐resistance properties of the silicone rubber, offering fresh insight for material design in humid environments.
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Reconstruction of curing temperature field evolution in epoxy composite insulators based on sparse monitoring data and reduced order modeling
Non-uniform temperature distribution during epoxy resin curing is a primary source of internal stress development. However, existing experimental techniques cannot capture the global evolution of internal temperature fields, while conventional numerical simulations are challenged by strong coupling among material properties, temperature, and degree of cure. In this work, a global reconstruction model for curing temperature fields is developed for cycloaliphatic epoxy insulators based on sparse monitoring data and reduced-order modeling. The reconstruction accuracy and generalization capability of the proposed model are systematically evaluated. The results confirm that the proposed model enables accurate reconstruction of the curing temperature field evolution, with a reconstruction time of less than 0.05 ms. Reconstruction accuracy improves with increasing numbers of monitoring points and snapshots, although the improvement gradually saturates. Further improvements are achieved through optimized snapshot selection and reduced monitoring errors. The model developed at 130 °C successfully predicts temperature fields at lower curing temperatures with a maximum error below 1.6 °C, and maintains errors within 2.6 °C for epoxy systems exhibiting different curing kinetics. Higher curing temperatures yield more diverse thermal field characteristics, resulting in improved generalization performance. This work establishes a global curing temperature field reconstruction strategy, providing a quantitative foundation for enhancing the reliability of epoxy composite manufacturing.
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Reconstruction of curing temperature field evolution in epoxy composite insulators based on sparse monitoring data and reduced order modeling
Non-uniform temperature distribution during epoxy resin curing is a primary source of internal stress development. However, existing experimental techniques cannot capture the global evolution of internal temperature fields, while conventional numerical simulations are challenged by strong coupling among material properties, temperature, and degree of cure. In this work, a global reconstruction model for curing temperature fields is developed for cycloaliphatic epoxy insulators based on sparse monitoring data and reduced-order modeling. The reconstruction accuracy and generalization capability of the proposed model are systematically evaluated. The results confirm that the proposed model enables accurate reconstruction of the curing temperature field evolution, with a reconstruction time of less than 0.05 ms. Reconstruction accuracy improves with increasing numbers of monitoring points and snapshots, although the improvement gradually saturates. Further improvements are achieved through optimized snapshot selection and reduced monitoring errors. The model developed at 130 °C successfully predicts temperature fields at lower curing temperatures with a maximum error below 1.6 °C, and maintains errors within 2.6 °C for epoxy systems exhibiting different curing kinetics. Higher curing temperatures yield more diverse thermal field characteristics, resulting in improved generalization performance. This work establishes a global curing temperature field reconstruction strategy, providing a quantitative foundation for enhancing the reliability of epoxy composite manufacturing.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electrical tree inhibition characteristics of AOS grafted epoxy resin composites considering the coupling effects of high frequency and temperature
Encapsulation insulation materials for high-frequency transformers endure coupled electrothermal stresses from sustained high-frequency pulsed voltages and elevated operational temperatures, exhibiting inherent limitations in electrical treeing resistance that trigger premature insulation degradation. To address this, 4-acetoxystyrene (AOS) is chemically grafted onto E-51 bisphenol-A epoxy resin (DGEBA) via free radical grafting, forming DGEBA-g-AOS composites with varied AOS contents. The electrical tree growth characteristics under high-frequency (10 kHz) conditions at both room temperature (25°C) and high temperature (90°C) are systematically investigated through physicochemical characterization, quantum chemical calculations, and trap property analysis. The results demonstrate that at 25°C and 10 kHz, AOS effectively delays electrical tree initiation and propagation by trapping high-energy electrons and increasing trap density. Under 90°C and 10 kHz conditions, although the electrical tree growth rate shows no significant reduction, branch complexity decreases, and the damage area diminishes. This study provides critical insights for the development of advanced encapsulation insulation materials in high-frequency/high-temperature transformers.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electrical tree inhibition characteristics of AOS grafted epoxy resin composites considering the coupling effects of high frequency and temperature
Encapsulation insulation materials for high-frequency transformers endure coupled electrothermal stresses from sustained high-frequency pulsed voltages and elevated operational temperatures, exhibiting inherent limitations in electrical treeing resistance that trigger premature insulation degradation. To address this, 4-acetoxystyrene (AOS) is chemically grafted onto E-51 bisphenol-A epoxy resin (DGEBA) via free radical grafting, forming DGEBA-g-AOS composites with varied AOS contents. The electrical tree growth characteristics under high-frequency (10 kHz) conditions at both room temperature (25°C) and high temperature (90°C) are systematically investigated through physicochemical characterization, quantum chemical calculations, and trap property analysis. The results demonstrate that at 25°C and 10 kHz, AOS effectively delays electrical tree initiation and propagation by trapping high-energy electrons and increasing trap density. Under 90°C and 10 kHz conditions, although the electrical tree growth rate shows no significant reduction, branch complexity decreases, and the damage area diminishes. This study provides critical insights for the development of advanced encapsulation insulation materials in high-frequency/high-temperature transformers.
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
A weakness breakdown model of a BOPP film based on blister growth under cyclic pulsed voltage
The investigation of failure mechanisms in thin-film materials has consistently been a critical aspect of ensuring the reliability of energy storage devices. In this study, full-lifecycle pulsed electrical aging tests were conducted on biaxially oriented polypropylene (BOPP) films. Experimental results reveal that the blisters formed on the surface of electrically aged BOPP films are cavity-structured bubbles, which essentially represent a distinct form of “latent electrical weakness” arising from irreversible material degradation under multi-field electro–thermo–mechanical coupling. Furthermore, a physical model and equivalent impedance were established for these bubbles, providing additional evidence that the blisters play a decisive role in the degradation of the breakdown performance of BOPP films.
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
A weakness breakdown model of a BOPP film based on blister growth under cyclic pulsed voltage
The investigation of failure mechanisms in thin-film materials has consistently been a critical aspect of ensuring the reliability of energy storage devices. In this study, full-lifecycle pulsed electrical aging tests were conducted on biaxially oriented polypropylene (BOPP) films. Experimental results reveal that the blisters formed on the surface of electrically aged BOPP films are cavity-structured bubbles, which essentially represent a distinct form of “latent electrical weakness” arising from irreversible material degradation under multi-field electro–thermo–mechanical coupling. Furthermore, a physical model and equivalent impedance were established for these bubbles, providing additional evidence that the blisters play a decisive role in the degradation of the breakdown performance of BOPP films.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electrical Treeing Resistance in Epoxy Resins with Varied Molecular Structures Under High-Frequency and High-Temperature Conditions
As power electronics evolve towards high-frequency and high-power-density applications, conventional epoxy resin encapsulation materials face critical challenges in withstanding the combined stresses of high-frequency pulse-width modulation voltages and elevated operating temperatures, posing substantial threats to system reliability. The relationship between the molecular structure of epoxy resins and their resistance to electrical treeing remains unclear. This study systematically evaluates the electrical treeing resistance of four commercially available epoxy resins with distinct molecular architectures under high-frequency (10 kHz) and high-temperature (90 °C) conditions. Through isothermal surface potential decay (ISPD) tests and quantum chemical calculations, we elucidate the mechanism of electrical treeing inhibition from microscopic perspectives of electron cloud polarization and trap distribution characteristics. Results demonstrate that densely distributed shallow traps in epoxy resins promote bush-like electrical tree growth patterns, homogenizing internal electric field and effectively suppressing tree propagation. This work establishes a theoretical framework for designing and evaluating insulation materials in high-frequency/high-temperature power electronic systems.
- 25 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electrical Treeing Resistance in Epoxy Resins with Varied Molecular Structures Under High-Frequency and High-Temperature Conditions
As power electronics evolve towards high-frequency and high-power-density applications, conventional epoxy resin encapsulation materials face critical challenges in withstanding the combined stresses of high-frequency pulse-width modulation voltages and elevated operating temperatures, posing substantial threats to system reliability. The relationship between the molecular structure of epoxy resins and their resistance to electrical treeing remains unclear. This study systematically evaluates the electrical treeing resistance of four commercially available epoxy resins with distinct molecular architectures under high-frequency (10 kHz) and high-temperature (90 °C) conditions. Through isothermal surface potential decay (ISPD) tests and quantum chemical calculations, we elucidate the mechanism of electrical treeing inhibition from microscopic perspectives of electron cloud polarization and trap distribution characteristics. Results demonstrate that densely distributed shallow traps in epoxy resins promote bush-like electrical tree growth patterns, homogenizing internal electric field and effectively suppressing tree propagation. This work establishes a theoretical framework for designing and evaluating insulation materials in high-frequency/high-temperature power electronic systems.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3764-3767
Accurate Evaluation of Interfacial Pressure in Cable Accessories Subject to Nonhomogeneous Degradation
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3764-3767
Accurate Evaluation of Interfacial Pressure in Cable Accessories Subject to Nonhomogeneous Degradation
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Dual-Stage Optimization for Cable Fault Localization Wavelet Adaptive Denoising and PSO-GA Hybrid Windowing
To address the challenges of “pseudo-peak” misjudgment rates in broadband impedance spectroscopy-based cable fault localization, this paper proposes a dual-stage optimization method integrating wavelet adaptive denoising with particle swarm-genetic hybrid windowing. The study first introduces a wavelet adaptive denoising algorithm based on multi-scale noise variance dynamic estimation, which combines the Garrote threshold function to directionally filter high-frequency noise. This approach preserves impedance mutation features while significantly enhancing the signal-to-noise ratio and reducing mean square error. Subsequently, a PSO-GA hybrid intelligent windowing algorithm is designed, dynamically optimizing the Kaiser window’s main lobe width and side lobe attenuation factor by integrating the rapid convergence of particle swarm optimization with the global search capability of genetic algorithms, thereby overcoming the limitations of traditional window functions in high-frequency resolution. Simulations and experiments demonstrate that the proposed method improves the localization peak by three times and optimizes localization accuracy to one-third of the original in single-defect scenarios, achieving optimal mean square error and signal-to-noise ratio. In multi-defect scenarios, all metrics outperform traditional algorithms, significantly enhancing robustness and localization accuracy in complex noise environments.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Dual-Stage Optimization for Cable Fault Localization Wavelet Adaptive Denoising and PSO-GA Hybrid Windowing
To address the challenges of “pseudo-peak” misjudgment rates in broadband impedance spectroscopy-based cable fault localization, this paper proposes a dual-stage optimization method integrating wavelet adaptive denoising with particle swarm-genetic hybrid windowing. The study first introduces a wavelet adaptive denoising algorithm based on multi-scale noise variance dynamic estimation, which combines the Garrote threshold function to directionally filter high-frequency noise. This approach preserves impedance mutation features while significantly enhancing the signal-to-noise ratio and reducing mean square error. Subsequently, a PSO-GA hybrid intelligent windowing algorithm is designed, dynamically optimizing the Kaiser window’s main lobe width and side lobe attenuation factor by integrating the rapid convergence of particle swarm optimization with the global search capability of genetic algorithms, thereby overcoming the limitations of traditional window functions in high-frequency resolution. Simulations and experiments demonstrate that the proposed method improves the localization peak by three times and optimizes localization accuracy to one-third of the original in single-defect scenarios, achieving optimal mean square error and signal-to-noise ratio. In multi-defect scenarios, all metrics outperform traditional algorithms, significantly enhancing robustness and localization accuracy in complex noise environments.