MCMihai Culea

Mihai Culea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mihai Culea has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Adriana Burlibasa

    Department of Electrical Engineering and Energy Conversion Systems, Faculty of Automation, Computers, Electrical and Electronics Engineering, “Dunărea de Jos” University of Galati, 800008 Galati, Romania

    1 shared publication
  • Anisia Florescu

    Research Center for Electronics, Information Technology and Communications, Faculty of Automation, Computers, Electrical and Electronic Engineering, “Dunarea de Jos” University of Galați, 800201 Galați, Romania

    1 shared publication
  • Bogdan Ioan Ștefănescu

    Faculty of Medicine and Pharmacy, Research Center in the Medical-Pharmaceutical Field, “Dunarea de Jos” University of Galati, 800008 Galati, Romania

    1 shared publication
  • Ciprian Vlad

    Department of Electrical Engineering and Energy Conversion Systems, Faculty of Automation, Computers, Electrical and Electronics Engineering, Dunarea de Jos University of Galati, 800008 Galati, Romania

    1 shared publication
  • Cristian Victor Lungu

    Department of Electrical Engineering and Energy Conversion Systems, Faculty of Automation, Computers, Electrical and Electronics Engineering, Dunarea de Jos University of Galati, 800008 Galati, Romania

    1 shared publication
  • Cristinel Radu Dache

    Department of Electrical Engineering and Energy Conversion Systems, Faculty of Automation, Computers, Electrical and Electronics Engineering, “Dunărea de Jos” University of Galati, 800008 Galati, Romania

    1 shared publication

Latest Publications

  • Open Access

    System-Level Offline Time Synchronization Architecture for Distributed Electrical Signal Monitoring Using Raspberry Pi 5

    by Adriana Burlibaşa, Silviu Epure, Mihai Culea, Cristinel Radu Dache, Cristian Victor Lungu, George-Andrei Marin, Ciprian Vlad

    Accurate time synchronization is essential in distributed electrical signal monitoring, where phase coherence and event correlation depend on precise timing agreement between acquisition nodes. Conventional approaches often rely on a single synchronization source, typically internet-based Network Time Protocol (NTP) or GPS-disciplined clocks, which is impractical in isolated, offline, or cost-sensitive scenarios. This paper introduces an autonomous offline synchronization architecture for multi-node monitoring systems built on Raspberry Pi 5 (RPI5) platforms connected to a private Ethernet network. Instead of depending on one timing method, the system integrates several complementary mechanisms: battery-backed RTC persistence via the J5 interface, deterministic orchestration through systemd services, automated boot time recovery, chrony-managed NTP discipline, and Precision Time Protocol (PTP) hardware timestamping using PTP Hardware Clock (PHC). Synchronization performance is validated through continuous multi-day measurements of long-term stability, inter-node phase coherence, and short-term jitter. Controlled power-loss scenarios are also included to verify recovery behavior. The system maintains sub-microsecond alignment between nodes using only commodity hardware and no external time source. To further confirm inter-node timestamp alignment at the signal level, both hardware-based reference signal injection and software-based synchronized signal emulation are employed, providing ground-truth validation alongside scalable and reproducible evaluation. The results show that low-cost embedded hardware can support reliable, long-duration synchronization in fully offline installations.

  • Open Access

    A New Approach in Detectability of Microcalcifications in the Placenta during Pregnancy Using Textural Features and K-Nearest Neighbors Algorithm

    by Mihaela Miron, Simona Moldovanu, Bogdan Ioan Ștefănescu, Mihai Culea, Sorin Marius Pavel, Anisia Luiza Culea-Florescu

    (1) Background: Ultrasonography is the main method used during pregnancy to assess the fetal growth, amniotic fluid, umbilical cord and placenta. The placenta’s structure suffers dynamic modifications throughout the whole pregnancy and many of these changes, in which placental microcalcifications are by far the most prominent, are related to the process of aging and maturation and have no effect on fetal wellbeing. However, when placental microcalcifications are noticed earlier during pregnancy, they could suggest a major placental dysfunction with serious consequences for the fetus and mother. For better detectability of microcalcifications, we propose a new approach based on improving the clarity of details and the analysis of the placental structure using first and second order statistics, and fractal dimension. (2) Methods: The methodology is based on four stages: (i) cropping the region of interest and preprocessing steps; (ii) feature extraction, first order—standard deviation (SD), skewness (SK) and kurtosis (KR)—and second order—contrast (C), homogeneity (H), correlation (CR), energy (E) and entropy (EN)—are computed from a gray level co-occurrence matrix (GLCM) and fractal dimension (FD); (iii) statistical analysis (t-test); (iv) classification with the K-Nearest Neighbors algorithm (K-NN algorithm) and performance comparison with results from the support vector machine algorithm (SVM algorithm). (3) Results: Experimental results obtained from real clinical data show an improvement in the detectability and visibility of placental microcalcifications.


  • A High Performance Harmonic Current Control for Shunt Active Filters Based on Resonant Compensators

    by Wanchak Lenwari, Mark Sumner, Pericle Zanchetta, Mihai Culea

    This paper proposes a very accurate harmonic current control for shunt active filters (SAF) using resonant compensators. The resonant control compensator based on sinusoidal internal model principle is introduced into the control system design in order to improve the control accuracy and performance for ac input signal. The proposed current control system is designed to operate with a single dq reference frame, synchronous with the 50 Hz supply voltage, for the compensation of all main harmonic currents, 5th, 7th, 11th and 13th. The principle of the proposed control method and the design procedure is presented. Experimental results confirm the accuracy and effectiveness of the suggested approach. Excellent harmonic current tracking performance can be achieved. Another major advantage of this strategy is the ability to eliminate the effect of an ac external disturbance from the harmonic components caused by the power supply