Yiwen Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yiwen Zheng has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Hongpeng Zhang
Dalian Maritime University
8 shared publications - Wei Li
Dalian Maritime University
6 shared publications - Yuqing Sun
Department of Marine Engineering, Dalian Maritime University, Dalian 116026, China
5 shared publications - Chenzhao Bai
College of Marine Engineering, Dalian Maritime University, Dalian 116026, China
3 shared publications - Guobin Li
Marine Engineering College, Dalian Maritime University, Dalian 116026, China
3 shared publications - Shuyao Zhang
Department of Internal Medicine/Endocrinology UT Southwestern Medical Center Dallas Texas USA
3 shared publications
Latest Publications
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Curved contraction–expansion channel design to improve particle separation performance of inertial microfluidic chips
As an efficient particle separation technology, an inertial microfluidic chip has broad application prospects in biomedicine, environmental monitoring, and other fields. This paper aims to explore the influence of the curve-contraction-expansion channel structure on the particle separation performance of the inertial microfluidic chip and optimize the chip design through numerical simulation methods. The principle of the inertial microfluidic chip is introduced, and the advantages and disadvantages of the curve channel, the contraction–expansion channel, and the combination of the two are analyzed. The simulation model of the inertial microfluidic chip is established, and the influence of parameters, such as the inlet angle, channel width, channel inner diameter and overall channel curvature on the particle separation performance, is analyzed. The research results show that the curve-contraction-expansion channel structure can effectively improve the particle separation performance. The particle separation effect is best when the inlet angle is 90°, the channel width is 30 μm, the channel inner diameter is 400 μm, and the overall channel curvature is 425 μm. In addition, the article also discusses the indicators, such as particle trajectory, yield, the change of the number of outlet particles over time, and the particle focusing effect, and analyzes the influence mechanism of different parameters on the separation performance. This paper provides a theoretical basis and reference for the optimal design of inertial microfluidic chips and looks forward to its application prospects in the biomedical field.
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Curved contraction–expansion channel design to improve particle separation performance of inertial microfluidic chips
As an efficient particle separation technology, an inertial microfluidic chip has broad application prospects in biomedicine, environmental monitoring, and other fields. This paper aims to explore the influence of the curve-contraction-expansion channel structure on the particle separation performance of the inertial microfluidic chip and optimize the chip design through numerical simulation methods. The principle of the inertial microfluidic chip is introduced, and the advantages and disadvantages of the curve channel, the contraction–expansion channel, and the combination of the two are analyzed. The simulation model of the inertial microfluidic chip is established, and the influence of parameters, such as the inlet angle, channel width, channel inner diameter and overall channel curvature on the particle separation performance, is analyzed. The research results show that the curve-contraction-expansion channel structure can effectively improve the particle separation performance. The particle separation effect is best when the inlet angle is 90°, the channel width is 30 μm, the channel inner diameter is 400 μm, and the overall channel curvature is 425 μm. In addition, the article also discusses the indicators, such as particle trajectory, yield, the change of the number of outlet particles over time, and the particle focusing effect, and analyzes the influence mechanism of different parameters on the separation performance. This paper provides a theoretical basis and reference for the optimal design of inertial microfluidic chips and looks forward to its application prospects in the biomedical field.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 9390-9400
Measurement of Lubricant Viscosity and Metal Particles Using Dual Coil Inductive Sensor
Lubricant is a critical component of a ship’s power plant, and analyzing the information on the change of lubricant viscosity and the wear particle it carries is of great significance to realize the condition monitoring of the power plant. In this paper, we propose and design an inductive sensor capable of simultaneously detecting the viscosity, particle diameter, and velocity of lubricants. COMSOL was used to investigate the magnetic field, particle flow, and particle velocity characteristics. The inductance signal amplitude and velocity values of spherical iron particles of eight diameters passing through four levels of viscosity lubricants were collected. Based on this data, we plotted the particle diameter-inductance signal amplitude curves, viscosity-velocity (for different diameters), and diameter-velocity (for different viscosities) curves. According to the experiment, when the two unknown iron particles passed through the standard oil sample of 50 mm 2 /s (20°C), the corresponding particle diameter can be obtained from the particle diameter-inductance amplitude curves as 300 μm and 278 μm, respectively. For the calibrated particle with a diameter of 300 μm, the viscosity-velocity (for different diameters) curve yielded the viscosity value of 53.382mm 2 /s with an error of 6.76%. The estimated viscosity value of 54.73 mm 2 /s was obtained by diameter-velocity (for different viscosity) curve for the non-calibrated particle of 278 μm, with an error of 9.46%. This detection technology provides a new research idea for marine lubricant testing.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 9390-9400
Measurement of Lubricant Viscosity and Metal Particles Using Dual Coil Inductive Sensor
Lubricant is a critical component of a ship’s power plant, and analyzing the information on the change of lubricant viscosity and the wear particle it carries is of great significance to realize the condition monitoring of the power plant. In this paper, we propose and design an inductive sensor capable of simultaneously detecting the viscosity, particle diameter, and velocity of lubricants. COMSOL was used to investigate the magnetic field, particle flow, and particle velocity characteristics. The inductance signal amplitude and velocity values of spherical iron particles of eight diameters passing through four levels of viscosity lubricants were collected. Based on this data, we plotted the particle diameter-inductance signal amplitude curves, viscosity-velocity (for different diameters), and diameter-velocity (for different viscosities) curves. According to the experiment, when the two unknown iron particles passed through the standard oil sample of 50 mm 2 /s (20°C), the corresponding particle diameter can be obtained from the particle diameter-inductance amplitude curves as 300 μm and 278 μm, respectively. For the calibrated particle with a diameter of 300 μm, the viscosity-velocity (for different diameters) curve yielded the viscosity value of 53.382mm 2 /s with an error of 6.76%. The estimated viscosity value of 54.73 mm 2 /s was obtained by diameter-velocity (for different viscosity) curve for the non-calibrated particle of 278 μm, with an error of 9.46%. This detection technology provides a new research idea for marine lubricant testing.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
A high sensitivity cross-capacitive sensor for water droplets and bubble detection in hydraulic oil
The presence of moisture and air in hydraulic oil will seriously affect the reliability of machines. This paper proposes a new cross-capacitive oil pollution detection sensor, which is based on the Thompson and Lampard theorem. The sensing unit consists of four identical copper electrodes with infinitesimally small gaps. The sensor can effectively distinguish water droplets and air bubble pollutants mixed in the oil through the pulse direction of the signal. Compared with traditional capacitive sensors, the sensor has a significant improvement in detection accuracy and detection throughput. In this paper, the relationship between the cross-capacitance value with the dielectric constant and the frequency in an alternating electric field was deduced, and the best excitation frequency was chosen as 1.9 MHz. Experiments show that the sensor can effectively detect water droplets of 140–160 µm and bubbles of 170–190 µm and has good linearity for detecting water droplets and air bubbles of different sizes. The sensor provides a new method for machine condition monitoring of hydraulic systems.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
A high sensitivity cross-capacitive sensor for water droplets and bubble detection in hydraulic oil
The presence of moisture and air in hydraulic oil will seriously affect the reliability of machines. This paper proposes a new cross-capacitive oil pollution detection sensor, which is based on the Thompson and Lampard theorem. The sensing unit consists of four identical copper electrodes with infinitesimally small gaps. The sensor can effectively distinguish water droplets and air bubble pollutants mixed in the oil through the pulse direction of the signal. Compared with traditional capacitive sensors, the sensor has a significant improvement in detection accuracy and detection throughput. In this paper, the relationship between the cross-capacitance value with the dielectric constant and the frequency in an alternating electric field was deduced, and the best excitation frequency was chosen as 1.9 MHz. Experiments show that the sensor can effectively detect water droplets of 140–160 µm and bubbles of 170–190 µm and has good linearity for detecting water droplets and air bubbles of different sizes. The sensor provides a new method for machine condition monitoring of hydraulic systems.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
An Asymmetric Micro-Three-Coil Sensor Enabling Non-Ferrous Metals Distinguishment
At present, when performing material identification of metal wear debris, most sensors can only roughly distinguish between ferromagnetic and non- ferromagnetic metal wear debris, but fail to distinguish them deeply. To achieve fine detection of metal wear debris in the oil, this paper designs an asymmetric micro-three-coil sensor, which generates an asymmetric magnetic field by using two excitation coils of different sizes. Different metal wear debris are affected differently in the magnetic field and the shape of the output signal is also different, therefore, the wear debris material can be distinguished by the shape of the signal of the induction electric potential output from the induction coil alone, and the wear debris size can be determined by the amplitude of the signal. Copper particles, aluminum particles, iron particles and 304 stainless steel particles were selected as experimental objects, and the experimental results showed that the material differentiation of these four types of particles can be achieved by the asymmetric magnetic field of the sensor. The method provides a new research direction for the inductive method to distinguish non-ferrous metals, which is important for the fine detection of multi-parameter pollutants and the diagnosis and monitoring of mechanical system faults.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
An Asymmetric Micro-Three-Coil Sensor Enabling Non-Ferrous Metals Distinguishment
At present, when performing material identification of metal wear debris, most sensors can only roughly distinguish between ferromagnetic and non- ferromagnetic metal wear debris, but fail to distinguish them deeply. To achieve fine detection of metal wear debris in the oil, this paper designs an asymmetric micro-three-coil sensor, which generates an asymmetric magnetic field by using two excitation coils of different sizes. Different metal wear debris are affected differently in the magnetic field and the shape of the output signal is also different, therefore, the wear debris material can be distinguished by the shape of the signal of the induction electric potential output from the induction coil alone, and the wear debris size can be determined by the amplitude of the signal. Copper particles, aluminum particles, iron particles and 304 stainless steel particles were selected as experimental objects, and the experimental results showed that the material differentiation of these four types of particles can be achieved by the asymmetric magnetic field of the sensor. The method provides a new research direction for the inductive method to distinguish non-ferrous metals, which is important for the fine detection of multi-parameter pollutants and the diagnosis and monitoring of mechanical system faults.
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
An Oil Multipollutant Detection Sensor With High Sensitivity and High Throughput
Oil is rich in information about the operating status of machinery and equipment, and oil condition monitoring is essential for maintaining the safety and reliability of machinery and equipment. Most sensors not only have the problem of small detection throughput and low detection efficiency, but also large-sized contaminants can easily block or even scratch the detection channel. A sensor with high sensitivity and high throughput for detecting multiple oil contamination is designed in this article. The sensor comprises four glass capillary detection channels and four detection units, including a planar coil, solenoid coil, cylindrical parallel plate capacitor, and rectangular parallel plate capacitor. Detection flux of the sensor is increased by 12 times its initial value, which significantly improves the detection efficiency. Through experimental research, in the inductance mode, the best excitation frequency is 2 MHz, and the voltage is 2 V. In the capacitance mode, the best excitation frequency is 1.8 MHz, and the voltage is 2 V. In addition, the sensor has a higher detection capability for Fe than Cu in the inductance mode, and a higher detection capability for water droplets than air bubbles in the capacitance mode. By analyzing the signal characteristics of each sensor unit, the sensor can distinguish between Fe of 38– $900 ~\mu \text{m}$ and Cu of 88– $900 ~\mu \text{m}$ , as well as water droplets greater than $130 ~\mu \text{m}$ and air bubbles greater than $100 ~\mu \text{m}$ . This research provides a new idea for online oil monitoring.
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
An Oil Multipollutant Detection Sensor With High Sensitivity and High Throughput
Oil is rich in information about the operating status of machinery and equipment, and oil condition monitoring is essential for maintaining the safety and reliability of machinery and equipment. Most sensors not only have the problem of small detection throughput and low detection efficiency, but also large-sized contaminants can easily block or even scratch the detection channel. A sensor with high sensitivity and high throughput for detecting multiple oil contamination is designed in this article. The sensor comprises four glass capillary detection channels and four detection units, including a planar coil, solenoid coil, cylindrical parallel plate capacitor, and rectangular parallel plate capacitor. Detection flux of the sensor is increased by 12 times its initial value, which significantly improves the detection efficiency. Through experimental research, in the inductance mode, the best excitation frequency is 2 MHz, and the voltage is 2 V. In the capacitance mode, the best excitation frequency is 1.8 MHz, and the voltage is 2 V. In addition, the sensor has a higher detection capability for Fe than Cu in the inductance mode, and a higher detection capability for water droplets than air bubbles in the capacitance mode. By analyzing the signal characteristics of each sensor unit, the sensor can distinguish between Fe of 38– $900 ~\mu \text{m}$ and Cu of 88– $900 ~\mu \text{m}$ , as well as water droplets greater than $130 ~\mu \text{m}$ and air bubbles greater than $100 ~\mu \text{m}$ . This research provides a new idea for online oil monitoring.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Capacitive–Inductive Magnetic Plug Sensor With High Adaptability for Online Debris Monitoring
A capacitive–inductive magnetic plug sensor for online condition monitoring is proposed in this article, which can achieve particle counting, debris measurement, and wear rate estimation. The sensor can detect capacitance and inductance parameters, the coil is the outer electrode to detect the dielectric change in capacitance mode, and the coil directly induces magnetic field disturbance in inductance mode. Through introducing a reference unit, Wheatstone bridge circuits are constructed to enhance the response to debris and reduce the interference of oil temperature and viscosity. A postprocessing circuit with filtering and amplifying functions is adopted to improve accuracy. The sensor output characteristics and debris position effect are studied through the experiment. The comprehensive analysis of the detection results in two modes can improve sensor adaptability and overcome the deficiency of low reliability based on a single detection method. This sensor can provide more accurate debris information for the fault diagnosis of hydraulic equipment and is of great significance for intelligent maintenance.
- 10 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Capacitive–Inductive Magnetic Plug Sensor With High Adaptability for Online Debris Monitoring
A capacitive–inductive magnetic plug sensor for online condition monitoring is proposed in this article, which can achieve particle counting, debris measurement, and wear rate estimation. The sensor can detect capacitance and inductance parameters, the coil is the outer electrode to detect the dielectric change in capacitance mode, and the coil directly induces magnetic field disturbance in inductance mode. Through introducing a reference unit, Wheatstone bridge circuits are constructed to enhance the response to debris and reduce the interference of oil temperature and viscosity. A postprocessing circuit with filtering and amplifying functions is adopted to improve accuracy. The sensor output characteristics and debris position effect are studied through the experiment. The comprehensive analysis of the detection results in two modes can improve sensor adaptability and overcome the deficiency of low reliability based on a single detection method. This sensor can provide more accurate debris information for the fault diagnosis of hydraulic equipment and is of great significance for intelligent maintenance.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
A Multi-Parameter Microfluidic Particle Sensor Based on Permalloy for High Sensitivity
Technologies for particle detection in lubricating or hydraulic oil are essential in mechanical industries to avoid constant machinery failure. The existing technologies utilize offline or online methods. Some of the online methods either have weak sensitivity or can only detect one type of particle. This article presents a highly sensitive, multi-parameter sensor for detecting various particles in hydraulic oil. This design takes advantage of high magnetic permeability and shielding efficiency of permalloy, placed behind dual opposite planar coils with a straight microchannel structure to improve the sensitivity of the sensor. The design includes both an inductive mode sensor, which can detect and distinguish ferromagnetic and nonferromagnetic metallic particles, and a capacitive mode sensor, which can detect and distinguish air bubbles and water droplets. Comparative COMSOL simulation and experiment were used to investigate the effect of permalloy and the results show that the sensor with permalloy has higher sensitivity compared to the sensor without permalloy. The sensor with permalloy successfully detected 15- $\mu \text{m}$ iron particle, 55- $\mu \text{m}$ copper particle, 75- $\mu \text{m}$ water droplet, and 95- $\mu \text{m}$ air bubble. This research shows the application of permalloy in the sensitivity improvement of microfluidic sensors.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
A Multi-Parameter Microfluidic Particle Sensor Based on Permalloy for High Sensitivity
Technologies for particle detection in lubricating or hydraulic oil are essential in mechanical industries to avoid constant machinery failure. The existing technologies utilize offline or online methods. Some of the online methods either have weak sensitivity or can only detect one type of particle. This article presents a highly sensitive, multi-parameter sensor for detecting various particles in hydraulic oil. This design takes advantage of high magnetic permeability and shielding efficiency of permalloy, placed behind dual opposite planar coils with a straight microchannel structure to improve the sensitivity of the sensor. The design includes both an inductive mode sensor, which can detect and distinguish ferromagnetic and nonferromagnetic metallic particles, and a capacitive mode sensor, which can detect and distinguish air bubbles and water droplets. Comparative COMSOL simulation and experiment were used to investigate the effect of permalloy and the results show that the sensor with permalloy has higher sensitivity compared to the sensor without permalloy. The sensor with permalloy successfully detected 15- $\mu \text{m}$ iron particle, 55- $\mu \text{m}$ copper particle, 75- $\mu \text{m}$ water droplet, and 95- $\mu \text{m}$ air bubble. This research shows the application of permalloy in the sensitivity improvement of microfluidic sensors.
- Open Access
Research on High Sensitivity Oil Debris Detection Sensor Using High Magnetic Permeability Material and Coil Mutual Inductance
Metallic contaminants (solid) are generated by friction pair, causing wear of equipment by enters the lubricating system. This poses a great potential threat to the normal operation of such machines. The timely analysis and detection of debris can lead to the avoidance of mechanical failures. Abnormal wear in machinery may produce debris exceeding 10 μm. The traditional inductance detection method has low sensitivity and cannot meet the actual detection requirements. To boost the sensitivity of the inductance sensor, the mutual inductance of coils and the strong magnetic conductivity of permalloy was utilized to design a high sensitivity inductance sensor for the detection of debris in lubricating oil. This design was able to detect 10–15 μm iron particles and 65–70 μm copper particles in the oil. The experimental results illustrate that low-frequency excitation is the best for detecting ferromagnetic particles, while high-frequency excitation has the best effect for detecting non-ferromagnetic particles. This paper demonstrates the significant advantages of coil mutual inductance, and strong magnetic conductivity of permalloy in improving the detection sensitivity of oil debris sensors. This will provide technical support for wear detection in mechanical equipment and fault diagnosis.
Open AccessResearch on High Sensitivity Oil Debris Detection Sensor Using High Magnetic Permeability Material and Coil Mutual Inductance
Metallic contaminants (solid) are generated by friction pair, causing wear of equipment by enters the lubricating system. This poses a great potential threat to the normal operation of such machines. The timely analysis and detection of debris can lead to the avoidance of mechanical failures. Abnormal wear in machinery may produce debris exceeding 10 μm. The traditional inductance detection method has low sensitivity and cannot meet the actual detection requirements. To boost the sensitivity of the inductance sensor, the mutual inductance of coils and the strong magnetic conductivity of permalloy was utilized to design a high sensitivity inductance sensor for the detection of debris in lubricating oil. This design was able to detect 10–15 μm iron particles and 65–70 μm copper particles in the oil. The experimental results illustrate that low-frequency excitation is the best for detecting ferromagnetic particles, while high-frequency excitation has the best effect for detecting non-ferromagnetic particles. This paper demonstrates the significant advantages of coil mutual inductance, and strong magnetic conductivity of permalloy in improving the detection sensitivity of oil debris sensors. This will provide technical support for wear detection in mechanical equipment and fault diagnosis.