Hui Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Zhao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zhanlong Zhang
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
4 shared publications - Jiayi Xiao
School of Electrical Engineering, Chongqing University, Chongqing 400044, China
2 shared publications - Bowen Deng
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University , Chongqing 400030, China
1 shared publication - Jing Zhou
National Key Laboratory of Transmission and Transformation Equipment Technology, Chongqing University, Chongqing 400044, China
1 shared publication - Jun Deng
CSG EHV Electric Power Research Institute, Guangzhou, China
1 shared publication - Jun Deng
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University , Chongqing 400030, China
1 shared publication
Latest Publications
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Method for Measuring Thermal Flow Field Distribution in Oil-Immersed Transformer Using Dynamic Heat Transfer Coefficient
Obtaining the thermal flow field distribution in transformers is essential for ensuring reliable operation. A finite volume method is a crucial approach for obtaining the internal thermal flow field in transformers through multiphysics simulation modelling. The complexity of the transformer tank-wall structure makes it challenging to accurately calculate wall surface heat transfer coefficients using empirical formulas under varying operating conditions. This study introduces a method to calculate the dynamic convective heat transfer coefficient of the transformer tank-wall, derive the wall temperature equation, and obtain the internal thermal and flow field distribution using transformer operation data. Firstly, a finite volume method multiphysics simulation model is established for steady-state calculations of transformers, and simulated datasets of tank-wall temperatures are obtained. Subsequently, the data set undergoes PSO function optimization. Finally, the internal thermal and flow fields in the transformer are determined using dynamic heat transfer coefficients and operational data. By comparing the simulated wall temperature distribution with experimental measurements, the feasibility and accuracy of the proposed method have been confirmed. The finite volume multiphysics field calculation method for the internal thermal flow field of transformers based on dynamic heat transfer coefficients can disregard the complexity of the transformer tank-wall structure and consider the varying operating conditions, compared to empirical formulas (5.238K), it has a smaller maximum error (1.373K), demonstrating clear practical value.
- 7 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Method for Measuring Thermal Flow Field Distribution in Oil-Immersed Transformer Using Dynamic Heat Transfer Coefficient
Obtaining the thermal flow field distribution in transformers is essential for ensuring reliable operation. A finite volume method is a crucial approach for obtaining the internal thermal flow field in transformers through multiphysics simulation modelling. The complexity of the transformer tank-wall structure makes it challenging to accurately calculate wall surface heat transfer coefficients using empirical formulas under varying operating conditions. This study introduces a method to calculate the dynamic convective heat transfer coefficient of the transformer tank-wall, derive the wall temperature equation, and obtain the internal thermal and flow field distribution using transformer operation data. Firstly, a finite volume method multiphysics simulation model is established for steady-state calculations of transformers, and simulated datasets of tank-wall temperatures are obtained. Subsequently, the data set undergoes PSO function optimization. Finally, the internal thermal and flow fields in the transformer are determined using dynamic heat transfer coefficients and operational data. By comparing the simulated wall temperature distribution with experimental measurements, the feasibility and accuracy of the proposed method have been confirmed. The finite volume multiphysics field calculation method for the internal thermal flow field of transformers based on dynamic heat transfer coefficients can disregard the complexity of the transformer tank-wall structure and consider the varying operating conditions, compared to empirical formulas (5.238K), it has a smaller maximum error (1.373K), demonstrating clear practical value.
- 20 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
A Dynamic Monitoring Method of Temperature Distribution for Cable Joints Based on Thermal Knowledge and Conditional Generative Adversarial Network
The dynamic monitoring of the temperature distribution of power equipment is crucial for safe operation. The monitoring method based on digital twin technology has received extensive attention due to its ability to provide more timely and more comprehensive analysis. However, the existing methods only use physics-driven or data-driven methods separately, which cannot simultaneously meet application requirements such as low cost, high efficiency, effective results and sufficient training data. Therefore, a new dynamic monitoring method of temperature distribution based on thermal knowledge and conditional generative adversarial network (CGAN) are proposed in this paper, with a high voltage cable joint taken as an example. First, the steady-state numerical model of the temperature field is established. The thermal image set under different operation conditions is obtained through simulation. The data-driven method based on the CGAN model is applied to learn the data laws between operation conditions and thermal images, and constructs a mapping relationship between them. Then, the physics-driven method based on thermal knowledge is used to reduce feature dimensions and extract input features from real-time measurement data. These input features drive the generator of the CGAN model to generate the thermal images dynamically. By comparing the generation results with numerical and experimental results, the proposed method can achieve the dynamic monitoring of temperature for cable joints, which has comprehensive advantages with regards to the time efficiency, computational cost, monitoring accuracy and generalization ability. It provides new insights into the digital twin technology of power equipment.
- 20 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
A Dynamic Monitoring Method of Temperature Distribution for Cable Joints Based on Thermal Knowledge and Conditional Generative Adversarial Network
The dynamic monitoring of the temperature distribution of power equipment is crucial for safe operation. The monitoring method based on digital twin technology has received extensive attention due to its ability to provide more timely and more comprehensive analysis. However, the existing methods only use physics-driven or data-driven methods separately, which cannot simultaneously meet application requirements such as low cost, high efficiency, effective results and sufficient training data. Therefore, a new dynamic monitoring method of temperature distribution based on thermal knowledge and conditional generative adversarial network (CGAN) are proposed in this paper, with a high voltage cable joint taken as an example. First, the steady-state numerical model of the temperature field is established. The thermal image set under different operation conditions is obtained through simulation. The data-driven method based on the CGAN model is applied to learn the data laws between operation conditions and thermal images, and constructs a mapping relationship between them. Then, the physics-driven method based on thermal knowledge is used to reduce feature dimensions and extract input features from real-time measurement data. These input features drive the generator of the CGAN model to generate the thermal images dynamically. By comparing the generation results with numerical and experimental results, the proposed method can achieve the dynamic monitoring of temperature for cable joints, which has comprehensive advantages with regards to the time efficiency, computational cost, monitoring accuracy and generalization ability. It provides new insights into the digital twin technology of power equipment.
- 1 December 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (12) , 123902
Microscopic analysis of Trichel's pulse characteristics and the effect of air pressure and temperature
The negative direct current corona discharge experiment under the needle-plate electrode is conducted, and the typical Trichel pulse waveform is obtained. Furthermore, to analyze the microscopic process of corona discharge, a plasma-fluid discharge simulation model, including air chemical reactions, is established, and a Trichel pulse waveform is obtained, which is consistent with the experimentally obtained waveform. Thus, the chemical reaction that plays a dominant role in the generation and disappearance of charged particles as well as the spatiotemporal distribution and quantitative variation of charged particles during the discharge process are clarified. On this basis, the variation of the microscopic and macroscopic parameters in the discharge process under different air pressure and temperature conditions is studied. The results show that microscopic parameters, such as charge density and electric field intensity, are negatively associated with air pressure and positively associated with temperature, while macroscopic parameters, such as Trichel pulse average current, average peak current, and discharge frequency, are positively associated with the microscopic parameters.
- 1 December 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (12) , 123902
Microscopic analysis of Trichel's pulse characteristics and the effect of air pressure and temperature
The negative direct current corona discharge experiment under the needle-plate electrode is conducted, and the typical Trichel pulse waveform is obtained. Furthermore, to analyze the microscopic process of corona discharge, a plasma-fluid discharge simulation model, including air chemical reactions, is established, and a Trichel pulse waveform is obtained, which is consistent with the experimentally obtained waveform. Thus, the chemical reaction that plays a dominant role in the generation and disappearance of charged particles as well as the spatiotemporal distribution and quantitative variation of charged particles during the discharge process are clarified. On this basis, the variation of the microscopic and macroscopic parameters in the discharge process under different air pressure and temperature conditions is studied. The results show that microscopic parameters, such as charge density and electric field intensity, are negatively associated with air pressure and positively associated with temperature, while macroscopic parameters, such as Trichel pulse average current, average peak current, and discharge frequency, are positively associated with the microscopic parameters.
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 033509
Numerical analysis of temperature characterization of air gap discharge in solid insulation under power frequency voltage
Air gap defects in solid insulation of power equipment can cause partial discharge. Temperature, as an important characterization of partial discharge, can be used as a criterion for the deterioration degree of air gap defects to some extent. In this paper, the temperature characterization of air gap discharge is studied. A plasma-kinetics-based dielectric barrier discharge model is constructed. The calculation method of air gap discharge heat source under power frequency voltage is presented. Moreover, the influence of voltage amplitude and gap thickness on temperature is studied. Obtained results indicate that under the power frequency voltage, Joule (Ohmic) heat contributes 90% to the heat source, and O4+ and O2+ and electron e are the main contributors to Joule (Ohmic) heat. O4+ is also the dominant ion in the mixed gas. As the discharge progressed, O4+ almost all clustered near the instantaneous cathode. The O2+ density generally depends on the electron density, but compared with the electron, the spatial distribution of O2+ density is slightly shifted to the instantaneous cathode. The discharge heat source is positively correlated with the air gap thickness and the voltage amplitude. With the increase in air gap thickness, the rising rate of heat sources will also increase. However, when the voltage is 10 kV, the heat source increases first and then decreases with the increase in the air gap thickness. The discharge does not occur when the air gap thickness reaches above 4 mm. This study provides theoretical support for identifying the deterioration degree of air gap defects from the view of temperature.
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 033509
Numerical analysis of temperature characterization of air gap discharge in solid insulation under power frequency voltage
Air gap defects in solid insulation of power equipment can cause partial discharge. Temperature, as an important characterization of partial discharge, can be used as a criterion for the deterioration degree of air gap defects to some extent. In this paper, the temperature characterization of air gap discharge is studied. A plasma-kinetics-based dielectric barrier discharge model is constructed. The calculation method of air gap discharge heat source under power frequency voltage is presented. Moreover, the influence of voltage amplitude and gap thickness on temperature is studied. Obtained results indicate that under the power frequency voltage, Joule (Ohmic) heat contributes 90% to the heat source, and O4+ and O2+ and electron e are the main contributors to Joule (Ohmic) heat. O4+ is also the dominant ion in the mixed gas. As the discharge progressed, O4+ almost all clustered near the instantaneous cathode. The O2+ density generally depends on the electron density, but compared with the electron, the spatial distribution of O2+ density is slightly shifted to the instantaneous cathode. The discharge heat source is positively correlated with the air gap thickness and the voltage amplitude. With the increase in air gap thickness, the rising rate of heat sources will also increase. However, when the voltage is 10 kV, the heat source increases first and then decreases with the increase in the air gap thickness. The discharge does not occur when the air gap thickness reaches above 4 mm. This study provides theoretical support for identifying the deterioration degree of air gap defects from the view of temperature.