Quan Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Quan Han has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Xiaohui Yang
School of Chemical Engineering, Xi’an University, Xi’an 710065, China
2 shared publications - Yanyan Huo
School of Chemical Engineering, Xi’an University, Xi’an 710065, China
2 shared publications - Dan Li
School of Chemical Engineering, Xi’an University, Xi’an 710065, China
1 shared publication X. H. Yang
School of Chemical Engineering, Xi’an University, Xi’an, Shaan Xi, China
1 shared publicationXiaohui Yang
School of Chemical Engineering, Xi’an University, Xi’an, China
1 shared publicationY. H. Zhai
School of Chemical Engineering, Xi’an University, Xi’an, Shaan Xi, China
1 shared publication
Latest Publications
- Open Access
Determination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry
A new method has been established for determining trace amounts of platinum in water using ion liquid (IL)-dispersive liquid–liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The method is based on the use of a self-prepared reagent, 5-(5-cyano-2-pyridineazo)-2,4-diaminotoluene (5-CN-PADAT), as a chelating agent, which reacts with Pt(IV) to form a hydrophobic chelate. The extraction solvent is 1-octyl-3-methylimidazolium hexafluorophosphate ([C8mim][PF6]), and ethyl acetate is used as the dispersive solvent. After the extraction is completed, the extraction phase formed by [C8mim][PF6] and ethyl acetate has a relatively low viscosity and can be directly used for the determination of GFAAS. A single-factor rotational method was employed to optimize conditions affecting DLLME extraction efficiency. The interactions among the factors affecting DLLME were analyzed using response surface optimization (RSM). Under optimal conditions, platinum concentrations exhibited good linearity within the range of 40–280 ng/mL, with a detection limit of 0.3 ng/mL. AGREEprep was used to discuss the ecological friendliness of the method, demonstrating its low cost, ease of operation, simple equipment requirements, and environmental friendliness. When applied to determining trace amounts of platinum in water samples, the results were satisfactory.
Open AccessDetermination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry
A new method has been established for determining trace amounts of platinum in water using ion liquid (IL)-dispersive liquid–liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The method is based on the use of a self-prepared reagent, 5-(5-cyano-2-pyridineazo)-2,4-diaminotoluene (5-CN-PADAT), as a chelating agent, which reacts with Pt(IV) to form a hydrophobic chelate. The extraction solvent is 1-octyl-3-methylimidazolium hexafluorophosphate ([C8mim][PF6]), and ethyl acetate is used as the dispersive solvent. After the extraction is completed, the extraction phase formed by [C8mim][PF6] and ethyl acetate has a relatively low viscosity and can be directly used for the determination of GFAAS. A single-factor rotational method was employed to optimize conditions affecting DLLME extraction efficiency. The interactions among the factors affecting DLLME were analyzed using response surface optimization (RSM). Under optimal conditions, platinum concentrations exhibited good linearity within the range of 40–280 ng/mL, with a detection limit of 0.3 ng/mL. AGREEprep was used to discuss the ecological friendliness of the method, demonstrating its low cost, ease of operation, simple equipment requirements, and environmental friendliness. When applied to determining trace amounts of platinum in water samples, the results were satisfactory.
- 26 September 2024
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 46 (5) , 480-490
Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
A new method for the determination of ultra-trace cobalt by ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and graphite furnace atomic ab
- 26 September 2024
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 46 (5) , 480-490
Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
A new method for the determination of ultra-trace cobalt by ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and graphite furnace atomic ab
- Open Access
Determination of Ultra-Trace Cobalt in Water Samples Using Dispersive Liquid-Liquid Microextraction Followed by Graphite Furnace Atomic Absorption Spectrometry
A novel method for the determination of ultra-trace cobalt by dispersive liquid–liquid microextraction (DLLME) coupled with graphite furnace atomic absorption spectrometry has been developed. It is based on the color reaction of Co2+ with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in a Britton–Robinson buffer solution at pH 6.0 to form stable hydrophobic chelates, which were separated and enriched by DLLME with 1,2-dichloroethane (CH2ClCH2Cl) as extraction and acetonitrile (CH3CN) as a dispersive solvent. The sedimented phase containing the chelates is then determined with GFAAS. Parameters that affect extraction efficiency, such as types and volumes of extraction and disperser solvents, pH of sample solution, extraction time, concentration of the chelating agent 5-Br-PADMA, and salt effect, were investigated. Under optimal conditions, the calibration graph was linear over the range 0.05–1.0 ng/mL, with a correlation coefficient of 0.9922 and a detection limit of 0.03 ng/mL. Preconcentration factor (PF) is calculated as the ratio of the aqueous solution volume (5 mL) to that of the organic phase volume (40 μL), and enrichment factor (EF) is calculated as the ratio of the slopes of the calibration graphs obtained with and without DLLME for 5.0 mL of sample solution, which were 120 and 112.5, respectively. The extraction efficiency, calculated by EF/PF·100, was 93.8%. The relative standard deviation (RSD) at the 0.5 ng/mL Co2+ level was 3.8% (n = 6). The method has been applied to the determination of trace cobalt in water samples with satisfactory results.
Open AccessDetermination of Ultra-Trace Cobalt in Water Samples Using Dispersive Liquid-Liquid Microextraction Followed by Graphite Furnace Atomic Absorption Spectrometry
A novel method for the determination of ultra-trace cobalt by dispersive liquid–liquid microextraction (DLLME) coupled with graphite furnace atomic absorption spectrometry has been developed. It is based on the color reaction of Co2+ with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in a Britton–Robinson buffer solution at pH 6.0 to form stable hydrophobic chelates, which were separated and enriched by DLLME with 1,2-dichloroethane (CH2ClCH2Cl) as extraction and acetonitrile (CH3CN) as a dispersive solvent. The sedimented phase containing the chelates is then determined with GFAAS. Parameters that affect extraction efficiency, such as types and volumes of extraction and disperser solvents, pH of sample solution, extraction time, concentration of the chelating agent 5-Br-PADMA, and salt effect, were investigated. Under optimal conditions, the calibration graph was linear over the range 0.05–1.0 ng/mL, with a correlation coefficient of 0.9922 and a detection limit of 0.03 ng/mL. Preconcentration factor (PF) is calculated as the ratio of the aqueous solution volume (5 mL) to that of the organic phase volume (40 μL), and enrichment factor (EF) is calculated as the ratio of the slopes of the calibration graphs obtained with and without DLLME for 5.0 mL of sample solution, which were 120 and 112.5, respectively. The extraction efficiency, calculated by EF/PF·100, was 93.8%. The relative standard deviation (RSD) at the 0.5 ng/mL Co2+ level was 3.8% (n = 6). The method has been applied to the determination of trace cobalt in water samples with satisfactory results.
- 1 February 2022
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 44 (1) , 31-39
Cloud Point Extraction Coupled with Laser Thermal Lens Spectrometry for Determination of Trace Palladium in Environmental Water Samples
A highly sensitive, simple and safe method has been developed for the determination of trace palladium by cloud point extraction (CPE) combined with therma
- 1 February 2022
- Published by Allerton Press in Journal of Water Chemistry and Technology
- Vol. 44 (1) , 31-39
Cloud Point Extraction Coupled with Laser Thermal Lens Spectrometry for Determination of Trace Palladium in Environmental Water Samples
A highly sensitive, simple and safe method has been developed for the determination of trace palladium by cloud point extraction (CPE) combined with therma