Qun Wang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qun Wang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoyu Jin
Ningbo Sub-academy of the National Weapons Science Research Academy 315103 Ningbo China
3 shared publications - Jinjun Tang
Ningbo Sub-academy of the National Weapons Science Research Academy 315103 Ningbo China
2 shared publications - Yu-Lei Li
National Weapons Science Research Academy 315103 Ningbo China
2 shared publications - Haiyong Ao
School of Materials Science and Engineering, East China Jiaotong University, Nanchang, 330013, China
1 shared publication - Jin-Jun Tang
National Weapons Science Research Academy 315103 Ningbo China
1 shared publication - Lijun Zhang
The Ningbo Branch of Ordnance Science Institute of China, Ningbo, Zhejiang, China
1 shared publication
Latest Publications
- Open Access
Surface Modification of Titanium by Femtosecond Laser in Reducing Bacterial Colonization
In the past few decades, titanium and its alloys have been widely used in the orthopaedic field. However, because titanium is bioinert and lacks antibacterial properties, infection may happen when bacteria attach to implant surfaces and form biofilms. It has been studied that some naturally existing micron-scale topographies can reduce bacterial attachment such as cicada wings and gecko skins. The aim of this in vitro study was to find an implant with good biocompatibility and antimicrobial properties by the modification of micron-scale topographies. In this paper, a femtosecond laser was used to provide microtopography coatings on Ti substrates. The surface morphology of Ti substrates was observed by scanning electron microscopy (SEM). XPS was used to fulfil the chemical compositional analysis. The surface wettability was measured by contact angle measurement system. The effect of microtopography coatings with different surface microstructures on bacterial activities and bone marrow mesenchymal stem cells (BMSC) functions was investigated. The results of in vitro study revealed that microtopography coatings restrain the adhesion of Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis), which are common pathogens of orthopaedic implant infections. In addition, microtopography coatings stimulated BMSC adhesion and proliferation. Our studies suggest that a microtopography-coated sample modified by femtosecond laser showed promising antibacterial properties and favourable biocompatibility. The femtosecond laser technique provides an accurate and valid way to produce microtopography coatings with outstanding biocompatibility and antimicrobial properties, and could be widely used to modify the surface of orthopaedic metal implants with great potential.
Open AccessSurface Modification of Titanium by Femtosecond Laser in Reducing Bacterial Colonization
In the past few decades, titanium and its alloys have been widely used in the orthopaedic field. However, because titanium is bioinert and lacks antibacterial properties, infection may happen when bacteria attach to implant surfaces and form biofilms. It has been studied that some naturally existing micron-scale topographies can reduce bacterial attachment such as cicada wings and gecko skins. The aim of this in vitro study was to find an implant with good biocompatibility and antimicrobial properties by the modification of micron-scale topographies. In this paper, a femtosecond laser was used to provide microtopography coatings on Ti substrates. The surface morphology of Ti substrates was observed by scanning electron microscopy (SEM). XPS was used to fulfil the chemical compositional analysis. The surface wettability was measured by contact angle measurement system. The effect of microtopography coatings with different surface microstructures on bacterial activities and bone marrow mesenchymal stem cells (BMSC) functions was investigated. The results of in vitro study revealed that microtopography coatings restrain the adhesion of Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis), which are common pathogens of orthopaedic implant infections. In addition, microtopography coatings stimulated BMSC adhesion and proliferation. Our studies suggest that a microtopography-coated sample modified by femtosecond laser showed promising antibacterial properties and favourable biocompatibility. The femtosecond laser technique provides an accurate and valid way to produce microtopography coatings with outstanding biocompatibility and antimicrobial properties, and could be widely used to modify the surface of orthopaedic metal implants with great potential.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1827 (1) , 012114
Design and mechanical failure analysis of Ti6Al4V alloy thin-walled parts by selective laser melting(SLM) manufacture
There is a growing interest in using additive manufacturing to produce smart structures, which have the capability to respond to thermal and mechanical stimulation. In this report, Selective Laser Melting (SLM) is used to build a thin-walled titanium alloy structure. The part creating a ultra lightweight is 2.15g, while its strenght achieve at 132.4MPa. The stages of compression process was analyzed in detail, meanwhile the deformation and failure mechanism of the thin-walled part was described.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1827 (1) , 012114
Open AccessDesign and mechanical failure analysis of Ti6Al4V alloy thin-walled parts by selective laser melting(SLM) manufacture
There is a growing interest in using additive manufacturing to produce smart structures, which have the capability to respond to thermal and mechanical stimulation. In this report, Selective Laser Melting (SLM) is used to build a thin-walled titanium alloy structure. The part creating a ultra lightweight is 2.15g, while its strenght achieve at 132.4MPa. The stages of compression process was analyzed in detail, meanwhile the deformation and failure mechanism of the thin-walled part was described.
- Open Access
- 1 January 2017
- Published by Atlantis Press SARL
Study on the Key Technology of Micro-arc Oxidation of TA2 Titanium for Medical Use
- 1 January 2017
- Published by Atlantis Press SARL
Open AccessStudy on the Key Technology of Micro-arc Oxidation of TA2 Titanium for Medical Use
- Open Access
- 1 January 2016
- Published by Atlantis Press SARL
Study on the Microstructure Properties of Titanium Metal Crown Base Laser Rapid Forming
- 1 January 2016
- Published by Atlantis Press SARL
Open AccessStudy on the Microstructure Properties of Titanium Metal Crown Base Laser Rapid Forming
- Open Access
- 1 January 2016
- Published by Atlantis Press SARL
Study on the Key Technology of 3D Printing Pure Titanium Metal Porcelain Teeth
- 1 January 2016
- Published by Atlantis Press SARL
Open AccessStudy on the Key Technology of 3D Printing Pure Titanium Metal Porcelain Teeth