Karine E. Borne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Karine E. Borne has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Caroline Gentric
Nantes Université
1 shared publication- Claire Gerente
Laboratoire de Génie des Procédés Environnement Agro-Alimentaire (UMR CNRS 6144), Institut Mines Télécom Atlantique, 44300 Nantes, France
1 shared publication - Félicie Theron
IMT Atlantique
1 shared publication Jan Ruppelt
Institute for Environmental Engineering, RWTH Aachen University, D-52056, Aachen, Germany
1 shared publicationKatharina Tondera
INRAE, REVERSAL, F-69625, Villeurbanne, France
1 shared publication- Maxime Ghods
Nantes Université
1 shared publication
Latest Publications
- 1 February 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Sustainable Water in the Built Environment
- Vol. 13 (1) , 04026019
Hydrodynamics Induced by Floating Treatment Wetlands: Impact of the Flow Velocity and Root Network on Flow Structure and Suspended Solids Removal
Floating treatment wetlands (FTWs) have been increasingly studied and applied over the last 15 years, yet the conditions for their effective implementation are still not fully understood. To refine current understanding and identify conditions that maximize particulate pollutant removal, a flume experiment with a real FTW was conducted to investigate how the mean flow velocity ( U 1 = 0.018 m · s − 1 ; U 2 = 0.083 m · s − 1 ; and U 3 = 0.171 m · s − 1 ) and root-network characteristics (i.e., R = ratio of the water column occupied by the FTW over the total pond water depth) influence the flow structure and associated suspended solids (SS) retention within FTWs. Flow acceleration (up to twice the mean flow velocity) and deceleration occurred underneath and downstream, respectively, of the FTW having a rooting depth ratio R of 0.56 ( FTW 0.56 ). A substantial fraction of the flow was diverted toward the flume bottom—particularly under U 1 —reducing root–flow contact and particle entrapment. Under higher velocities, the flow could penetrate deeper into the root network, increasing opportunities for particles’ entrapment and increased treatment benefits. The results indicated that FTW 0.56 could enhance pond treatment efficiency by up to ∼ 35 % , with greater benefits at higher velocities. This is partly due to reduced performances of conventional ponds to settle particles under these higher flow velocities ( U 2 and U 3 ). Increasing the rooting depth ratio (e.g., 0.87) would further improve efficiency, especially under low flow (up to three times higher removal efficiency), where FTW 0.56 offered limited additional benefit because of greater short-circuiting around the root network. Overall, the results of the present study suggest that careful consideration should be given to the flow the FTWs are subject to, the original pond design and its performance toward natural settling, to evaluate whether inclusion of FTWs would provide sufficient additional treatment benefits.
- 1 February 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Sustainable Water in the Built Environment
- Vol. 13 (1) , 04026019
Hydrodynamics Induced by Floating Treatment Wetlands: Impact of the Flow Velocity and Root Network on Flow Structure and Suspended Solids Removal
Floating treatment wetlands (FTWs) have been increasingly studied and applied over the last 15 years, yet the conditions for their effective implementation are still not fully understood. To refine current understanding and identify conditions that maximize particulate pollutant removal, a flume experiment with a real FTW was conducted to investigate how the mean flow velocity ( U 1 = 0.018 m · s − 1 ; U 2 = 0.083 m · s − 1 ; and U 3 = 0.171 m · s − 1 ) and root-network characteristics (i.e., R = ratio of the water column occupied by the FTW over the total pond water depth) influence the flow structure and associated suspended solids (SS) retention within FTWs. Flow acceleration (up to twice the mean flow velocity) and deceleration occurred underneath and downstream, respectively, of the FTW having a rooting depth ratio R of 0.56 ( FTW 0.56 ). A substantial fraction of the flow was diverted toward the flume bottom—particularly under U 1 —reducing root–flow contact and particle entrapment. Under higher velocities, the flow could penetrate deeper into the root network, increasing opportunities for particles’ entrapment and increased treatment benefits. The results indicated that FTW 0.56 could enhance pond treatment efficiency by up to ∼ 35 % , with greater benefits at higher velocities. This is partly due to reduced performances of conventional ponds to settle particles under these higher flow velocities ( U 2 and U 3 ). Increasing the rooting depth ratio (e.g., 0.87) would further improve efficiency, especially under low flow (up to three times higher removal efficiency), where FTW 0.56 offered limited additional benefit because of greater short-circuiting around the root network. Overall, the results of the present study suggest that careful consideration should be given to the flow the FTWs are subject to, the original pond design and its performance toward natural settling, to evaluate whether inclusion of FTWs would provide sufficient additional treatment benefits.
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Recycled Cellular Concrete to Upgrade Phosphorous Removal in Floating Treatment Wetland: A Pilot Experiment for Meat-Processing Factory's Wastewater
Floating Treatment Wetlands (FTW) are a promising solution for the treatment of wastewater, yet they exhibit a wide range of Total Phosphorous (TP) removal performances, raising uncertainty about their reliability. This study investigates the potential of enhanced FTW equipped with recycled cellular concrete (CC) to improve the phosphorous (P) treatment of agri-food wastewater. A side-by-side evaluation of different size FTWs (representing 24%, 48%, and 72% of pilot lagoons' surface with 5, 10 and 15 kg CC, respectively) and a control (pilot lagoon without FTW) was performed. The pilot lagoon with a 72% coverage ratio exhibited the highest TP mass removal, averaging 29 ± 9 % and resulting in a 16% median increase compared to the control lagoon. The 24% and 48% coverage FTW promoted more consistent and less variable TP treatment efficiency than the control lagoon, which achieved P removal only during algal blooms. Phosphorous was mostly sorbed onto CC within FTW (min-max: 79 – 94% of TP removed). Plants had little contribution to overall phosphorous removal and were responsible for 4 – 6 % of TP removed depending on plant density. Sedimentation and algal assimilation and were responsible for 14% of TP removed in the densest FTW, and were the main TP removal driving force in the control lagoon. From a circular economy perspective, up to 31 g P/kg CC were sorbed on CC, of which 89% (weakly and calcium-bound P) could be available to plant assimilation. Further investigation over CC could provide insight into the best valorization route.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessRecycled Cellular Concrete to Upgrade Phosphorous Removal in Floating Treatment Wetland: A Pilot Experiment for Meat-Processing Factory's Wastewater
Floating Treatment Wetlands (FTW) are a promising solution for the treatment of wastewater, yet they exhibit a wide range of Total Phosphorous (TP) removal performances, raising uncertainty about their reliability. This study investigates the potential of enhanced FTW equipped with recycled cellular concrete (CC) to improve the phosphorous (P) treatment of agri-food wastewater. A side-by-side evaluation of different size FTWs (representing 24%, 48%, and 72% of pilot lagoons' surface with 5, 10 and 15 kg CC, respectively) and a control (pilot lagoon without FTW) was performed. The pilot lagoon with a 72% coverage ratio exhibited the highest TP mass removal, averaging 29 ± 9 % and resulting in a 16% median increase compared to the control lagoon. The 24% and 48% coverage FTW promoted more consistent and less variable TP treatment efficiency than the control lagoon, which achieved P removal only during algal blooms. Phosphorous was mostly sorbed onto CC within FTW (min-max: 79 – 94% of TP removed). Plants had little contribution to overall phosphorous removal and were responsible for 4 – 6 % of TP removed depending on plant density. Sedimentation and algal assimilation and were responsible for 14% of TP removed in the densest FTW, and were the main TP removal driving force in the control lagoon. From a circular economy perspective, up to 31 g P/kg CC were sorbed on CC, of which 89% (weakly and calcium-bound P) could be available to plant assimilation. Further investigation over CC could provide insight into the best valorization route.
- 16 March 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 312, 114909
Optimizing floating treatment wetland and retention pond design through random forest: A meta-analysis of influential variables
- 16 March 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 312, 114909
Optimizing floating treatment wetland and retention pond design through random forest: A meta-analysis of influential variables