JVJulia E. Vallier

Julia E. Vallier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julia E. Vallier has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A robust and user-agnostic step-emulsion platform for scalable microgel fabrication

    by Durante Pioche-Lee, Shiyu Yang, Xiaoqian Wang, Yoke Qi Ho, Wahidur Rahman, Armen C. Vartanian, Despina I. Pavlidis, Irene W. Zhang, Julia E. Vallier, Emily McCorkle, et al.

    Over the past decade, the integration of microgel-based granular hydrogels in biomedical technologies has experienced substantial growth due to the numerous benefits microgels offer. However, the inability to easily adopt uniform microgel fabrication workflows at scale constitutes a major bottleneck, or in some cases, a barrier-to-entry that stunts further growth of the field. The gold-standard technique for emulsion-based microgel production is through microfluidic droplet-generating devices that produce liquid gel precursor droplets that gel post-production. However, traditional microfluidic workflows often require multiple independent flows and controlled pressure sources, along with a steep learning curve in using microfluidics to achieve uniform droplet sizes reproducibly and repeatedly. This difficulty in adopting microgel fabrication is further compounded by low throughput and the extensive flow rate calibration required when switching to new formulations (e.g., material type, droplet size). In this work, we present a step-emulsion system that bridges the gap by providing a robust and simple setup. We experimentally characterize and evaluate how flow and outlet channel dimension contribute to the generation of uniform droplet populations at specific sizes. With our large dataset consisting of various outlet channel dimensions, we evaluated outlet channel geometrical impacts (height, width, cross-sectional area, aspect-ratio, etc.) on gel precursor droplet size and generation throughput. We demonstrate robust, highly compatible, and repeatably uniform droplet generation from various gel precursor polymer backbones, users with varying microfluidics experience, and a wide viscosity range, including alginate solutions with 650 times the viscosity of water. Furthermore, we confirmed consistent gel precursor droplet generation outcomes driven by a constant flow source (syringe pump) and by direct manual injection as a simple and highly adoptable option for the generation of gel precursor droplets. This platform is ideal for researchers seeking rapid and easy microgel fabrication, regardless of microfluidics experience.

  • Open Access

    Microfluidics-Enabled Simultaneous Imaging of Neural Activity and Behavior in Chemically Stimulated, Head-Fixed C. elegans

    by Hyun Jee Lee, Julia Vallier, Hang Lu

    Understanding how the brain processes sensory information and produces appropriate behavior is a fundamental question in neuroscience. In this study, we developed a novel microfluidic device that allows for simultaneous observation of neural activity and behavior in Caenorhabditis elegans ( C. elegans ) during chemosensory stimulation. Traditional methods often involve trade-offs between high-resolution neuronal imaging, behavioral recording, and the ability to apply chemical stimulation. Our innovative design overcomes these limitations by immobilizing the worm’s head, stabilizing neuronal imaging, while allowing the posterior portion of the body to move freely, enabling the study of naturalistic behaviors during chemical stimulation. We applied this device to investigate how C. elegans responds to both attractive and aversive chemical cues. By correlating neural activity with observed behavior, we identified neurons and whole-brain dynamics associated with specific movements. Our results demonstrate that providing the worm with greater freedom of movement results in more naturalistic neuronal and behavioral responses to stimuli, compared to fully immobilized setups. This new tool offers a powerful approach for studying how sensory information is processed in the C. elegans nervous system to generate behavior, with potential applications in other model organisms. Its versatility and ease of operation make this device broadly applicable for studying how neural circuits drive behavior and decision-making in complex environments.


  • Open Access

    Microfluidic localized hydrogel polymerization enables simultaneous recording of neural activity and behavior in C. elegans

    by Hyun Jee Lee, Julia Vallier, Hang Lu

    A new microfluidic tool, using hydrogel photopolymerization, was developed to selectively immobilize the head region of C. elegans for simultaneous recording of its neuronal activity and tail movement.