Brandon T. Gaston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brandon T. Gaston has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Tiffany R. Bellomo
Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA
3 shared publications Aderike Anjorin
2 shared publicationsAnahita Dua
2 shared publications- Anahita Dua
Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA
2 shared publications - Bianca Mulaney-Topkar
Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA
2 shared publications Falen Demsas
2 shared publications
Latest Publications
- 12 October 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 38 (1)
In Vitro Development and Evaluation of an Endovascular Islet Cell Stent for Type 1 Diabetes Mellitus
- 12 October 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 38 (1)
In Vitro Development and Evaluation of an Endovascular Islet Cell Stent for Type 1 Diabetes Mellitus
- 14 September 2026
- Published by Wolters Kluwer Health in Annals of Surgery
Patterns of Index Endovascular Compared With Surgical Revascularization for Femoropopliteal Disease in Patients With Claudication Using Medicare-linked Data
Objective: To compare outcomes of endovascular versus open infrainguinal bypass in patients with claudication. Summary of Background Data: PAD research has focused largely on CLTI, yet 20% of patients present with claudication and may not improve with medical therapy alone. Durability of endovascular intervention remains uncertain. Methods: Patients undergoing bypass for femoropopliteal disease were propensity matched to endovascular procedures using demographics, cardiovascular comorbidities, and center volume quartiles. Primary outcomes (CLTI, MALE) were ascertained via VISION-Medicare linkage. Secondary outcomes included reintervention and mortality. Kaplan-Meier and Cox models quantified associations between intervention and outcome. Sensitivity analysis used inverse probability weighting and Fine-Gray models. Results: Seven hundred twenty open bypass procedures were matched to 3259 endovascular procedures (median follow-up 2.8 y, IQR 1.6–4.4). Median age was 72 versus 70 years (open vs. endovascular, P P P P =0.015), but not at 3 (49.5% vs. 49.1%, P =0.172), or 5 years (57.0% vs. 59.1%, P =0.149). CLTI progression, reintervention rates, and mortality were similar at 5 years. Endovascular intervention was not associated with MALE (HR 1.13, 95% CI: 0.97–1.32), CLTI progression (HR 0.90, 95% CI: 0.72–1.13), reintervention (HR 1.13, 95% CI: 0.97–1.32), or mortality (HR 0.86, 95% CI: 0.66–1.12). Conclusion: Open bypass and endovascular intervention demonstrated similar long-term MALE and progression to CLTI through 5 years, suggesting endovascular intervention may offer comparable outcomes in appropriately selected patients with claudication.
- 14 September 2026
- Published by Wolters Kluwer Health in Annals of Surgery
Patterns of Index Endovascular Compared With Surgical Revascularization for Femoropopliteal Disease in Patients With Claudication Using Medicare-linked Data
Objective: To compare outcomes of endovascular versus open infrainguinal bypass in patients with claudication. Summary of Background Data: PAD research has focused largely on CLTI, yet 20% of patients present with claudication and may not improve with medical therapy alone. Durability of endovascular intervention remains uncertain. Methods: Patients undergoing bypass for femoropopliteal disease were propensity matched to endovascular procedures using demographics, cardiovascular comorbidities, and center volume quartiles. Primary outcomes (CLTI, MALE) were ascertained via VISION-Medicare linkage. Secondary outcomes included reintervention and mortality. Kaplan-Meier and Cox models quantified associations between intervention and outcome. Sensitivity analysis used inverse probability weighting and Fine-Gray models. Results: Seven hundred twenty open bypass procedures were matched to 3259 endovascular procedures (median follow-up 2.8 y, IQR 1.6–4.4). Median age was 72 versus 70 years (open vs. endovascular, P P P P =0.015), but not at 3 (49.5% vs. 49.1%, P =0.172), or 5 years (57.0% vs. 59.1%, P =0.149). CLTI progression, reintervention rates, and mortality were similar at 5 years. Endovascular intervention was not associated with MALE (HR 1.13, 95% CI: 0.97–1.32), CLTI progression (HR 0.90, 95% CI: 0.72–1.13), reintervention (HR 1.13, 95% CI: 0.97–1.32), or mortality (HR 0.86, 95% CI: 0.66–1.12). Conclusion: Open bypass and endovascular intervention demonstrated similar long-term MALE and progression to CLTI through 5 years, suggesting endovascular intervention may offer comparable outcomes in appropriately selected patients with claudication.
- Open Access
- 22 June 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Comparative analysis of frailty indices in predicting outcomes after aortic aneurysm repair
- 22 June 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Open AccessComparative analysis of frailty indices in predicting outcomes after aortic aneurysm repair
- 22 September 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 83 (2) , 539-553
Direct comparison of frailty scores and their association with postoperative outcomes in patients undergoing lower extremity revascularization
- 22 September 2025
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 83 (2) , 539-553
Direct comparison of frailty scores and their association with postoperative outcomes in patients undergoing lower extremity revascularization
- 1 July 2023
- Published by Hogrefe Publishing Group in Vasa
- Vol. 52 (4) , 249-256
Wall shear rate and energy loss coefficient measures using conventional Doppler ultrasound do not predict carotid plaque progression
Summary: Background: The rate of carotid plaque progression is believed to be related to blood flow hemodynamics and shear stress. Our objective was to determine if wall shear rate (WSR) and the energy loss coefficient (ELC) measured by Doppler ultrasound could predict atherosclerotic carotid disease progression. Patients and methods: Patients at a large tertiary center with an initial ultrasound between 2016 and 2018 with a significant carotid plaque were included if they had at least one 6 months follow-up comparative study. Stenosis progression was assessed according to the NASCET (The North American Symptomatic Carotid Endarterectomy Trial) percentage criterion. Results: The average annual progression rate for the 74 plaques included was 5.7% NASCET per year. We identified 18 plaques with ≥10% NASCET progression and 56 plaques without significant progression −1 [5813–8974] in plaques with progression and 6564 s−1 [5285–8766] in stable plaques (p=0.643). Median ELC was 3.86 m2 [2.78–5.53] in plaque with progression and 4.32 m2 [3.42–6.81] in stable plaques (p=0.296). Conclusions: Although it is a widely accepted hypothesis that shear stress and hemodynamics of the carotid bifurcation contribute to plaque progression, we found that WSR and ELC estimated by Doppler ultrasound do not reliably predict atherosclerotic plaque progression in the carotid artery. Other ultrasound modalities, such as 3D imaging, may be used to assess the influence of plaque geometry and hemodynamics in plaque progression.
- 1 July 2023
- Published by Hogrefe Publishing Group in Vasa
- Vol. 52 (4) , 249-256
Wall shear rate and energy loss coefficient measures using conventional Doppler ultrasound do not predict carotid plaque progression
Summary: Background: The rate of carotid plaque progression is believed to be related to blood flow hemodynamics and shear stress. Our objective was to determine if wall shear rate (WSR) and the energy loss coefficient (ELC) measured by Doppler ultrasound could predict atherosclerotic carotid disease progression. Patients and methods: Patients at a large tertiary center with an initial ultrasound between 2016 and 2018 with a significant carotid plaque were included if they had at least one 6 months follow-up comparative study. Stenosis progression was assessed according to the NASCET (The North American Symptomatic Carotid Endarterectomy Trial) percentage criterion. Results: The average annual progression rate for the 74 plaques included was 5.7% NASCET per year. We identified 18 plaques with ≥10% NASCET progression and 56 plaques without significant progression −1 [5813–8974] in plaques with progression and 6564 s−1 [5285–8766] in stable plaques (p=0.643). Median ELC was 3.86 m2 [2.78–5.53] in plaque with progression and 4.32 m2 [3.42–6.81] in stable plaques (p=0.296). Conclusions: Although it is a widely accepted hypothesis that shear stress and hemodynamics of the carotid bifurcation contribute to plaque progression, we found that WSR and ELC estimated by Doppler ultrasound do not reliably predict atherosclerotic plaque progression in the carotid artery. Other ultrasound modalities, such as 3D imaging, may be used to assess the influence of plaque geometry and hemodynamics in plaque progression.
- Open Access
- 20 March 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (2) , 100065
Osteoprotegerin deficiency and aneurysm formation: Case report of iliac artery aneurysms in Juvenile Paget's disease
- 20 March 2022
- Published by Elsevier in Annals of Vascular Surgery - Brief Reports and Innovations
- Vol. 2 (2) , 100065
Open AccessOsteoprotegerin deficiency and aneurysm formation: Case report of iliac artery aneurysms in Juvenile Paget's disease
- 17 February 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (1) , 011008
Inductive Sensing to Detect Tissue Thickness Between Magnets for Potential Application in Magnetic Compression Based Anastomosis
Magnetic compression based anastomoses use magnetic force to necrose tissue between two magnets to create an anastomosis. Nickel-plated neodymium–iron–boron magnets are used in our study. The compression pressure between the magnets depends on the distance between the magnets, which is determined by the thickness of the compressed tissue and depends on bowel wall thickness and elasticity. It is critical to know the distance between the magnets once the tissue is compressed because the magnets must be within a critical distance of each other in order to create enough compressive force to necrose the tissue. We have developed an inductance sensor to detect the distance (tissue thickness) between the two magnets after the surgeon has deployed them. Inductance sensing is a contact-less sensing method that enables precise short-range detection of conducting surfaces. The inductor coil mounted on one magnet detects the second magnet by measuring the change in inductance due to eddy current induced on the nickel-plated surface of the second magnet. The change in the inductance is proportional to the change in distance between the magnets. The sensor was first calibrated by using polycarbonate sheets to simulate the intestine tissue. We are able to detect up to 6 mm of spacing between the magnets. Pig intestine from Yorkshire pigs was used to characterize the sensor. We are able to distinguish up to five distinct layers of the intestine from the large intestine. This sensing mechanism can indicate the operating surgeon the exact thickness of the tissue compressed between the two magnets. The surgeon can thus be sure of formation of a clean anastomosis and avoid the likelihood of the magnets sliding away or uncoupling.
- 17 February 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (1) , 011008
Inductive Sensing to Detect Tissue Thickness Between Magnets for Potential Application in Magnetic Compression Based Anastomosis
Magnetic compression based anastomoses use magnetic force to necrose tissue between two magnets to create an anastomosis. Nickel-plated neodymium–iron–boron magnets are used in our study. The compression pressure between the magnets depends on the distance between the magnets, which is determined by the thickness of the compressed tissue and depends on bowel wall thickness and elasticity. It is critical to know the distance between the magnets once the tissue is compressed because the magnets must be within a critical distance of each other in order to create enough compressive force to necrose the tissue. We have developed an inductance sensor to detect the distance (tissue thickness) between the two magnets after the surgeon has deployed them. Inductance sensing is a contact-less sensing method that enables precise short-range detection of conducting surfaces. The inductor coil mounted on one magnet detects the second magnet by measuring the change in inductance due to eddy current induced on the nickel-plated surface of the second magnet. The change in the inductance is proportional to the change in distance between the magnets. The sensor was first calibrated by using polycarbonate sheets to simulate the intestine tissue. We are able to detect up to 6 mm of spacing between the magnets. Pig intestine from Yorkshire pigs was used to characterize the sensor. We are able to distinguish up to five distinct layers of the intestine from the large intestine. This sensing mechanism can indicate the operating surgeon the exact thickness of the tissue compressed between the two magnets. The surgeon can thus be sure of formation of a clean anastomosis and avoid the likelihood of the magnets sliding away or uncoupling.