KBKarine Baassiri

Karine Baassiri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karine Baassiri has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Understanding the Impact of Synthetic Hematocrit Levels and Biomimetic Channel Widths on Bubble Parameters in Vascular Systems on a Chip

    by Karine Baassiri, Dan V. Nicolau

    Gas embolism is a rare but life-threatening process characterized by the presence of gas bubbles in the venous or arterial systems. These bubbles, if sufficiently large or numerous, can block the delivery of oxygen to critical organs, in particular the brain, and subsequently they can trigger a cascade of adverse biochemical reactions with severe medical outcomes. Despite its critical nature, gas embolism remains poorly understood, necessitating extensive investigation, particularly regarding its manifestations in the human body and its modulation by various biological conditions. However, given its elusive nature, as well as potential lethality, gas embolism is extremely difficult to study in vivo, and nearly impossible to be the subject of clinical trials. To this end, we developed a microfluidic device designed to study in vitro the impact of blood properties and vascular geometries on the formation and evolution of gas bubbles. The system features a biomimetic vascular channel surrounded by two pressure chambers, which induce the genesis of bubbles under varying circumstances. The bubble parameters were correlated with different input parameters, i.e., channel widths, wall thicknesses, viscosities of the artificial blood, and pressure levels. Smaller channel widths and higher equivalent hematocrit concentrations in synthetic blood solutions increased the nucleation density and bubble generation frequencies. Small channel widths were also more prone to bubble formation, with implications for the vulnerability of vascular walls, leading to increased risks of damage or compromise to the integrity of the blood vessels. Larger channel widths, along with higher equivalent hematocrit concentrations, translated into larger bubble volumes and decreased bubble velocities, leading to an increased risk of bubble immobilization within the blood vessels. This biomimetic approach provides insights into the impact of patient history and biological factors on the incidence and progression of gas embolism. Medical conditions, such as anemia, along with anatomical features related to age and sex—such as smaller blood vessels in women and children or larger vascular widths in adult men—affect the susceptibility to the initiation and progression of gas embolism, explored here in vitro through the development of a controlled, physiological-like environment. The analysis of the videos that recorded gas embolism events in vitro for systems where pressure is applied laterally on the microvasculature with thin walls, i.e., 50 μm or less, suggests that the mechanism of gas transfer for the pressure area to the blood is based on percolation, rather than diffusion. These findings highlight the importance of personalized approaches in the management and prevention of gas embolism.


  • Open Access

    Hydrophobic Recovery of PDMS Surfaces in Contact with Hydrophilic Entities: Relevance to Biomedical Devices

    by Tomoo Tsuzuki, Karine Baassiri, Zahra Mahmoudi, Ayyappasamy Sudalaiyadum Perumal, Kavya Rajendran, Gala Montiel Rubies, Dan V. Nicolau

    Polydimethylsiloxane (PDMS), a silicone elastomer, is increasingly being used in health and biomedical fields due to its excellent optical and mechanical properties. Its biocompatibility and resistance to biodegradation led to various applications (e.g., lung on a chip replicating blood flow, medical interventions, and diagnostics). The many advantages of PDMS are, however, partially offset by its inherent hydrophobicity, which makes it unsuitable for applications needing wetting, thus requiring the hydrophilization of its surface by exposure to UV or O2 plasma. Yet, the elastomeric state of PDMS translates in a slow, hours to days, process of reducing its surface hydrophilicity—a process denominated as hydrophobic recovery. Using Fourier transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM), the present study details the dynamics of hydrophobic recovery of PDMS, on flat bare surfaces and on surfaces embedded with hydrophilic beads. It was found that a thin, stiff, hydrophilic, silica film formed on top of the PDMS material, following its hydrophilization by UV radiation. The hydrophobic recovery of bare PDMS material is the result of an overlap of various nano-mechanical, and diffusional processes, each with its own dynamics rate, which were analyzed in parallel. The hydrophobic recovery presents a hysteresis, with surface hydrophobicity recovering only partially due to a thin, but resilient top silica layer. The monitoring of hydrophobic recovery of PDMS embedded with hydrophilic beads revealed that this is delayed, and then totally stalled in the few-micrometer vicinity of the embedded hydrophilic beads. This region where the hydrophobic recovery stalls can be used as a good approximation of the depth of the resilient, moderately hydrophilic top layer on the PDMS material. The complex processes of hydrophilization and subsequent hydrophobic recovery impact the design, fabrication, and operation of PDMS materials and devices used for diagnostics and medical procedures. Consequently, especially considering the emergence of new surgical procedures using elastomers, the impact of hydrophobic recovery on the surface of PDMS warrants more comprehensive studies.