Hazel J. Evans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hazel J. Evans has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Martin Samuels
Department of Respiratory Medicine, Great Ormond Street Hospital, London, UK
5 shared publications - Catherine Mary Hill
Faculty of Medicine, University of Southampton, Southampton, UK
3 shared publications Ho Ming Yuen
Faculty of Medicine, University of Southampton, Southampton, UK
3 shared publicationsJohanna Gavlak
University Hospital Southampton NHS Foundation Trust, Southampton, UK
3 shared publicationsJonathan James
Paediatric Respiratory Medicine, University Hospital Southampton NHS Foundation Trust, Southampton, UK
3 shared publications- Neil Gibson
Royal Hospital for Children, Glasgow, UK
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by European Respiratory Society (ERS) in ERJ Open Research
Prospective validation of a wearable device for automated paediatric OSA diagnosis
Background: Obstructive sleep apnoea (OSA) is common in children and associated with significant childhood morbidity. The current reference standards for paediatric OSA diagnosis are attended polysomnography (PSG) and cardio-respiratory polygraphy (CR-PG) - both resource-intensive and access-limited. No fully-automated diagnostic device has previously been prospectively validated against PSG or CR-PG. Methods: Prospective, blinded, multicentre diagnostic-accuracy study at two UK tertiary paediatric centres. Consecutive children referred for suspected OSA were studied overnight by attended in-hospital paediatric sleep study (reference standard PSG or CR-PG, scored per AASM paediatric rules) and by AcuPebble SA100, a wearable sensor producing an automated diagnosis, set up by carers who also completed a usability questionnaire. Results: 141 children had valid data (median age 7.1 years, range 1.2–17.3 years; 88.7% with comorbidities; 36.2% with learning difficulties). For moderate-or-severe OSA (OAHI ≥5·h −1 ), AcuPebble achieved sensitivity 100% (95%-CI 80.49–100), specificity 96.77%, accuracy 97.16%, positive predictive value 80.95%, negative predictive value 100%, and positive likelihood ratio 31.0. Performance was similar on the broader AHI (additionally capturing central events): sensitivity 94.12%, specificity 98.13%, positive likelihood ratio 50.4. Among surveyed carers, 97.0% completed setup unassisted; 81.9% rated AcuPebble as more comfortable than conventional sensors; only 10.5% would prefer PSG/CR-PG. Conclusions: Automated diagnosis of paediatric OSA with AcuPebble met recommended diagnostic-accuracy thresholds. Carer-led setup was feasible and acceptable, supporting the device's use as an alternative to attended in-hospital sleep studies. Performance was maintained in a complex tertiary-referral cohort, where sleep studies are most difficult to deliver.
- 1 October 2026
- Published by European Respiratory Society (ERS) in ERJ Open Research
Open AccessProspective validation of a wearable device for automated paediatric OSA diagnosis
Background: Obstructive sleep apnoea (OSA) is common in children and associated with significant childhood morbidity. The current reference standards for paediatric OSA diagnosis are attended polysomnography (PSG) and cardio-respiratory polygraphy (CR-PG) - both resource-intensive and access-limited. No fully-automated diagnostic device has previously been prospectively validated against PSG or CR-PG. Methods: Prospective, blinded, multicentre diagnostic-accuracy study at two UK tertiary paediatric centres. Consecutive children referred for suspected OSA were studied overnight by attended in-hospital paediatric sleep study (reference standard PSG or CR-PG, scored per AASM paediatric rules) and by AcuPebble SA100, a wearable sensor producing an automated diagnosis, set up by carers who also completed a usability questionnaire. Results: 141 children had valid data (median age 7.1 years, range 1.2–17.3 years; 88.7% with comorbidities; 36.2% with learning difficulties). For moderate-or-severe OSA (OAHI ≥5·h −1 ), AcuPebble achieved sensitivity 100% (95%-CI 80.49–100), specificity 96.77%, accuracy 97.16%, positive predictive value 80.95%, negative predictive value 100%, and positive likelihood ratio 31.0. Performance was similar on the broader AHI (additionally capturing central events): sensitivity 94.12%, specificity 98.13%, positive likelihood ratio 50.4. Among surveyed carers, 97.0% completed setup unassisted; 81.9% rated AcuPebble as more comfortable than conventional sensors; only 10.5% would prefer PSG/CR-PG. Conclusions: Automated diagnosis of paediatric OSA with AcuPebble met recommended diagnostic-accuracy thresholds. Carer-led setup was feasible and acceptable, supporting the device's use as an alternative to attended in-hospital sleep studies. Performance was maintained in a complex tertiary-referral cohort, where sleep studies are most difficult to deliver.
- 8 September 2026
- Published by BMJ in Archives of Disease in Childhood
Clinically significant night-to-night variability in overnight oximetry screening for obstructive sleep apnoea in children with Down syndrome: a retrospective review of screening data
Aim: To understand the extent and implications of night-to-night variability (NTNV) in obstructive sleep apnoea (OSA) screening for children with Down syndrome (DS). Design: Retrospective review of outpatient OSA screening data, assessing NTNV across three consecutive nights of pulse oximetry (3NPO) studies and comparing results of screening oximetry and diagnostic polygraphy (PG). Two hundred and forty-six 3NPO studies in patients aged 1 to 6 years. Conclusions: Clinically significant NTNV was seen in the majority of 3NPO studies. Single-night screening may miss children who would screen positive on multiple-night testing. UK screening recommendations may need revision to reflect NTNV and significant OSA prevalence in older children.
- 8 September 2026
- Published by BMJ in Archives of Disease in Childhood
Clinically significant night-to-night variability in overnight oximetry screening for obstructive sleep apnoea in children with Down syndrome: a retrospective review of screening data
Aim: To understand the extent and implications of night-to-night variability (NTNV) in obstructive sleep apnoea (OSA) screening for children with Down syndrome (DS). Design: Retrospective review of outpatient OSA screening data, assessing NTNV across three consecutive nights of pulse oximetry (3NPO) studies and comparing results of screening oximetry and diagnostic polygraphy (PG). Two hundred and forty-six 3NPO studies in patients aged 1 to 6 years. Conclusions: Clinically significant NTNV was seen in the majority of 3NPO studies. Single-night screening may miss children who would screen positive on multiple-night testing. UK screening recommendations may need revision to reflect NTNV and significant OSA prevalence in older children.
- 15 April 2026
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
Investigating variations and early-life temporal changes in oxygen saturation indices in healthy moderate-late preterm and term infants: a cohort study
Background: Neonatal respiratory system immaturity causes unstable breathing patterns during sleep, resulting in respiratory events and intermittent hypoxaemia (IH). The recent literature correlates frequent respiratory events with adverse early neurodevelopmental outcomes. Aims: This study investigated 5-week temporal changes in oxygen saturation indices in healthy moderate-late preterm (MLPT) (born between 32+0 weeks and 36+6 weeks of gestation) and term (born between 37+0 weeks and 41+6 weeks of gestation) infants. Methods: MLPT and term infants’ sleeping postductal saturations were measured using nocturnal pulse oximetry at 7 days, 14 days, 21 days, 28 days and 35 days (±3 days) postnatal age. This recorded mean peripheral oxygen saturation (SpO 2 ), Oxygen Desaturation Indices (ODIs) 3, 4 and 10 (number of desaturations >3%, >4% and >10% per hour) and mean nadir SpO 2 >3%. Results: 34 infants were studied (17 per group). The groups’ median gestations were 35+0 weeks and 39+5 weeks, respectively. Generalised linear mixed modelling indicated increasing mean saturations from 94.98% in week 1 to 96.68% in week 5 (p3% was 89.94% versus 91.55% for term infants (p=0.005), with both groups improving throughout the study (p=0.006). MLPT infants had 2.08 times more ODI3 dips/hour (p<0.001), 2.49 times more ODI4 dips/hour (p<0.001) and 6.66 times more ODI10 dips/hour (p=0.005) than term infants. Conclusion: This study demonstrated significant differences in IH prevalence and severity between groups. Further research is needed to evaluate IH’s impact on neurodevelopmental outcomes in this population.
- 15 April 2026
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
Investigating variations and early-life temporal changes in oxygen saturation indices in healthy moderate-late preterm and term infants: a cohort study
Background: Neonatal respiratory system immaturity causes unstable breathing patterns during sleep, resulting in respiratory events and intermittent hypoxaemia (IH). The recent literature correlates frequent respiratory events with adverse early neurodevelopmental outcomes. Aims: This study investigated 5-week temporal changes in oxygen saturation indices in healthy moderate-late preterm (MLPT) (born between 32+0 weeks and 36+6 weeks of gestation) and term (born between 37+0 weeks and 41+6 weeks of gestation) infants. Methods: MLPT and term infants’ sleeping postductal saturations were measured using nocturnal pulse oximetry at 7 days, 14 days, 21 days, 28 days and 35 days (±3 days) postnatal age. This recorded mean peripheral oxygen saturation (SpO 2 ), Oxygen Desaturation Indices (ODIs) 3, 4 and 10 (number of desaturations >3%, >4% and >10% per hour) and mean nadir SpO 2 >3%. Results: 34 infants were studied (17 per group). The groups’ median gestations were 35+0 weeks and 39+5 weeks, respectively. Generalised linear mixed modelling indicated increasing mean saturations from 94.98% in week 1 to 96.68% in week 5 (p3% was 89.94% versus 91.55% for term infants (p=0.005), with both groups improving throughout the study (p=0.006). MLPT infants had 2.08 times more ODI3 dips/hour (p<0.001), 2.49 times more ODI4 dips/hour (p<0.001) and 6.66 times more ODI10 dips/hour (p=0.005) than term infants. Conclusion: This study demonstrated significant differences in IH prevalence and severity between groups. Further research is needed to evaluate IH’s impact on neurodevelopmental outcomes in this population.
- 11 August 2025
- Published by BMJ in Archives of Disease in Childhood
- Vol. 111 (1) , 27-34
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in children with Down syndrome: a dual-centre study
Background and objective: Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is cheaper and more accessible. This study evaluates NPO indices’ ability to predict OSA in children with Down syndrome (DS). Methods: Indices from simultaneous NPO and CRP recordings were compared in children with DS (aged 2–16 years) referred to evaluate OSA in two tertiary centres across an 8-year period. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices, including ODI3 (3% Oxygen Desaturation Index) and ODI4 (4% Oxygen Desaturation Index). Two-by-two tables determined the sensitivities and specificities of cut-off values for predicting OSA. Results: 387 children with DS were included with stand-alone NPO; 177 female (46.7%), median age 6.1 years (range 2.02–15.97). There were 265 children (68.5%) with Obstructive Apnoea–Hypopnoea Index (OAHI) ≥1/hour, 164 with OAHI ≥1<5/hour (42.4%), 51 with OAHI ≥5<10/hour (13.2%) and 50 with OAHI ≥10/hour (12.9%). ODI3 and ODI4 demonstrated the best predictive value for predicting OSA. An ODI3 ≥19/hour and an ODI4 ≥8/hour were associated with the highest combined sensitivity (59.2%/63.8%) and specificity (74.6%/71.3%), respectively. Conclusion: Raised ODI3 and ODI4 predict moderate and severe OSA in children with DS with moderate specificity/sensitivity and have a low sensitivity for detecting mild OSA. The poor predictive performance of oximetry reflects the multifactorial nature of sleep disordered breathing in children with DS. We recommend oximetry is not used for diagnosis of OSA in DS and CRP/polysomnography should be used.
- 11 August 2025
- Published by BMJ in Archives of Disease in Childhood
- Vol. 111 (1) , 27-34
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in children with Down syndrome: a dual-centre study
Background and objective: Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is cheaper and more accessible. This study evaluates NPO indices’ ability to predict OSA in children with Down syndrome (DS). Methods: Indices from simultaneous NPO and CRP recordings were compared in children with DS (aged 2–16 years) referred to evaluate OSA in two tertiary centres across an 8-year period. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices, including ODI3 (3% Oxygen Desaturation Index) and ODI4 (4% Oxygen Desaturation Index). Two-by-two tables determined the sensitivities and specificities of cut-off values for predicting OSA. Results: 387 children with DS were included with stand-alone NPO; 177 female (46.7%), median age 6.1 years (range 2.02–15.97). There were 265 children (68.5%) with Obstructive Apnoea–Hypopnoea Index (OAHI) ≥1/hour, 164 with OAHI ≥1<5/hour (42.4%), 51 with OAHI ≥5<10/hour (13.2%) and 50 with OAHI ≥10/hour (12.9%). ODI3 and ODI4 demonstrated the best predictive value for predicting OSA. An ODI3 ≥19/hour and an ODI4 ≥8/hour were associated with the highest combined sensitivity (59.2%/63.8%) and specificity (74.6%/71.3%), respectively. Conclusion: Raised ODI3 and ODI4 predict moderate and severe OSA in children with DS with moderate specificity/sensitivity and have a low sensitivity for detecting mild OSA. The poor predictive performance of oximetry reflects the multifactorial nature of sleep disordered breathing in children with DS. We recommend oximetry is not used for diagnosis of OSA in DS and CRP/polysomnography should be used.
- 22 January 2024
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (4) , 308-313
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in typically developing children: a multicentre study
Background and objective Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is, however, cheaper and more accessible. This study evaluated the ability of NPO indices to predict OSA in typically developing (TD) children. Methods Indices from simultaneous NPO and CRP recordings were compared in TD children (aged 1–16 years) referred to evaluate OSA in three tertiary centres. OSA was defined as an obstructive apnoea–hypopnoea index (OAHI) ≥1 event/hour. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices including ODI3 (3% Oxygen Desaturation Index, ODI4 (4% Oxygen Desaturation Index), delta 12 s index and minimum oxygen saturation. Two-by-two tables were generated to determine the sensitivities and specificities of whole number cut-off values for predicting OAHIs ≥1, 5 and 10 events/hour. Results Recordings from 322 TD children, 197 male (61.2%), median age 4.9 years (range 1.1–15.6), were reviewed. OAHI was ≥1/hour in 144 (44.7%), ≥5/hour in 61 (18.9%) and ≥10/hour in 28 (8.7%) cases. ODI3 and ODI4 had the best diagnostic accuracy. ODI3 ≥7/hour and ODI4 ≥4/hour predicted OSA in TD children with sensitivities/specificities of 57.6%/85.4% and 46.2%/91.6%, respectively. ODI3 ≥8/hour was the best predictor of OAHI ≥5/hour (sensitivity 82.0%, specificity 84.3%). Conclusion Raised ODI3 and ODI4 predict OSA in TD children with high specificity but variable sensitivity. NPO may be an alternative to diagnose moderate-severe OSA if access to CRP is limited. Low sensitivities to detect mild OSA mean that confirmatory CRP is needed if NPO is normal.
- 22 January 2024
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (4) , 308-313
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in typically developing children: a multicentre study
Background and objective Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is, however, cheaper and more accessible. This study evaluated the ability of NPO indices to predict OSA in typically developing (TD) children. Methods Indices from simultaneous NPO and CRP recordings were compared in TD children (aged 1–16 years) referred to evaluate OSA in three tertiary centres. OSA was defined as an obstructive apnoea–hypopnoea index (OAHI) ≥1 event/hour. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices including ODI3 (3% Oxygen Desaturation Index, ODI4 (4% Oxygen Desaturation Index), delta 12 s index and minimum oxygen saturation. Two-by-two tables were generated to determine the sensitivities and specificities of whole number cut-off values for predicting OAHIs ≥1, 5 and 10 events/hour. Results Recordings from 322 TD children, 197 male (61.2%), median age 4.9 years (range 1.1–15.6), were reviewed. OAHI was ≥1/hour in 144 (44.7%), ≥5/hour in 61 (18.9%) and ≥10/hour in 28 (8.7%) cases. ODI3 and ODI4 had the best diagnostic accuracy. ODI3 ≥7/hour and ODI4 ≥4/hour predicted OSA in TD children with sensitivities/specificities of 57.6%/85.4% and 46.2%/91.6%, respectively. ODI3 ≥8/hour was the best predictor of OAHI ≥5/hour (sensitivity 82.0%, specificity 84.3%). Conclusion Raised ODI3 and ODI4 predict OSA in TD children with high specificity but variable sensitivity. NPO may be an alternative to diagnose moderate-severe OSA if access to CRP is limited. Low sensitivities to detect mild OSA mean that confirmatory CRP is needed if NPO is normal.
- 8 November 2023
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (1) , 74-75
To define reference ranges for the 3% and 4% mean desaturation nadir in healthy children under 12 years: observational study using oximetry motion-resistant technology
- 8 November 2023
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (1) , 74-75
To define reference ranges for the 3% and 4% mean desaturation nadir in healthy children under 12 years: observational study using oximetry motion-resistant technology
- Open Access
- 4 August 2023
- Published by Springer Nature in Pediatric Research
- Vol. 94 (6) , 2062-2069
Longitudinal pilot study of oxygen saturation indices in healthy preterm infants
Background: This study aimed to determine patterns of nocturnal pulse oximetry indices in moderate to late preterm infants, and investigate the relationship between oxygen desaturations, the apnoea hypopnoea index, and both corrected gestational and postnatal age. Methods: 21 healthy infants born at 32 + 0 - 36 + 6 weeks gestation underwent serial nocturnal pulse oximetry studies and respiratory polygraphy studies until 40 weeks corrected gestational age (CGA). The main outcome measures were number of >3% oxygen desaturations/hour (ODI3), mean oxygen saturations, and number of apnoeas and hypopnoeas/hour. Results: Median ODI3 increased between weeks 1 and 3 from 49.9 to 85.4/hour (p = 0.017). Mean oxygen saturations reached a corresponding nadir of 96.0% in week 3, then increased to 96.8% in week 6 (p = 0.019). Mixed effects modelling demonstrated that ODI3 and mean saturations were influenced by postnatal age but not CGA (p < 0.05). Desaturations frequently occurred without an apnoea or hypopnoea. Conclusion: ODI3 rises then falls during the first 8 weeks of life in moderate to late preterm infants, independently of CGA. These interesting preliminary results highlight the importance of further serial data collection to generate age-specific normal ranges, and develop a better understanding of respiratory control in preterm infants. Impact: The frequency of >3% oxygen desaturations (ODI3) in healthy moderate to late preterm infants rises then falls after birth, peaking in postnatal week 3. There is a corresponding nadir in mean saturations. There were significant non-linear relationships between ODI3/mean saturations and postnatal age, but not corrected gestational age. The majority of brief oxygen desaturations occurred without an apnoea or hypopnoea. Normal ranges for oxygen saturation indices are not known in this population. These results demonstrate the need for further serial data collection to generate age-specific normal ranges and inform oxygen prescribing guidelines.
- 4 August 2023
- Published by Springer Nature in Pediatric Research
- Vol. 94 (6) , 2062-2069
Open AccessLongitudinal pilot study of oxygen saturation indices in healthy preterm infants
Background: This study aimed to determine patterns of nocturnal pulse oximetry indices in moderate to late preterm infants, and investigate the relationship between oxygen desaturations, the apnoea hypopnoea index, and both corrected gestational and postnatal age. Methods: 21 healthy infants born at 32 + 0 - 36 + 6 weeks gestation underwent serial nocturnal pulse oximetry studies and respiratory polygraphy studies until 40 weeks corrected gestational age (CGA). The main outcome measures were number of >3% oxygen desaturations/hour (ODI3), mean oxygen saturations, and number of apnoeas and hypopnoeas/hour. Results: Median ODI3 increased between weeks 1 and 3 from 49.9 to 85.4/hour (p = 0.017). Mean oxygen saturations reached a corresponding nadir of 96.0% in week 3, then increased to 96.8% in week 6 (p = 0.019). Mixed effects modelling demonstrated that ODI3 and mean saturations were influenced by postnatal age but not CGA (p < 0.05). Desaturations frequently occurred without an apnoea or hypopnoea. Conclusion: ODI3 rises then falls during the first 8 weeks of life in moderate to late preterm infants, independently of CGA. These interesting preliminary results highlight the importance of further serial data collection to generate age-specific normal ranges, and develop a better understanding of respiratory control in preterm infants. Impact: The frequency of >3% oxygen desaturations (ODI3) in healthy moderate to late preterm infants rises then falls after birth, peaking in postnatal week 3. There is a corresponding nadir in mean saturations. There were significant non-linear relationships between ODI3/mean saturations and postnatal age, but not corrected gestational age. The majority of brief oxygen desaturations occurred without an apnoea or hypopnoea. Normal ranges for oxygen saturation indices are not known in this population. These results demonstrate the need for further serial data collection to generate age-specific normal ranges and inform oxygen prescribing guidelines.
- 6 June 2023
- Published by BMJ in Archives of Disease in Childhood - Education & Practice Edition
- Vol. 108 (6) , 429-438
Use of pulse oximetry as an investigative test for paediatric respiratory sleep disorders
The article covers the following elements: practical and technological considerations for optimising data collection and output; reference ranges for oximetry parameters across the ages; things to consider when interpreting a pulse oximetry study (eg, sleep/wake times); the ability of pulse oximetry to predict obstructive sleep apnoea; using oximetry as a screening tool for sleep disordered breathing in children with Down syndrome; things to consider when setting up a home oximetry service; and a case of an infant being weaned from oxygen using pulse oximetry studies.
- 6 June 2023
- Published by BMJ in Archives of Disease in Childhood - Education & Practice Edition
- Vol. 108 (6) , 429-438
Use of pulse oximetry as an investigative test for paediatric respiratory sleep disorders
The article covers the following elements: practical and technological considerations for optimising data collection and output; reference ranges for oximetry parameters across the ages; things to consider when interpreting a pulse oximetry study (eg, sleep/wake times); the ability of pulse oximetry to predict obstructive sleep apnoea; using oximetry as a screening tool for sleep disordered breathing in children with Down syndrome; things to consider when setting up a home oximetry service; and a case of an infant being weaned from oxygen using pulse oximetry studies.